{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2100FD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2100FD","canonicalUrl":"https://aoctrl.com/schneider/LC1F2100FD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2100FD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2100FD, 3-pole contactor, 2100 A AC-1, 110 V DC coil, plate mount, 438 x 332 x 238.6 mm.","salesMarkdown":"The Schneider Electric TeSys F LC1F2100FD is a 3-pole contactor rated for 2100 A in AC-1 duty (resistive loads), with a 110 V DC coil. It is designed for heavy switching of resistive heating elements, large lighting banks, or similar non-inductive loads in industrial power distribution panels. This part is end-of-life (EOL) per the manufacturer. No direct replacement is listed in the evidence. The 110 V DC coil operates from 0.85 to 1.1 Uc at 55 °C and drops out between 0.2 and 0.35 Uc. Hold-in power is 10 W at 20 °C; inrush is 2100 W. Rated short-time withstand current (Icw) is 10 kA for 10 s, 7.5 kA for 30 s, and 3 kA for 10 min at 40 °C — this defines the upstream protection coordination window. The associated fuse recommendation is 2000 A gG at ≤ 440 V. Rated breaking capacity is 3150 A per IEC 60947-4-1. Operating time is 50–60 ms closing, 45–60 ms opening. Maximum operating rate is 600 cycles/hour at 55 °C. Mounting is plate-only (no DIN-rail option). Dimensions: 438 mm wide, 332 mm high, 238.6 mm deep. Power circuit connections use bolted bars (busbar cross-section 100 x 5 mm, 4 cables). Control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid. Compliance covers IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V (IEC/UL) and 1500 V per VDE 0110 group C. Impulse withstand is 8 kV, overvoltage category III.","metaTitle":"TeSys F LC1F2100FD Contactor, 2100 A AC-1, 110 V DC Coil","metaDescription":"Schneider Electric TeSys F LC1F2100FD 3-pole contactor, 2100 A AC-1, 110 V DC coil. End-of-life status; sourced to order. IEC/UL/CSA certified. Request RFQ for pricing and availabi","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"238.6 mm","Width":"438 mm","Height":"332 mm","Current":"2100 A (at <40 °C) AC AC-1","Voltage":"<= 460 V DC","Application":"Resistive load","Coil Voltage":"110 V DC","Operating Time":"50...60 ms closing 45...60 ms opening","Product Status":"End of Life","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Breaking Capacity":"3150 A conforming to IEC 60947-4-1","Temp Operating Max":"40 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-60...80 °C","Control Circuit Type":"DC standard","Utilization Category":"AC-1","Main Product Or Component Type":"Contactor","Ambient Air Temperature Operation":"-5...40 °C","Permissible Ambient Air Temperature Around The Device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7410d8a550a2f8c32a977f730da2c0b2.pdf","sourceUrl":"https://www.se.com/th/en/product/LC1F2100FD/tesys-f-contactor-3p-3-no-ac1-1000-v-2100-a-coil-110-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2100FD/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2100FD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2100FD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}