{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F150UD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F150UD","canonicalUrl":"https://aoctrl.com/schneider/LC1F150UD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F150UD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F150UD, 3-pole DC contactor, 250 A rated operational current (AC-3), 75 kW motor power at 400 V AC, 250 V DC coil.","salesMarkdown":"It carries a rated operational current (Ie) of 250 A at ≤440 V in AC-3 duty, which means it handles the inrush and running current of squirrel-cage motors up to that rating — not just the resistive heating curve. Motor power ratings span the common voltage bands: 75 kW at 380–400 V AC, 80 kW at 415 V and 440 V, 90 kW at 500 V, and 100 kW at 660–690 V AC, all in AC-3. For the higher-stress AC-4 duty (plugging, inching), it is rated 22 kW at 400 V. That spread tells you the part was sized for European and Asian voltage standards — 400 V is the sweet spot. Mechanical durability is 10 million cycles, so the wear life is in the bearings and springs, not the contacts, for typical motor-switching duty. Control circuit voltage is 250 V DC, with an operational range of 0.85 to 1.1 Uc at 55 °C and a drop-out range of 0.15 to 0.2 Uc. Heat dissipation is 4.5 W holding, with an inrush of 560 W at 20 °C. The rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Rated breaking capacity is 1200 A per IEC 60947-4-1. The front face with shrouds provides IP2X finger protection per IEC 60529 and VDE 0106, so it meets the basic touch-safety requirement for open panel mounting. Mounting is plate-style — not DIN-rail snap-on — so it bolts directly to a backplate or mounting rail in the enclosure. Dimensions are 6.7 in (171 mm) deep, 6.4 in (163.5 mm) wide, and 6.7 in (170 mm) tall, which is a standard TeSys F footprint. Power circuit connections are bar-type (2 x 25 x 3 mm), lugs, or bolted, accepting up to 120 mm² cable. Control circuit terminals are screw-clamp, accepting 1 to 4 mm² flexible or solid wire. Tightening torque for the power circuit is 159.3 lbf·in (18 N·m); the control circuit is 10.6 lbf·in (1.2 N·m). The average impedance per pole is 0.35 mOhm at 250 A.","metaTitle":"Schneider Electric LC1F150UD TeSys F Contactor, 250 A AC-3,","metaDescription":"Schneider Electric LC1F150UD TeSys F contactor. 250 A rated operational current (AC-3), 75 kW motor power at 400 V AC. End-of-life (EOL) status; sourced to order against RFQ. 3-pol","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"6.7 in (171 mm)","Range":"TeSys","Width":"6.4 in (163.5 mm)","Height":"6.7 in (170 mm)","Category":"22331-CTR,F-LINE,DC,OPEN,NONREV","Standards":"EN 60947-1 EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 JIS C8201-4-1","Motor power kW":"75 kW at 380...400 V AC 50/60 Hz (AC-3) 80 kW at 415 V AC 50/60 Hz (AC-3) 80 kW at 440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660...690 V AC 50/60 Hz (AC-3) 40 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"30...40 ms closing 30...50 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"4.5 W","Mounting Support":"Plate","Range of Product":"TeSys F","Average impedance":"0.35 mOhm - Ith 250 A 50 Hz","Device short name":"LC1F","Inrush power in W":"560 W 68 °F (20 °C))","Poles description":"3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 159.3 lbf.in (18 N.m)","Compatibility code":"LC1F","Operating altitude":"9842.52 ft (3000 m) without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"160 A aM at 250 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bar 2 25 x 3 mm Power circuit lugs-ring terminals 1 0.2 in² (120 mm²) Power circuit connector 1 0.2 in² (120 mm²) Power circuit bolted connection","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1200 A conforming to IEC 60947-4-1","Product or Component Type":"Contactor","Power dissipation per pole":"22 W AC-1 8 W AC-3","[Uc] control circuit voltage":"250 V DC","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 131 °F (55 °C))","Hold-in power consumption in W":"4.5 W 68 °F (20 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"250 A (at 150 A (at <131 °F (55 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-40...140 °F (-40...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1200 A 104 °F (40 °C) - 10 s 700 A 104 °F (40 °C) - 30 s 600 A 104 °F (40 °C) - 1 min 450 A 104 °F (40 °C) - 3 min 350 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"250 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"140...158 °F (60...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6bc5de3296c953bd7953677d919496aa.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1F150UD/tesys-f-contactor-3p-3-no-ac3-440-v-250-a-coil-250-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F150UD/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the LC1F150UD?","answer":"The LC1F150UD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — we do not maintain live stock counts for this EOL part on the website."},{"question":"What are the key specifications of the LC1F150UD?","answer":"The LC1F150UD is a 3-pole DC contactor rated 250 A AC-3 at ≤440 V, with motor power of 75 kW at 400 V. The coil is 250 V DC. It complies with IEC 60947-1, IEC 60947-4-1, and EN 60947-1. Mechanical durability is 10 million cycles."},{"question":"What compliance documentation does Schneider provide for the LC1F150UD?","answer":"The LC1F150UD is certified to IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. The protective treatment is TH (tropicalized). The front face with shrouds provides IP2X finger protection. RoHS and REACH compliance documentation is typically available from Schneider Electric's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F150UD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F150UD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}