{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F185P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F185P7","canonicalUrl":"https://aoctrl.com/schneider/LC1F185P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F185P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F185P7 contactor, 3-pole, 275 A AC-3 rated operational current, 230 V AC 50/60 Hz coil, plate mount, 4.65 kg.","salesMarkdown":"## Motor power and duty-cycle coverage The LC1F185P7 is a 3-pole TeSys F contactor rated for 275 A at ≤440 V in AC-3 duty, with motor power ratings spanning 90 kW at 400 V up to 110 kW at 690 V. For AC-4 reversing or inching service, the motor power drops to 33 kW at 400 V — the higher switching frequency and arcing in AC-4 reduce the permissible load. The rated breaking capacity is 1480 A per IEC 60947-4-1, and the associated fuse recommendation is 200 A aM or 315 A gG at ≤440 V — this guides the upstream short-circuit protection coordination. ## Lifecycle status and sourcing posture This contactor is flagged as end-of-life hot (EOL hot) — the manufacturer has issued discontinuation notice. Sourcing is through independent distribution channels; availability and current pricing are confirmed at RFQ against the BOM quantity. ## Coil, control circuit, and mounting The coil is 230 V AC at 40–400 Hz, with an inrush power of 1070 VA at 20 °C. Control voltage limits are 0.85–1.1 Uc for pick-up and 0.2–0.55 Uc for drop-out at 55 °C. Closing time is 35 ms; opening time is 130 ms. Mounting is plate-mount only — no DIN-rail adapter. The power circuit accepts bar connections (25 x 3 mm busbar), ring terminals, or bolted connection up to 150 mm². Tightening torque is 18 N·m on the power circuit and 1.2 N·m on the control circuit. ## Standards compliance and environmental limits Certified to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Overvoltage category III. The front face achieves IP2X with shrouds per IEC 60529 and VDE 0106. Operating altitude is 3000 m without derating. Protective treatment is TH (tropicalised). Mechanical durability is 10 million cycles. Maximum operating rate is 2400 cycles/hour at 55 °C. Heat dissipation is 8–9.8 W overall, with 12 W per pole in AC-3 and 25 W per pole in AC-1.","metaTitle":"Schneider Electric LC1F185P7 TeSys F Contactor, 275 A AC-3","metaDescription":"Schneider Electric LC1F185P7 TeSys F contactor, 275 A rated operational current at ≤440 V AC-3, 90 kW motor power at 400 V.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"181 mm","Range":"TeSys","Width":"168.5 mm","Height":"174 mm","Standards":"EN 60947-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 JIS C8201-4-1","Motor power kW":"90 kW at 380...400 V AC 50/60 Hz (AC-3) 100 kW at 415 V AC 50/60 Hz (AC-3) 100 kW at 440 V AC 50/60 Hz (AC-3) 110 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 660...690 V AC 50/60 Hz (AC-3) 55 kW at 220...230 V AC 50/60 Hz (AC-3) 33 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"35 ms closing (at Uc) 130 ms opening (at Uc)","Product weight":"4.65 kg","lifecycle_stage":"eol_hot","Heat dissipation":"8...9.8 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.33 mOhm - Ith 275 A 50 Hz","Device short name":"LC1F","Motor Power Range":"30...50 kW at 200...240 V 3 phases 55...100 kW at 200...240 V 3 phases 55...100 kW at 380...440 V 3 phases 55...100 kW at 480...500 V 3 phases 110...220 kW at 480...500 V 3 phases","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 18 N.m","Compatibility code":"LC1F","Inrush power in VA":"1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Motor starter type":"Direct on-line contactor","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"200 A aM at 315 A gG at <= 440 V","Contactor coil voltage":"230 V AC standard","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 150 mm² Power circuit: connector 1 cable(s) 150 mm² Power circuit: bolted connection","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1480 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"12 W AC-3 25 W AC-1","[Uc] control circuit voltage":"230 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"275 A (at 185 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1500 A 40 °C - 10 s 920 A 40 °C - 30 s 740 A 40 °C - 1 min 500 A 40 °C - 3 min 400 A 40 °C - 10 min","[Ith] conventional free air thermal current":"275 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$647.70","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/LC1F185P7/tesys-f-contactor-3p-3-no-ac3-440-v-185-a-coil-230-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F185P7/alternatives.json"},"ai":{"faq":[{"question":"How can I get current pricing and availability for LC1F185P7?","answer":"Submit an RFQ against your BOM quantity. No stock-holding claim is made here."},{"question":"What compliance documentation does Schneider Electric provide for LC1F185P7?","answer":"The contactor is certified to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Overvoltage category III. The front face is IP2X with shrouds."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F185P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F185P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}