{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2100FD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2100FD","canonicalUrl":"https://aoctrl.com/schneider/LC1F2100FD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2100FD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2100FD, 3-pole contactor, 2100 A AC-1, 110 V DC coil, plate mount, 438 x 332 x 238.6 mm.","salesMarkdown":"The Schneider Electric TeSys F LC1F2100FD is a 3-pole contactor rated for 2100 A in AC-1 duty (resistive loads), with a 110 V DC coil. It is designed for heavy switching of resistive heating elements, large lighting banks, or similar non-inductive loads in industrial power distribution panels. This part is end-of-life (EOL) per the manufacturer. No direct replacement is listed in the evidence. The 110 V DC coil operates from 0.85 to 1.1 Uc at 55 °C and drops out between 0.2 and 0.35 Uc. Hold-in power is 10 W at 20 °C; inrush is 2100 W. Rated short-time withstand current (Icw) is 10 kA for 10 s, 7.5 kA for 30 s, and 3 kA for 10 min at 40 °C — this defines the upstream protection coordination window. The associated fuse recommendation is 2000 A gG at ≤ 440 V. Rated breaking capacity is 3150 A per IEC 60947-4-1. Operating time is 50–60 ms closing, 45–60 ms opening. Maximum operating rate is 600 cycles/hour at 55 °C. Mounting is plate-only (no DIN-rail option). Dimensions: 438 mm wide, 332 mm high, 238.6 mm deep. Power circuit connections use bolted bars (busbar cross-section 100 x 5 mm, 4 cables). Control circuit uses screw clamp terminals accepting 1–4 mm² flexible or solid. Compliance covers IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V (IEC/UL) and 1500 V per VDE 0110 group C. Impulse withstand is 8 kV, overvoltage category III.","metaTitle":"TeSys F LC1F2100FD Contactor, 2100 A AC-1, 110 V DC Coil","metaDescription":"Schneider Electric TeSys F LC1F2100FD 3-pole contactor, 2100 A AC-1, 110 V DC coil. End-of-life status; sourced to order. IEC/UL/CSA certified. Request RFQ for pricing and availabi","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","title":"LC1F2100FD","Height":"332 mm","Standards":"IEC 60947-1 IEC 60947-4-1 EN 60947-4-1 EN 60947-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","description":"TeSys F contactor - 3P (3 NO) - AC-1 - <= 1000 V 2100 A - coil 110 V DC","Operating time":"50...60 ms closing 45...60 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"10 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2100 A 50 Hz","Device short name":"LC1F","Inrush power in W":"2100 W (at 20 °C)","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Operating altitude":"3000 m without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2000 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 4 cable(s) - busbar cross section: 100 x 5 mm Power circuit: bolted connection","Rated breaking capacity":"3150 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"200 W AC-1","[Uc] control circuit voltage":"110 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.2...0.35 Uc (at 55 °C)","Hold-in power consumption in W":"10 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2100 A (at <40 °C) AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"10000 A 40 °C - 10 s 7500 A 40 °C - 30 s 5500 A 40 °C - 1 min 4200 A 40 °C - 3 min 3000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2100 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7410d8a550a2f8c32a977f730da2c0b2.pdf","sourceUrl":"https://www.se.com/th/en/product/LC1F2100FD/tesys-f-contactor-3p-3-no-ac1-1000-v-2100-a-coil-110-v-dc/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2100FD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2100FD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}