{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F115FE5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F115FE5","canonicalUrl":"https://aoctrl.com/schneider/LC1F115FE5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F115FE5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F115FE5, 3-pole contactor, 55 kW at 380-400 V AC AC-3, 200 A rated operational current, 115 V AC 50 Hz coil, plate mount.","salesMarkdown":"The Schneider Electric LC1F115FE5 is a 3-pole contactor from the TeSys F series, rated for motor control in AC-3 duty up to 55 kW at 380–400 V AC 50/60 Hz, with a rated operational current of 200 A at ≤440 V AC-3. It's built for panel-mount (plate mounting) and carries a 115 V AC 50 Hz control coil. The 55 kW AC-3 rating means it handles standard squirrel-cage motor starting — the load that matters for conveyor drives, pumps, and compressors in industrial panels. The 200 A frame also covers resistive loads (AC-1) and plugging/inching (AC-4) applications, though the AC-4 motor power drops to 18.5 kW at 400 V. ## Lifecycle reality — end-of-life status If you're planning a new panel or a long-term spares contract, the practical move is to qualify a current-production TeSys F replacement. The mechanical and electrical ratings (200 A frame, 55 kW AC-3, 115 VAC coil) define the cross-reference target. The 10 Mcycle mechanical durability and 2400 cycles/hour maximum operating rate set the endurance floor for the replacement. The associated fuse recommendation is 125 A aM or 200 A gG at ≤440 V. Heat dissipation runs 12–16 W total, with 5 W per pole in AC-3 and 15 W per pole in AC-1. That's the thermal load the enclosure has to shed; factor it into panel cooling calculations, especially in a sealed cabinet at 55 °C ambient. Dimensions are 162 mm high, 163.3 mm wide, 171 mm deep — a compact footprint for a 200 A frame, but it's a plate-mount part, not DIN-rail. The power terminals accept bar or busbar up to 20×3 mm, or ring lugs up to 95 mm². Control wiring uses screw clamps for 1–4 mm² solid or flexible.","metaTitle":"Schneider Electric LC1F115FE5 TeSys F Contactor, 55 kW AC-3,","metaDescription":"Schneider Electric LC1F115FE5 TeSys F contactor. 55 kW at 400V AC-3, 200 A rated current, 115 VAC 50 Hz coil. End-of-life status; sourced to order against RFQ. IEC/EN 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"163.3 mm","Height":"162 mm","Standards":"JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1","Motor power kW":"55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 30 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"23...35 ms closing 5...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"12...16 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Power circuit: 10 N.m Control circuit: 1.2 N.m","Compatibility code":"LC1F","Inrush power in VA":"550 VA, 50 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1 5 W AC-3","[Uc] control circuit voltage":"115 V AC 50 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"200 A (at 115 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"45 VA, 50 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min","[Ith] conventional free air thermal current":"200 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/537735441cdaed292f1d02598d5cea31.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1F115FE5/tesys-f-contactor-3p-3-no-ac3-440-v-115-a-coil-115-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F115FE5/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor power ratings for the LC1F115FE5?","answer":"In AC-3 duty, the LC1F115FE5 is rated for 55 kW at 380–400 V AC, 59 kW at 415 V and 440 V, 75 kW at 500 V, and 80 kW at 660–690 V. For AC-4 (plugging/inching), it's rated 18.5 kW at 400 V."},{"question":"What is the LC1F115FE5's rated operational current?","answer":"The rated operational current (Ie) is 200 A at ≤440 V in AC-3 duty, at 55 °C ambient."},{"question":"What standards does the LC1F115FE5 comply with?","answer":"It complies with IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 Group C."},{"question":"Where can I buy the LC1F115FE5?","answer":"The LC1F115FE5 is end-of-life, so it's sourced through independent surplus and broker channels. We can source it to order against an RFQ; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F115FE5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F115FE5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}