{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1400V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1400V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1400V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1400V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F1400V7, 3-pole contactor, 1400 A AC-1, 400 VAC 40-400 Hz coil, plate mount, 438 x 332 x 238.6 mm.","salesMarkdown":"## TeSys F power contactor, 1400 A AC-1 — end-of-life sourcing note The Schneider Electric TeSys F LC1F1400V7 is a 3-pole contactor rated 1400 A in AC-1 utilisation category, meaning it's sized for resistive loads like large heating banks or industrial furnaces where inrush is minimal. The 400 VAC 40-400 Hz coil draws 2200 VA inrush and 36 VA hold-in. Rated operational voltage extends to 460 V DC, and the contactor carries IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1 approvals — accepted across European, North American, and Japanese (JIS C8201-4-1) jurisdictions. Plate-mounted for bolted busbar connections — power circuit accepts bar up to 100 x 5 mm. The 438 mm width and 332 mm height demand a generous panel footprint; not a DIN-rail part. Tightening torque on the power circuit is 58 N.m, control circuit 1.2 N.m. ## Lifecycle status: end-of-life — sourcing through independent channels The LC1F1400V7 is flagged end-of-life (EOL). The 1600 A gG fuse recommendation at ≤ 440 V and the 8 kA short-time withstand (10 s at 40 °C) remain valid for legacy replacements, but verify the specific duty cycle against the original installation. Heat dissipation runs 36 W total, with 150 W per pole in AC-1 duty. The 100-170 ms opening and 40-75 ms closing times are typical for a large frame contactor; coordinate with upstream short-circuit protection (1600 A gG fuse) for selective coordination. Operating altitude reaches 3000 m without derating. Ambient temperature range is -5 to 40 °C operating, -60 to 80 °C storage. Overvoltage category III and impulse withstand voltage of 8 kV suit fixed-installation power distribution.","metaTitle":"Schneider TeSys LC1F1400V7 Contactor, 1400 A AC-1, 400 VAC C","metaDescription":"Schneider Electric TeSys F LC1F1400V7 contactor, 1400 A AC-1 rated current, 400 VAC 50/60 Hz coil. IEC/UL/CSA certified. End-of-life — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","title":"LC1F1400V7","Height":"332 mm","Standards":"IEC 60947-4-1 EN 60947-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","description":"TeSys F contactor - 3P (3 NO) - AC-1 - <= 1000 V 1400 A - coil 400 V AC","Operating time":"100...170 ms opening 40...75 ms closing","lifecycle_stage":"eol_hot","Heat dissipation":"36 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 1700 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Inrush power in VA":"2200 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"1600 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 100 x 5 mm Power circuit: bolted connection","Rated breaking capacity":"2100 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"150 W AC-1","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"1400 A (at <40 °C) AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"36 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"8000 A 40 °C - 10 s 6000 A 40 °C - 30 s 4500 A 40 °C - 1 min 4000 A 40 °C - 3 min 2600 A 40 °C - 10 min","[Ith] conventional free air thermal current":"1400 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b0942df68ff31f28d2a65b82683ae996.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F1400V7/tesys-f-contactor-3p-3-no-ac1-1000-v-1400-a-coil-400-v-ac/"},"ai":{"faq":[{"question":"Where can I buy the LC1F1400V7 and get a price?","answer":"The LC1F1400V7 is sourced through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time against your order quantity."},{"question":"What compliance documentation does the LC1F1400V7 carry?","answer":"The LC1F1400V7 is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, JIS C8201-4-1, IEC 60947-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Protective treatment is TH (tropicalized)."},{"question":"What is the LC1F1400V7 rated for?","answer":"1400 A in AC-1 (resistive load) at ≤ 40 °C, with a 400 VAC 40-400 Hz coil. Rated operational voltage extends to 460 V DC. Conventional free-air thermal current (Ith) is also 1400 A at 40 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1400V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1400V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}