{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F150V5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F150V5","canonicalUrl":"https://aoctrl.com/schneider/LC1F150V5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F150V5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F150V5, 3-pole contactor, 250 A rated operational current, 75 kW at 400 V AC (AC-3), 400 V AC 50 Hz coil, plate mount, EOL phase.","salesMarkdown":"It carries a rated operational current of 250 A in AC-3 duty at ≤ 440 V and switches motors up to 75 kW at 380–400 V AC, 80 kW at 415 V, and 100 kW at 660–690 V. The coil is 400 V AC 50 Hz, drawing 550 VA inrush and 45 VA hold-in. ## Lifecycle Status: End-of-Life (EOL) — What That Means for You The LC1F150V5 is in an end-of-life (EOL) phase. Schneider Electric no longer manufactures this order code. Sourcing is through independent distribution against an RFQ. The 250 A AC-3 rating is the motor-switching current — it governs the maximum full-load current of a squirrel-cage motor the contactor can break under starting conditions. That translates to 75 kW on a 400 V supply. The AC-1 rating (resistive load) is higher, but for motor control, AC-3 is the one that decides fit. The contactor also carries an AC-4 rating (22 kW at 400 V) for plugging or inching duty, where the load is switched under full stall current. The insulation voltage is 1000 V, and the overvoltage category is III, meaning it's designed for fixed-installation panels, not plug-in equipment. Mounts to a plate — not DIN rail, so plan for bolt-down installation with the 25 x 3 mm busbar or ring-terminal connections on the power circuit. The control circuit uses screw-clamp terminals accepting 1–4 mm² flexible or solid wire. Dimensions are 170 mm high, 163.5 mm wide, 171 mm deep. The front face carries IP2X protection with shrouds, meaning finger-safe from the front once shrouded, but the sides and bottom are open for ventilation. Heat dissipation runs 12–16 W total, with 8 W per pole in AC-3 and 22 W per pole in AC-1 — factor that into panel thermal calculations if it's in a sealed enclosure.","metaTitle":"Schneider TeSys F LC1F150V5 Contactor, 250 A, 75 kW AC-3, EO","metaDescription":"Schneider Electric TeSys F LC1F150V5 3-pole contactor, 250 A rated operational current, 75 kW at 400 V AC-3. EOL phase. Sourced to order against RFQ. IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"171 mm","Range":"TeSys","Width":"163.5 mm","Height":"170 mm","Standards":"EN 60947-1 IEC 60947-4-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-1","Motor power kW":"75 kW at 380...400 V AC 50/60 Hz (AC-3) 80 kW at 415 V AC 50/60 Hz (AC-3) 80 kW at 440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660...690 V AC 50/60 Hz (AC-3) 40 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"23...35 ms closing 5...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"12...16 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.35 mOhm - Ith 250 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 18 N.m","Compatibility code":"LC1F","Inrush power in VA":"550 VA, 50 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"160 A aM at 250 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 120 mm² Power circuit: connector 1 cable(s) 120 mm² Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1200 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"22 W AC-1 8 W AC-3","[Uc] control circuit voltage":"400 V AC 50 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"250 A (at 150 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"45 VA, 50 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-40...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1200 A 40 °C - 10 s 700 A 40 °C - 30 s 600 A 40 °C - 1 min 450 A 40 °C - 3 min 350 A 40 °C - 10 min","[Ith] conventional free air thermal current":"250 A (at 40 °C)","Permissible ambient air temperature around the device":"60...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e3741d8bef272f8aae09a27c6e7a3ecc.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1F150V5/tesys-f-contactor-3p-3-no-ac3-440-v-250-a-coil-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F150V5/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications of the LC1F150V5?","answer":"It is a 3-pole contactor rated 250 A in AC-3 (≤ 440 V), switching motors up to 75 kW at 400 V AC. The coil is 400 V AC 50 Hz. Mechanical durability is 10 million cycles. It complies with IEC 60947-4-1."},{"question":"Where can I buy the LC1F150V5 and get current pricing?","answer":"We source the LC1F150V5 to order against an RFQ through our independent distribution network. Send an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the closest alternative to the LC1F150V5?","answer":"The closest functional peer is another TeSys F contactor in the same 250 A AC-3 frame (LC1F150 series), but the coil voltage must match your control circuit. The LC1F150V5 uses a 400 V AC 50 Hz coil, so verify coil voltage before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F150V5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F150V5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}