{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F185X622L","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F185X622L","canonicalUrl":"https://aoctrl.com/schneider/LC1F185X622L","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F185X622L","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F185X622L, 3-pole contactor, 275 A AC-3 rated operational current, 90 kW motor power at 400 V AC, 600 V AC control circuit voltage.","salesMarkdown":"## TeSys F 275 A Contactor — End-of-Life Sourcing Note The Schneider Electric LC1F185X622L is a 3-pole TeSys F contactor rated for 275 A in AC-3 duty (motor switching) at ≤ 440 V AC, making it the right fit for 90 kW motors on a 400 V line or 125 hp under UL/CSA at 460 V. The 275 A AC-3 figure governs real motor loads — the contactor's thermal current (Ith) is also 275 A, so there's no derating gap between the resistive and motor ratings at this frame size. It carries 2 NO + 2 NC auxiliary contacts built in, saving a separate aux block on many panels. AC-3 covers squirrel-cage motors: starting current around 6–8× FLA, switched off at full speed. The same contactor also carries AC-1 (resistive) loads at the same 275 A thermal current, and AC-4 (inching/plugging) at a derated 33 kW at 400 V. If your application involves frequent reversing or jogging, the AC-4 rating is the limiting factor — not the 275 A headline. Motor power ratings span the voltage range: 90 kW at 380–400 V, 100 kW at 415–440 V, 110 kW at 500–690 V, and 100 kW at 1000 V AC — all in AC-3. On UL/CSA duty, it delivers 125 hp at 460 V and 150 hp at 575 V. The control circuit is 600 V AC 60 Hz, with a pickup range of 0.85–1.1 Uc and dropout at 0.35–0.55 Uc at 55 °C. Mounts to a plate — not a DIN rail — so factor in the footprint: 7.1 in (181 mm) deep, 6.6 in (168.5 mm) wide, 12.008 in (305 mm) tall. Power connections are bolted, accepting two 25 x 3 mm bars or ring terminals up to 150 mm². Control circuit wiring uses screw clamp terminals accepting 1–4 mm² flexible or solid. Tightening torque: 159.3 lbf.in (18 N.m) on the power circuit, 10.6 lbf.in (1.2 N.m) on control wiring. Front face achieves IP2X with shrouds fitted (per IEC 60529 and VDE 0106), which is finger-safe but not splash-proof — keep it inside a closed panel. Protective treatment is TH (tropicalized/humid environment), so it handles high-condensation enclosures better than a standard untreated contactor. Certified to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Overvoltage category III, rated insulation voltage 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Associated fuse sizing: 200 A aM or 315 A gG at ≤ 440 V.","metaTitle":"Schneider Electric LC1F185X622L TeSys F Contactor, 275 A AC-","metaDescription":"Schneider Electric LC1F185X622L TeSys F contactor, 3-pole, 275 A AC-3 rated operational current, 90 kW at 400 V AC. EOL lifecycle. Sourced to order against RFQ. IEC 60947-4-1, UL/C","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"7.1 in (181 mm)","Width":"6.6 in (168.5 mm)","Height":"12.008 in (305 mm)","Category":"39997-CANADIAN PRODUCTS","Standards":"IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 IEC 60947-1 EN 60947-4-1","Motor power kW":"90 kW at 380...400 V AC 50/60 Hz (AC-3) 100 kW at 415 V AC 50/60 Hz (AC-3) 100 kW at 440 V AC 50/60 Hz (AC-3) 110 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 660...690 V AC 50/60 Hz (AC-3) 100 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 220...230 V AC 50/60 Hz (AC-3) 33 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"20...35 ms closing 7...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"18...24 W","Mounting Support":"Plate","Range of Product":"TeSys F","Average impedance":"0.33 mOhm - Ith 275 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 159.3 lbf.in (18 N.m)","Inrush power in VA":"970 VA, 60 Hz 0.3 68 °F (20 °C))","Operating altitude":"9842.52 ft (3000 m) without derating","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open7 Gn for 11 ms","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A aM at 315 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bolted connection Power circuit 2 bars 25 x 3 mm Power circuit lugs-ring terminals 1 0.2 in² (150 mm²) Power circuit connector 1 0.2 in² (150 mm²)","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1480 A conforming to IEC 60947-4-1","Product or Component Type":"Contactor","motor power HP (UL / CSA)":"50 hp at 200 V AC 60 hp at 230 V AC 125 hp at 460 V AC 150 hp at 575 V AC","Power dissipation per pole":"12 W AC-3 25 W AC-1","[Uc] control circuit voltage":"600 V AC 60 Hz","Auxiliary contact composition":"2 NO + 2 NC","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C))","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"275 A (at 185 A (at <131 °F (55 °C)) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"66 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1500 A 104 °F (40 °C) - 10 s 920 A 104 °F (40 °C) - 30 s 740 A 104 °F (40 °C) - 1 min 500 A 104 °F (40 °C) - 3 min 400 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"275 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1dd8b35d0dbff29b4613ac6640115c5e.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1F185X622L/tesys-f-nonreversing-contactor-3p-open-600v-185a-600vac-40400hz-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F185X622L/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for LC1F185X622L?","answer":"The LC1F185X622L is a 3-pole TeSys F contactor rated 275 A AC-3 at ≤ 440 V, 90 kW motor power at 400 V AC, with a 600 V AC control circuit. It carries 2 NO + 2 NC auxiliary contacts and meets IEC 60947-4-1 and UL/CSA standards."},{"question":"Where can I buy LC1F185X622L?","answer":"The LC1F185X622L is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm commitment."},{"question":"What compliance documentation does Schneider provide for LC1F185X622L?","answer":"The contactor is certified to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, JIS C8201-4-1, and carries UL/CSA horsepower ratings (125 hp at 460 V, 150 hp at 575 V). Overvoltage category III and rated insulation voltage 1000 V (IEC) / 1500 V (VDE)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F185X622L","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F185X622L when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}