{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F115V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F115V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F115V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F115V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F115V7 3-pole contactor, 200 A AC-3 rated operational current, 400 V AC 40-400 Hz coil, plate mount.","salesMarkdown":"## What This Contactor Does — and What It Costs You in Setup Time The Schneider Electric LC1F115V7 is a 3-pole TeSys F contactor with a 400 V AC coil, rated 200 A in AC-3 duty at ≤440 V. The part is marked end-of-life (EOL) by the manufacturer, so it's not coming off the production line. The IEC 60947-4-1 and EN 60947-4-1 standards it conforms to are the ones that govern contactors and motor starters — that's your selectivity and coordination baseline. ## Sourcing Reality — EOL Part, Not a Dead End The lifecycle status is end-of-life hot (EOL). That means Schneider no longer manufactures the LC1F115V7. No factory lead time applies because there's no factory run. If you're replacing a failed unit on an existing panel, the plate-mount footprint (162 x 163.3 x 171 mm) and the power-circuit bolted connection are the dimensions you need to match. Mounting is plate-only — no DIN-rail clip on this frame size. The power circuit accepts bar (20 x 3 mm busbar cross-section), ring-terminal lugs up to 95 mm², or a bolted connection. Control wiring is screw-clamp terminals, 1 to 4 mm² flexible without ferrule, or 1 to 2.5 mm² with ferrule. Tightening torque is 10 N·m on the power circuit and 1.2 N·m on the control circuit. The IP2X front face with shrouds meets IEC 60529 — enough for a standard enclosed panel, not for washdown. Heat dissipation runs 5.9 to 7.2 W total, with 15 W per pole in AC-1 and 5 W per pole in AC-3. That's not a lot of heat for a 200 A frame, but in a densely packed panel you still want to check the thermal rise against the ambient operating range (-40 to 60 °C). The coil holds at 400 V AC 40-400 Hz, with a dropout window of 0.2 to 0.55 Uc — so it drops out somewhere between 80 and 220 V on that coil. That's a wide dropout band; don't count on it to sequence a downstream device without verifying the actual dropout point on your specific supply. ## Motor Power Coverage — What It Switches On a 400 V AC three-phase supply, the LC1F115V7 is rated for 55 kW in AC-3 (squirrel-cage motor starting). At 415 V it handles 59 kW, at 500 V it handles 75 kW, and at 690 V it handles 80 kW. For AC-4 (plugging / inching duty) at 400 V it's rated 18.5 kW — roughly one-third of the AC-3 figure, which is typical for the higher thermal stress of reversing and jogging. The utilisation categories are AC-3, AC-4, and AC-1 (resistive load), so it covers motor control and general switching.","metaTitle":"TeSys F LC1F115V7 Contactor, 3P, 200 A AC-3, 400 V Coil","metaDescription":"Schneider Electric TeSys F LC1F115V7 contactor, 3-pole, 200 A AC-3 rated operational current, 400 V AC coil. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"163.3 mm","Height":"162 mm","Standards":"IEC 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 EN 60947-1","Motor power kW":"55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 30 kW at 220...230 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"35 ms closing (at Uc) 130 ms opening (at Uc)","lifecycle_stage":"eol_hot","Heat dissipation":"5.9...7.2 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.37 mOhm - Ith 200 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Power circuit: 10 N.m Control circuit: 1.2 N.m","Compatibility code":"LC1F","Inrush power in VA":"770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"125 A aM at 200 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"920 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"15 W AC-1 5 W AC-3","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"200 A (at 115 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min","[Ith] conventional free air thermal current":"200 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/910ff1a4184eef86710f5ad82a047acb.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1F115V7/tesys-f-contactor-3p-3-no-ac3-440-v-115-a-coil-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F115V7/alternatives.json"},"ai":{"faq":[{"question":"What is the rated operational current of LC1F115V7?","answer":"The rated operational current (Ie) is 200 A in AC-3 duty at ≤440 V, per IEC 60947-4-1. That's the current it can switch motor loads up to, not just carry continuously."},{"question":"Where can I buy LC1F115V7 and how is it quoted?","answer":"This EOL part is sourced through independent distribution channels. It is quoted to order against an RFQ, with availability and current pricing confirmed at quote time. No factory lead time applies."},{"question":"What compliance standards does LC1F115V7 meet?","answer":"It conforms to IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. The rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 Group C. Overvoltage category is III."},{"question":"What is the mounting and connection type for LC1F115V7?","answer":"Plate mount only. Power circuit connections accept bar (20 x 3 mm busbar), ring-terminal lugs up to 95 mm², or bolted connection. Control circuit uses screw-clamp terminals for 1 to 4 mm² flexible or solid wire."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F115V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F115V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}