{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2100M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2100M7","canonicalUrl":"https://aoctrl.com/schneider/LC1F2100M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2100M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2100M7, 3-pole contactor, 2100 A AC-1 rated operational current, 220 VAC 40-400 Hz control circuit, plate mount.","salesMarkdown":"The Schneider Electric TeSys F LC1F2100M7 is a 3-pole contactor rated for 2100 A in AC-1 duty (resistive loads) at up to 40 °C ambient. That AC-1 rating — 2100 A conventional free-air thermal current — means it's sized for heavy resistive switching, like large heating banks or furnace loads, not motor starting. The control circuit runs on 220 VAC 40-400 Hz, with a pickup range of 0.85 to 1.1 times nominal and dropout at 0.3 to 0.5 times nominal at 55 °C. The 2100 A AC-1 rating is the headline number, but pay attention to the breaking capacity: 3150 A per IEC 60947-4-1. That's the current it can safely interrupt under fault conditions. The short-time withstand current (Icw) is 10 kA for 10 seconds at 40 °C — useful for coordination studies if you're sizing upstream protection. Associated fuse recommendation is 2000 A gG at up to 440 V. Plate-mounted, dimensions 438 mm wide x 332 mm high x 238.6 mm deep — plan your enclosure layout accordingly. Heat dissipation is 36 W total, 200 W per pole in AC-1 duty, so ventilation matters in a sealed panel. The LC1F2100M7 carries compliance with IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C, and 1000 V per UL 60947-4-1. Impulse withstand voltage is 8 kV, overvoltage category III. Protective treatment is TH (tropicalized).","metaTitle":"Schneider TeSys F LC1F2100M7 Contactor, 2100 A AC-1, 220 VAC","metaDescription":"Schneider Electric TeSys F LC1F2100M7 3-pole contactor, 2100 A AC-1 rated current, 220 VAC 40-400 Hz coil. End-of-life status; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","Height":"332 mm","Standards":"IEC 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"100...170 ms opening 40...75 ms closing","lifecycle_stage":"eol_hot","Heat dissipation":"36 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2100 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Inrush power in VA":"2200 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2000 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 4 cable(s) - busbar cross section: 100 x 5 mm Power circuit: bolted connection","Rated breaking capacity":"3150 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"200 W AC-1","[Uc] control circuit voltage":"220 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2100 A (at <40 °C) AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"36 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"10000 A 40 °C - 10 s 7500 A 40 °C - 30 s 5500 A 40 °C - 1 min 4200 A 40 °C - 3 min 3000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2100 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d7209da5a0e0adcf8a6a4157f9c1d5b1.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1F2100M7/contactor-tesys-f-3p3no-ac1-1000v-2100a-coil-220v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2100M7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of LC1F2100M7?","answer":"Rated operational current is 2100 A in AC-1 (resistive loads) at up to 40 °C. Control circuit voltage is 220 VAC 40-400 Hz. Breaking capacity is 3150 A per IEC 60947-4-1. Short-time withstand current is 10 kA for 10 seconds at 40 °C."},{"question":"What compliance documentation does LC1F2100M7 carry?","answer":"The contactor complies with IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2100M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2100M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}