{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F1700N7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F1700N7","canonicalUrl":"https://aoctrl.com/schneider/LC1F1700N7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F1700N7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F1700N7, 3-pole contactor, 1700 A AC-1 rated operational current, 415 VAC 40-400 Hz control circuit, plate-mount.","salesMarkdown":"## What the 1700 A AC-1 rating means for your BOM line The LC1F1700N7 is a 3-pole contactor from the TeSys F range, rated 1700 A conventional free-air thermal current (Ith) and 1700 A operational current in AC-1 utilisation category — that is, purely resistive loads like large heating banks, furnace elements, or power-factor correction capacitor banks. The AC-1 rating is the headline figure here; this contactor is not characterised for motor starting (AC-3) or mixed loads. The control circuit is 415 VAC at 40-400 Hz, with a pickup range of 0.85 to 1.1 Uc and a dropout band of 0.3 to 0.5 Uc — so on a 400 V nominal supply, the coil holds in above 340 V and drops out reliably below 208 V. ## Physical integration — plate-mount, bar connections, torque specs Mounting is plate-mount only — no DIN-rail option on this frame size. The dimensions are substantial: 438 mm wide, 332 mm high, 238.6 mm deep. Power-circuit connections are via bolted bars accepting up to three cables per pole with a busbar cross-section of 100 x 5 mm. Tightening torque on the power circuit is 58 N.m — that is a high-torque joint requiring a torque wrench, not a screwdriver. Control-circuit connections use screw-clamp terminals accepting 1 to 4 mm² flexible or solid wire, torqued to 1.2 N.m. The 36 W heat dissipation (200 W per pole in AC-1 duty) means the panel must account for thermal rise; forced ventilation or generous enclosure sizing is advisable at full rated current. ## Fault handling and coordination The LC1F1700N7 is rated for a short-time withstand current (Icw) of 10,000 A for 10 seconds at 40 °C, stepping down to 3,000 A for 10 minutes — this defines the maximum fault current the contactor can carry without welding its main poles while a backup overcurrent device clears. The associated fuse recommendation is 1600 A gG at ≤ 440 V. Rated breaking capacity is 2550 A per IEC 60947-4-1. Rated impulse withstand voltage is 8 kV, overvoltage category III, which suits fixed-installation distribution panels. The contactor is certified to IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Rated insulation voltage is 1000 V per IEC/UL 60947-4-1, and 1500 V per VDE 0110 group C. Protective treatment is TH (tropicalised) for humid environments. Storage temperature range is -60 to 80 °C; operating ambient is -5 to 40 °C.","metaTitle":"Schneider TeSys F LC1F1700N7 Contactor, 1700 A AC-1, 3P, 415","metaDescription":"Schneider Electric TeSys F LC1F1700N7 3-pole contactor, 1700 A AC-1 resistive rating, 415 VAC 50/60 Hz coil. End-of-life status — sourced to order against RFQ. IEC/UL/CSA listed.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"238.6 mm","Width":"438 mm","Height":"332 mm","Current":"1700 A (at <40 °C) AC AC-1","Voltage":"<= 460 V DC","Application":"Resistive load","Coil Voltage":"415 V AC 40...400 Hz","Operating Time":"100...170 ms opening 40...75 ms closing","Product Status":"End of Life","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Breaking Capacity":"2550 A conforming to IEC 60947-4-1","Insulation Voltage Ui":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1","Temp Operating Max":"40 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-60...80 °C","Control Circuit Type":"AC at 40...400 Hz","Utilization Category":"AC-1","Main Product Or Component Type":"Contactor","Ambient Air Temperature Operation":"-5...40 °C","Permissible Ambient Air Temperature Around The Device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4e8da8503b3f0bf4ca58f99d9ad67acd.pdf","sourceUrl":"https://www.se.com/nz/en/product/LC1F1700N7/tesys-f-contactor-3p-3-no-ac1-1000-v-1700-a-coil-415-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F1700N7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F1700N7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F1700N7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}