{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1400G7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1400G7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1400G7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1400G7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F1400G7, 3-pole contactor, 1400 A AC-1, 120 V AC 40-400 Hz coil, plate mount, end-of-life.","salesMarkdown":"The coil pulls 120 V AC at 40-400 Hz, with an inrush of 2200 VA and a hold-in draw of 36 VA. Opening time runs 100-170 ms; closing takes 40-75 ms. The 1400 A AC-1 rating governs resistive loads like heaters or large lighting banks. For motor duty (AC-3), this contactor would be derated significantly — the AC-1 figure is not the motor-switching number. Rated breaking capacity is 2100 A per IEC 60947-4-1. The control circuit is screw-clamp terminals accepting 1-4 mm² flexible or solid wire; the power circuit uses busbars up to 100 x 5 mm cross-section, torqued to 58 N·m. The LC1F1400G7 is certified to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It carries a TH protective treatment for tropical environments. Storage temperature range is -60 to 80 °C; operating ambient is -5 to 40 °C.","metaTitle":"Schneider LC1F1400G7 TeSys F Contactor, 1400 A AC-1, 120 VAC","metaDescription":"Schneider Electric LC1F1400G7 TeSys F 3-pole contactor. 1400 A rated operational current (AC-1), 120 VAC 40-400 Hz coil. End-of-life status; sourced to order. UL, CSA, IEC certifie","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","Height":"332 mm","Standards":"IEC 60947-1 EN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"100...170 ms opening 40...75 ms closing","lifecycle_stage":"eol_hot","Heat dissipation":"36 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 1700 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Inrush power in VA":"2200 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"1600 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 100 x 5 mm","Rated breaking capacity":"2100 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"150 W AC-1","[Uc] control circuit voltage":"120 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"1400 A (at <40 °C) AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"36 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"8000 A 40 °C - 10 s 6000 A 40 °C - 30 s 4500 A 40 °C - 1 min 4000 A 40 °C - 3 min 2600 A 40 °C - 10 min","[Ith] conventional free air thermal current":"1400 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8b7f66aa5f72a209cd97db032ae15bf4.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F1400G7/tesys-f-contactor-3p-3-no-ac1-1000-v-1400-a-coil-120-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1400G7/alternatives.json"},"ai":{"faq":[{"question":"What is the LC1F1400G7's depth?","answer":"The depth is 238.6 mm. Width is 438 mm, height is 332 mm. It is a plate-mount contactor."},{"question":"What compliance documentation does Schneider provide for the LC1F1400G7?","answer":"The contactor is certified to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It carries a TH protective treatment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1400G7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1400G7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}