{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1154R6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1154R6","canonicalUrl":"https://aoctrl.com/schneider/LC1F1154R6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1154R6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor, 4-pole, 200 A AC-1, 440 V AC 60 Hz coil, plate mount.","salesMarkdown":"## What the 200 A AC-1 rating means for your BOM The LC1F1154R6 is a 4-pole contactor from the TeSys F range, rated 200 A in AC-1 utilisation category at <= 440 V. AC-1 covers resistive loads — heaters, lighting banks, and non-inductive circuits — where the current inrush is minimal. The 200 A figure is the thermal current (Ith) the main poles can carry continuously; for motor duty (AC-3) you would need to derate significantly, so this part is not a first choice for switching induction motors. The 4 NO pole configuration gives you four normally-open power contacts, each rated for the full 200 A when paralleled or used independently on separate load legs. ## Coil and control circuit constraints The control circuit is AC at 60 Hz, rated 440 V. That is a non-standard coil voltage for many regions — 50 Hz installations or 230 V control transformers will not drive this contactor. The hold-in power consumption is 55 VA at 60 Hz, cos phi 0.3; inrush at pickup is 660 VA. The voltage limits are 0.85 to 1.1 Uc for pickup and 0.35 to 0.55 Uc for drop-out, both at 55 °C. If your panel runs a 50 Hz control bus, this coil will overheat or fail to seal — confirm the control voltage before specifying. Plate-mounted — no DIN rail adapter included. The 171 mm depth, 200.5 mm width, and 162 mm height require a backplate with clearance for the power circuit connections: bar or busbar up to 20 x 3 mm, or ring-terminal lugs for 95 mm² cable. Tightening torque on the power circuit is 10 N.m; control circuit screw clamps take 1.2 N.m. The front face with shrouds achieves IP2X per IEC 60529 and VDE 0106 — finger-safe but not sealed against moisture. For washdown or outdoor enclosures, the contactor itself needs a separate enclosure rated to the environment. ## Breaking capacity and protection coordination For short-circuit protection, the associated fuse ratings are 125 A aM or 200 A gG at <= 440 V. The rated impulse withstand voltage is 8 kV, and the insulation voltage is rated at 1000 V per IEC 60947-4-1 or 1500 V per VDE 0110 group C. ## Environmental and endurance specs Mechanical durability is 10 million cycles — the contactor body and armature are built for high-cycle applications like resistance welding or cyclic heater control. Maximum operating rate is 2400 cycles per hour at 55 °C. The TH protective treatment means it is tropicalised for humid or corrosive environments. Heat dissipation is 12 to 16 W total, with 15 W per pole in AC-1 duty — factor that into your enclosure thermal budget.","metaTitle":"Schneider Electric LC1F1154R6 TeSys F Contactor, 200 A AC-1,","metaDescription":"Schneider Electric LC1F1154R6 TeSys F contactor, 200 A rated operational current at <= 440 V AC-1, 4 NO poles, 440 V AC 60 Hz coil. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"200.5 mm","Height":"162 mm","Standards":"EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1","Operating time":"23...35 ms closing 5...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"12...16 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"4P","Tightening torque":"Power circuit: 10 N.m Control circuit: 1.2 N.m","Compatibility code":"LC1F","Inrush power in VA":"660 VA, 60 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 60 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1","[Uc] control circuit voltage":"440 V AC 60 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"200 A (at <40 °C) at <= 440 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"55 VA, 60 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min","[Ith] conventional free air thermal current":"200 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c5665fc82a3c3ba462c0727ccd173b83.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1F1154R6/tesys-f-contactor-4p-4-no-ac1-440-v-200-a-coil-440-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1154R6/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LC1F1154R6?","answer":"The LC1F1154R6 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock figure or lead-time number is carried on this listing."},{"question":"What is the rated operational current of LC1F1154R6?","answer":"The rated operational current is 200 A in AC-1 utilisation category at <= 440 V, at an ambient temperature below 40 °C. This is the continuous thermal current the main poles can carry for resistive loads."},{"question":"What control voltage does LC1F1154R6 require?","answer":"The control circuit is AC at 60 Hz, rated 440 V. The pickup voltage range is 0.85 to 1.1 Uc, and the drop-out range is 0.35 to 0.55 Uc, both at 55 °C. This coil is not compatible with 50 Hz or 230 V control systems."},{"question":"What standards does LC1F1154R6 comply with?","answer":"The LC1F1154R6 complies with EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, EN 60947-1, and JIS C8201-4-1. The rated breaking capacity of 920 A is confirmed per IEC 60947-4-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1154R6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1154R6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}