{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1154F7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1154F7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1154F7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1154F7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F1154F7, 4-pole contactor, 200 A AC-1, 110 V AC coil, plate mount.","salesMarkdown":"It carries 200 A at ≤440 V (at <40 °C) across four normally-open power poles, making it a fit for large heating banks, furnace control, or high-current resistive bus transfer where the load doesn't draw an inrush spike. The 110 V AC control coil (40–400 Hz) pulls 770 VA inrush and holds at 8.1 VA — the drop-out threshold sits between 0.2 and 0.55 Uc, so expect it to release cleanly on a sagging line without nuisance chatter. This contactor is not rated for AC-3 motor starting or AC-4 plugging — if your BOM calls for motor switching, you need a different TeSys F variant with the AC-3 curve. The 4 NO pole configuration means all four contacts close together; there are no NC auxiliaries built in, so plan for an external auxiliary block if you need a status feedback signal. The 920 A rated breaking capacity per IEC 60947-4-1 confirms it can interrupt a fault without welding the main contacts, but the associated fuse recommendation (125 A aM or 200 A gG at ≤440 V) sets the upstream protection limit — don't oversize the fuse beyond that or the contactor becomes the weak link in a short-circuit event. This part is end-of-life (EOL) per the manufacturer's lifecycle stage. Plate-mounted — no DIN rail adapter on this frame size. The 200.5 mm width, 162 mm height, and 171 mm depth need panel layout planning; it's a substantial block. Power connections accept bar (20 x 3 mm busbar), ring lugs, or bolted connections for up to 95 mm² cable. Control wiring uses screw-clamp terminals accepting 1–4 mm² solid or flexible. Tightening torque: 10 N·m on the power circuit, 1.2 N·m on the control circuit. The IP2X front face with shrouds meets finger-probe protection per IEC 60529 and VDE 0106 — fine for a closed panel but not for washdown environments. Altitude rating of 3000 m without derating covers most installations outside high-mountain sites. Heat dissipation runs 5.9–7.2 W total (15 W per pole in AC-1), which matters for panel thermal budgeting — don't cluster multiple units without airflow. The TH protective treatment adds tropicalisation for humid or corrosive environments.","metaTitle":"Schneider Electric LC1F1154F7 TeSys F Contactor, 200 A AC-1,","metaDescription":"Schneider Electric LC1F1154F7 TeSys F contactor, 200 A rated operational current at ≤440 V AC-1, 4 NO poles, 110 V AC 40-400 Hz coil. End of life — sourced to order against RFQ. Qu","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"200.5 mm","Height":"162 mm","Standards":"EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1","Operating time":"35 ms closing (at Uc) 130 ms opening (at Uc)","lifecycle_stage":"eol_hot","Heat dissipation":"5.9...7.2 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"4P","Tightening torque":"Power circuit: 10 N.m Control circuit: 1.2 N.m","Compatibility code":"LC1F","Inrush power in VA":"770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1","[Uc] control circuit voltage":"110 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"200 A (at <40 °C) at <= 440 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min","[Ith] conventional free air thermal current":"200 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/695ca2a7c801156fab2ac7e8f3a243d3.pdf","sourceUrl":"https://www.se.com/hk/en/product/LC1F1154F7/tesys-f-contactor-4p-4-no-ac1-440-v-200-a-coil-110-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1154F7/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LC1F1154F7 and how is it quoted?","answer":"The LC1F1154F7 is sourced to order against an RFQ through independent distribution and surplus channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time check."},{"question":"What compliance documentation does Schneider provide for LC1F1154F7?","answer":"The LC1F1154F7 is certified to IEC 60947-4-1, EN 60947-1, and JIS C8201-4-1. No RoHS, REACH, or UL statement appears in this record — request those specific declarations from the seller at RFQ time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1154F7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1154F7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}