{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1154U7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1154U7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1154U7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1154U7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F1154U7, 4-pole contactor, 200 A AC-1 at ≤440 V, 240 VAC 40-400 Hz coil, plate mount.","salesMarkdown":"## TeSys F 4-pole contactor, 200 A AC-1 — EOL sourcing note The Schneider Electric LC1F1154U7 is a TeSys F 4-pole contactor rated 200 A in AC-1 utilisation category at ≤440 V, making it suited for switching resistive loads like heater banks or lighting in industrial panels. The coil is 240 V AC 40-400 Hz, with a closing time of 35 ms and opening at 130 ms at nominal voltage. This part is in end-of-life (EOL) phase per the manufacturer lifecycle status. The 200 A AC-1 rating at ≤440 V governs resistive loads — this is not a motor-starting (AC-3) contactor. For motor duty, the AC-1 figure would derate significantly; use the part only for the utilisation category stated. The 4 NO pole configuration (4 normally open power poles) suits applications requiring four independent load circuits, each rated for the full 200 A under AC-1 conditions. Heat dissipation runs 5.9 to 7.2 W total, with 15 W per pole in AC-1 duty — factor this into enclosure thermal calculations. The contactor is plate-mounted, not DIN-rail, so panel layout must accommodate bolted fixing. Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand of 8 kV. Overvoltage category III means it is suitable for fixed-installation distribution boards. The IP2X front-face protection (with shrouds) meets IEC 60529 and VDE 0106 for finger-safe touch protection. The LC1F1154U7 is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. It carries protective treatment TH for tropical environments. Ambient operating range is -40 to 60 °C, storage -60 to 80 °C, and altitude up to 3000 m without derating.","metaTitle":"Schneider Electric LC1F1154U7 TeSys F Contactor, 200 A AC-1,","metaDescription":"Schneider Electric LC1F1154U7 TeSys F 4-pole contactor. 200 A AC-1 at ≤440 V, 240 VAC coil. EOL phase; sourced to order against RFQ. IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"171 mm","Width":"200.5 mm","Height":"162 mm","Current":"200 A (at <40 °C) at <= 440 V AC-1","Voltage":"<= 460 V DC","Application":"Resistive load","Coil Voltage":"240 V AC 40...400 Hz","Operating Time":"35 ms closing at Uc) 130 ms opening at Uc)","Product Status":"End of Life","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Breaking Capacity":"920 A conforming to IEC 60947-4-1","Insulation Voltage Ui":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Temp Operating Max":"60 °C","Temp Operating Min":"-40 °C","Temperature Storage":"-60...80 °C","Control Circuit Type":"AC at 40...400 Hz","Utilization Category":"AC-1","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor","Ambient Air Temperature Operation":"-40...60 °C","Permissible Ambient Air Temperature Around The Device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c718ea4c7b3c113f0ee6b90a5f2fcf31.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F1154U7/tesys-f-contactor-4p-4-no-ac1-440-v-200-a-coil-240-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1154U7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1154U7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1154U7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}