{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2100V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2100V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F2100V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2100V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F2100V7, 3-pole contactor, 2100 A AC-1, 400 V AC 40-400 Hz coil, plate mount, 438 x 332 x 238.6 mm.","salesMarkdown":"## TeSys F 2100 A AC-1 Contactor — Compliance and Application The Schneider Electric LC1F2100V7 is a 3-pole contactor from the TeSys F series, rated for 2100 A conventional free-air thermal current (Ith) at 40 °C, with an AC-1 utilisation category for resistive loads. The 2100 A AC-1 rating means it handles high continuous resistive current — typical for large furnace banks, electric heating elements, or industrial ovens — without derating for motor inrush. Control circuit is 400 V AC at 40-400 Hz, with a hold-in consumption of 36 VA and inrush of 2200 VA. The part carries full certification to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1, plus JIS C8201-4-1 — meeting the compliance documentation requirements for global panel builds and supplier-quality sign-off. ## Plate Mounting and Panel Integration Mounting support is plate — not DIN rail — so the contactor bolts directly to a backplate or mounting panel. Dimensions are 438 mm wide by 332 mm high by 238.6 mm deep. Power circuit connections use bars with a busbar cross-section of 100 x 5 mm, bolted connection; control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid. Tightening torque is 58 N·m on the power circuit and 1.2 N·m on the control circuit. The 36 W heat dissipation (200 W per pole in AC-1) must be factored into enclosure thermal calculations — at 2100 A, forced ventilation or a larger cabinet volume is expected. ## AC-1 Duty and Short-Circuit Coordination Rated breaking capacity is 3150 A conforming to IEC 60947-4-1. The associated fuse rating is 2000 A gG at ≤ 440 V. Short-time withstand current (Icw) is 10,000 A for 10 seconds, 7500 A for 30 s, 5500 A for 1 min, 4200 A for 3 min, and 3000 A for 10 min — all at 40 °C. The 0.1 mOhm average impedance at 2100 A 50 Hz translates to roughly 210 mV drop per pole at full load, which is consistent with the 200 W/pole dissipation figure. Operating time is 100-170 ms opening, 40-75 ms closing. Maximum operating rate is 600 cycles per hour at 55 °C. ## Environmental and Altitude Ratings Operating ambient temperature range is -5 to 40 °C; storage range is -60 to 80 °C. Protective treatment is TH (tropicalisation — humidity and corrosion resistant). Overvoltage category is III, with a rated impulse withstand voltage of 8 kV. Rated insulation voltage is 1000 V per IEC 60947-4-1 and UL 60947-4-1, and 1500 V per VDE 0110 group C.","metaTitle":"Schneider Electric LC1F2100V7 TeSys F Contactor, 2100 A AC-1","metaDescription":"Schneider Electric LC1F2100V7 TeSys F contactor, 2100 A AC-1 rated operational current, 3 poles, 400 V AC 40-400 Hz control circuit. Certified to IEC 60947-4-1, UL 60947-4-1, CSA C","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"238.6 mm","Range":"TeSys","Width":"438 mm","Height":"332 mm","Standards":"JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"100...170 ms opening 40...75 ms closing","lifecycle_stage":"eol_hot","Heat dissipation":"36 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2100 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Inrush power in VA":"2200 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2000 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 4 cable(s) - busbar cross section: 100 x 5 mm Power circuit: bolted connection","Rated breaking capacity":"3150 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"200 W AC-1","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2100 A (at <40 °C) AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"36 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"10000 A 40 °C - 10 s 7500 A 40 °C - 30 s 5500 A 40 °C - 1 min 4200 A 40 °C - 3 min 3000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2100 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/895281dcd6862101b76fa115c939e2d8.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1F2100V7/contactor-tesys-f-3p3no-ac1-1000v-2100a-coil-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2100V7/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for LC1F2100V7?","answer":"The LC1F2100V7 is certified to IEC 60947-4-1, EN 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC/UL and 1500 V per VDE 0110 group C. A full declaration of conformity covering these standards is available from the manufacturer."},{"question":"What is the closest alternative to LC1F2100V7 in the TeSys F family?","answer":"Within the TeSys F range, the closest parametric match would be another 3-pole contactor with a 2100 A AC-1 rating and a 400 V AC coil, but no official successor order code is listed in the lifecycle record. A parametric search against the 2100 A AC-1 / 400 V AC coil / 3-pole / plate-mount profile is the practical path for a cross-reference."},{"question":"Where can I buy LC1F2100V7 and how is it quoted?","answer":"The LC1F2100V7 is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2100V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2100V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}