{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F150BD22L","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F150BD22L","canonicalUrl":"https://aoctrl.com/schneider/LC1F150BD22L","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F150BD22L","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor, LC1F150BD22L, 3-pole, 250 A AC-3, 24 V DC coil, 2 NO + 2 NC auxiliary contacts.","salesMarkdown":"The Schneider Electric LC1F150BD22L is a TeSys F series 3-pole contactor rated for 250 A in AC-3 duty (motor switching) at up to 440 V AC. That AC-3 rating governs its real-world motor load capability — it is sized for 75 kW at 380–400 V or 100 HP at 460 V (UL/CSA), so it handles large induction motors in pumps, compressors, and conveyors. The coil is 24 V DC, with an operational range of 0.85–1.1 Uc and a drop-out band of 0.15–0.2 Uc. Built-in auxiliary contacts are 2 NO + 2 NC. It carries IEC 60947-4-1 and EN 60947-4-1 certification for motor-starting duty, plus JIS C8201-4-1. The front face is IP2X with shrouds, acceptable for enclosed panel use where accidental finger contact is the concern. The LC1F150BD22L mounts on a plate (not DIN rail) — plan for bolted connection. Power circuit connections use bolted bars (2 x 25 x 3 mm) or ring terminals up to 120 mm²; control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid. Dimensions: 6.4 in (163.5 mm) wide, 6.7 in (171 mm) deep, 11.9 in (301 mm) tall. The 3-pole footprint is standard for the TeSys F frame. ## Key ratings and their meaning Rated breaking capacity is 1200 A per IEC 60947-4-1 — this is the current the contactor can safely interrupt under fault conditions, not the continuous rating. The associated fuse recommendation is 160 A aM or 250 A gG at ≤ 440 V, which sets the short-circuit coordination level. Mechanical durability is 10 million cycles; maximum operating rate is 2400 cycles per hour at 55 °C. Heat dissipation is 4.5 W holding (8 W per pole in AC-3), which matters for enclosure thermal calculations when multiple contactors are ganged. Protective treatment is TH (tropicalized) for humid environments.","metaTitle":"Schneider Electric LC1F150BD22L TeSys F Contactor, 250 A AC-","metaDescription":"Schneider Electric LC1F150BD22L TeSys F contactor, 250 A rated operational current (AC-3), 24 VDC coil, 2 NO + 2 NC aux contacts. EOL lifecycle; quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"6.7 in (171 mm)","Width":"6.4 in (163.5 mm)","Height":"11.9 in (301 mm)","Category":"US10NET39997","Standards":"IEC 60947-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1 JIS C8201-4-1","Motor power kW":"65 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 380...400 V AC 50/60 Hz (AC-3) 80 kW at 415 V AC 50/60 Hz (AC-3) 80 kW at 440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660...690 V AC 50/60 Hz (AC-3) 40 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"30...40 ms closing 30...50 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"4.5 W","Mounting Support":"Plate","Range of Product":"TeSys F","Average impedance":"0.35 mOhm - Ith 250 A 50 Hz","Device short name":"LC1F","Inrush power in W":"560 W 68 °F (20 °C))","Poles description":"3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 159.3 lbf.in (18 N.m)","Operating altitude":"9842.52 ft (3000 m) without derating","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed6 Gn, 5...300 Hz Shocks contactor open9 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms","Nbr. of units in pkg.":"1","Associated fuse rating":"160 A aM at 250 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bolted connection Power circuit 2 bars 25 x 3 mm Power circuit lugs-ring terminals 1 0.2 in² (120 mm²) Power circuit connector 1 0.2 in² (120 mm²)","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1200 A conforming to IEC 60947-4-1","Product or Component Type":"Contactor","motor power HP (UL / CSA)":"40 hp at 200 V AC 50 hp at 230 V AC 100 hp at 460 V AC 125 hp at 575 V AC","Power dissipation per pole":"22 W AC-1 8 W AC-3","[Uc] control circuit voltage":"24 V DC","Auxiliary contact composition":"2 NO + 2 NC","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C))","Hold-in power consumption in W":"4.5 W 68 °F (20 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"250 A (at 150 A (at <131 °F (55 °C)) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 460 V DC","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-40...140 °F (-40...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1200 A 104 °F (40 °C) - 10 s 700 A 104 °F (40 °C) - 30 s 600 A 104 °F (40 °C) - 1 min 450 A 104 °F (40 °C) - 3 min 350 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"250 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"140...158 °F (60...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ea79bd09110246a865e2655eb55e42a.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1F150BD22L/tesys-f-nonreversing-contactor-3p-open-600v-150a-24vdc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F150BD22L/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of LC1F150BD22L?","answer":"250 A rated operational current in AC-3 (motor duty), 24 V DC coil, 2 NO + 2 NC auxiliary contacts, rated breaking capacity 1200 A, mechanical durability 10 million cycles."},{"question":"What compliance documentation does this brand provide for LC1F150BD22L?","answer":"The contactor is certified to IEC 60947-1, EN 60947-1, IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. It carries IP2X front-face protection and overvoltage category III."},{"question":"What is the closest alternative to LC1F150BD22L in the TeSys F family?","answer":"Within the same TeSys F frame, a contactor with the same pole count and coil voltage but a higher AC-3 rating would physically fit the same mounting pattern and bus-bar spacing. However, no official successor order code is listed; verify electrical ratings against your load before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F150BD22L","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F150BD22L when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}