{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F115B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F115B7","canonicalUrl":"https://aoctrl.com/schneider/LC1F115B7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F115B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, LC1F115B7, 3-pole contactor, 200 A AC-3 rated operational current, 55 kW at 400 V AC motor power, 24 V AC 50/60 Hz coil.","salesMarkdown":"## TeSys F 3-pole contactor — 200 A AC-3, 24 V AC coil The Schneider Electric LC1F115B7 is a TeSys F 3-pole contactor rated for 200 A in AC-3 duty at ≤ 440 V, switching motor loads up to 55 kW on a 400 V three-phase line. The 24 V AC control coil (40...400 Hz) pulls in at 0.85 to 1.1 Uc and drops out between 0.2 and 0.55 Uc — a wide dropout margin that helps avoid nuisance reclosing on a sagging control supply. Rated breaking capacity is 920 A per IEC 60947-4-1, and the contactor carries a rated insulation voltage of 1000 V (IEC) or 1500 V (VDE 0110 group C), with overvoltage category III — suitable for fixed-installation distribution panels and motor control centers. ## Motor power across common line voltages The AC-3 motor power table covers 30 kW at 230 V, 55 kW at 400 V, 59 kW at 415 V and 440 V, 75 kW at 500 V, and 80 kW at 690 V. For AC-4 duty, the contactor is rated 18.5 kW at 400 V. This contactor mounts to a plate (not DIN rail), so factor in the footprint: 6.4 in wide, 6.4 in tall, 6.7 in deep. Power connections accept bar (2 x 20 x 3 mm), ring terminals, or bolted connection up to 95 mm². Torque power terminals to 88.5 lbf·in (10 N·m) and control terminals to 10.6 lbf·in (1.2 N·m). The front face with shrouds provides IP2X finger protection per IEC 60529 and VDE 0106 — no additional guarding needed for basic touch safety in a closed panel. Operating temperature range is -40 to +140 °F (-40 to +60 °C), with storage down to -76 °F (-60 °C). Protective treatment is TH (tropicalized) for humid environments. Altitude rating is 3000 m without derating. Standards compliance includes IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1 — covering most global industrial installations. Associated fuse recommendations: 125 A aM or 200 A gG at ≤ 440 V.","metaTitle":"Schneider LC1F115B7 TeSys F Contactor, 200 A AC-3, 55 kW at","metaDescription":"Schneider Electric LC1F115B7 TeSys F 3-pole contactor, 200 A rated operational current AC-3, 55 kW motor power at 400 V AC. End-of-life status — sourced to order against RFQ. IEC 6","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"6.7 in (171 mm)","Range":"TeSys","Width":"6.4 in (163.3 mm)","Height":"6.4 in (162 mm)","Standards":"IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 EN 60947-1 JIS C8201-4-1","Motor power kW":"55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 30 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"35 ms closing at Uc) 130 ms opening at Uc)","lifecycle_stage":"eol_hot","Heat dissipation":"5.9...7.2 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Power circuit 88.5 lbf.in (10 N.m) Control circuit 10.6 lbf.in (1.2 N.m)","Compatibility code":"LC1F","Inrush power in VA":"690...855 VA, 40...400 Hz 0.9 68 °F (20 °C))","Operating altitude":"3000 m without derating","Control circuit type":"AC 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Power circuit bar 2 20 x 3 mm Power circuit lugs-ring terminals 1 0.1 in² (95 mm²) Power circuit connector 1 0.1 in² (95 mm²) Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bolted connection","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1 5 W AC-3","[Uc] control circuit voltage":"24 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.2...0.55 Uc 40...400 Hz 131 °F (55 °C))","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"200 A (at 115 A (at <131 °F (55 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"8.9...10.9 VA, 40...400 Hz 0.9 68 °F (20 °C))","Ambient air temperature for storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 104 °F (40 °C) - 10 s 640 A 104 °F (40 °C) - 30 s 520 A 104 °F (40 °C) - 1 min 400 A 104 °F (40 °C) - 3 min 320 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"200 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"140...158 °F (60...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6aef6921c348f88ce04dc57e4a6f763b.pdf","sourceUrl":"https://www.se.com/be/en/product/LC1F115B7/tesys-f-contactor-3p-3-no-ac3-440-v-115-a-coil-24-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F115B7/alternatives.json"},"ai":{"faq":[{"question":"What is the rated motor power of the LC1F115B7 at 400 V AC?","answer":"The LC1F115B7 is rated for 55 kW at 380...400 V AC in AC-3 duty. At 415 V it delivers 59 kW, at 440 V also 59 kW, at 500 V it reaches 75 kW, and at 660...690 V it delivers 80 kW."},{"question":"What control voltage does the LC1F115B7 use?","answer":"The LC1F115B7 uses a 24 V AC control coil rated for 40...400 Hz. The coil pulls in at 0.85 to 1.1 Uc and drops out between 0.2 and 0.55 Uc."},{"question":"Where can I buy the LC1F115B7?","answer":"The LC1F115B7 is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time."},{"question":"What standards does the LC1F115B7 comply with?","answer":"The LC1F115B7 complies with IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC and 1500 V per VDE 0110 group C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F115B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F115B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}