{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1154V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1154V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1154V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1154V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F1154V7, 4-pole contactor, 200 A AC-1 at ≤440 V, 400 V AC 40-400 Hz coil, plate mount, EOL lifecycle stage.","salesMarkdown":"## TeSys F 4-pole contactor, 200 A AC-1 — lifecycle and fit The Schneider Electric LC1F1154V7 is a TeSys F series 4-pole contactor with 4 NO power poles, rated 200 A in AC-1 utilisation category at ≤440 V and <40 °C. That AC-1 rating means it is specified for resistive loads — heating elements, lighting banks, or transformer primary switching — where the current waveform stays near-sinusoidal with no motor inrush or inductive kick. The control coil is 400 V AC at 40-400 Hz, drawing 770 VA inrush and 8.1 VA hold-in power at 20 °C. The 200 A AC-1 rating governs continuous current-carrying capacity for resistive loads. The associated fuse recommendation is 125 A aM or 200 A gG at ≤440 V — a coordination pair that tells the panel builder what upstream protection keeps the contactor within its breaking capacity of 920 A per IEC 60947-4-1. Average impedance per pole is 0.37 mOhm at 200 A, 50 Hz, which translates to roughly 15 W dissipation per pole in AC-1 duty and 5.9-7.2 W total heat to manage inside the enclosure. Closing time is 35 ms and opening 130 ms at nominal control voltage. ## Mounting and integration into a panel Mounting is plate-based — no DIN-rail clip on this frame size. The footprint is 200.5 mm wide by 162 mm high by 171 mm deep. Power circuit connections accept bar or busbar up to 20 x 3 mm, lugs or connectors for 95 mm² cable, or bolted connection. Control circuit uses screw-clamp terminals accepting 1-4 mm² flexible or solid, with or without ferrules. Tightening torque is 10 N·m on the power circuit and 1.2 N·m on the control circuit. IP2X front-face protection with shrouds per IEC 60529 and VDE 0106 means finger-safe when shrouded — standard for a panel-mounted contactor where the front is accessible during commissioning or troubleshooting. Operating altitude is 3000 m without derating, and the ambient temperature range is -40 to 60 °C operating, -60 to 80 °C storage. The LC1F1154V7 is certified to EN 60947-1, IEC 60947-1, EN 60947-4-1, IEC 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Impulse withstand voltage is 8 kV, overvoltage category III. Protective treatment is TH for tropical environments. Compliance documentation (declarations of conformity, RoHS, REACH) is available from the manufacturer's documentation portal for the TeSys F series.","metaTitle":"Schneider Electric LC1F1154V7 TeSys F Contactor, 200 A AC-1,","metaDescription":"Schneider Electric LC1F1154V7 TeSys F contactor. 200 A rated operational current (AC-1, ≤440 V), 4 NO poles, 400 V AC coil. EOL lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"200.5 mm","Height":"162 mm","Standards":"EN 60947-1 IEC 60947-4-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-1","Operating time":"35 ms closing (at Uc) 130 ms opening (at Uc)","lifecycle_stage":"eol_hot","Heat dissipation":"5.9...7.2 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"4P","Tightening torque":"Power circuit: 10 N.m Control circuit: 1.2 N.m","Compatibility code":"LC1F","Inrush power in VA":"770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"200 A (at <40 °C) at <= 440 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min","[Ith] conventional free air thermal current":"200 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/875abcbeba65e7f33ffb6316a7bc2f1a.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1F1154V7/tesys-f-contactor-4p-4-no-ac1-440-v-200-a-coil-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1154V7/alternatives.json"},"ai":{"faq":[{"question":"What is the rated operational current of LC1F1154V7?","answer":"The LC1F1154V7 is rated 200 A in AC-1 utilisation category at ≤440 V and <40 °C, intended for resistive loads."},{"question":"What control coil voltage does LC1F1154V7 use?","answer":"The control coil is 400 V AC at 40-400 Hz, with an operational range of 0.85-1.1 Uc and drop-out at 0.2-0.55 Uc at 55 °C."},{"question":"Where can I buy LC1F1154V7?","answer":"As an EOL part, the LC1F1154V7 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What are the mounting dimensions of LC1F1154V7?","answer":"The LC1F1154V7 measures 200.5 mm wide by 162 mm high by 171 mm deep and is designed for plate mounting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1154V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1154V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}