{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F185FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F185FE7","canonicalUrl":"https://aoctrl.com/schneider/LC1F185FE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F185FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F185FE7, 3-pole contactor, 115 V AC 40-400 Hz coil, 275 A AC-3 rated operational current, plate mount.","salesMarkdown":"The LC1F185FE7: The headline rating is 275 A at ≤ 440 V AC-3 — that is the motor-switching current, not the resistive load rating. AC-3 duty covers starting and running of squirrel-cage motors, so the 275 A figure governs the contactor's ability to handle inrush and break the motor circuit under load. For resistive loads (AC-1), the thermal current Ith is 275 A at 50 Hz with an average impedance of 0.33 mOhm per pole. The motor power table is the practical selection tool: 90 kW at 380-400 V, 100 kW at 415 V, 100 kW at 440 V, 110 kW at 500 V, and 110 kW at 660-690 V — all AC-3. At 220-230 V AC-3 it drops to 55 kW. For AC-4 reversing or inching duty at 400 V, the rating is 33 kW. The 115 V AC control coil (40-400 Hz) pulls 1070 VA inrush at cos φ 0.9; hold-in dissipation runs 8-9.8 W total. The coil pick-up range is 0.85-1.1 Uc, drop-out between 0.2-0.55 Uc — important for brownout ride-through assessment. The contactor is designed and tested to EN 60947-1, IEC 60947-1, EN 60947-4-1, IEC 60947-4-1, and JIS C8201-4-1. Rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C. Overvoltage category III. The rated breaking capacity is 1480 A per IEC 60947-4-1. Protective treatment is TH (tropicalized). Front face with shrouds achieves IP2X per IEC 60529 and VDE 0106. Associated fuse protection: 200 A aM or 315 A gG at ≤ 440 V. ## Mechanical & Mounting Mounting is plate-mount (not DIN rail). Dimensions: 174 mm height, 168.5 mm width, 181 mm depth. Power circuit connections accept bar (25 x 3 mm busbar), ring terminals, or bolted connection for 1 x 150 mm² cable. Control circuit uses screw clamp terminals accepting 1-4 mm² flexible or solid (1 or 2 cables). Tightening torque: 18 N.m on power circuit, 1.2 N.m on control. Mechanical durability is 10 million cycles; maximum operating rate is 2400 cycles per hour at 55 °C. Operating time: 35 ms closing, 130 ms opening at rated control voltage. ## Deployment Context The plate-mount form factor and 275 A AC-3 rating place it in the heavy-duty motor starter class — typically feeding conveyors, pumps, compressors, or large fans on 400-690 V three-phase supplies. The IP2X front face with shrouds provides basic finger protection inside an enclosed panel. The 115 V AC coil is standard for North American and some Asian control voltage schemes.","metaTitle":"Schneider Electric LC1F185FE7 TeSys F Contactor, 115 V AC Co","metaDescription":"Schneider Electric LC1F185FE7 TeSys F contactor. 115 V AC 40-400 Hz coil. 275 A AC-3 rated current. EOL hot — sourced to order against RFQ. IEC/EN/JIS compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"181 mm","Width":"168.5 mm","Height":"174 mm","Current":"275 A (at 185 A (at <55 °C) at <= 440 V AC-3","Voltage":"690 V AC 50/60 Hz","Application":"Resistive load, Motor control","Coil Voltage":"115 V AC 40...400 Hz","Operating Time":"35 ms closing at Uc) 130 ms opening at Uc)","Product Status":"End of Life","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Breaking Capacity":"1480 A conforming to IEC 60947-4-1","Motor Starter Type":"Direct on-line contactor","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-60...80 °C","Control Circuit Type":"AC at 40...400 Hz","Utilization Category":"AC-3 AC-4 AC-1","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor","Ambient Air Temperature Operation":"-5...55 °C","Permissible Ambient Air Temperature Around The Device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ca9922f0e67f66e4ac3667117efd9a0c.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1F185FE7/contactor-tesys-f-3p3no-ac3-440v-185a-115v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F185FE7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F185FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F185FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}