{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F225P5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F225P5","canonicalUrl":"https://aoctrl.com/schneider/LC1F225P5","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F225P5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, LC1F225P5, 3-pole contactor, 315 A AC-3, 110 kW at 400 V, 230 V AC 50 Hz coil, plate mount.","salesMarkdown":"The Schneider Electric LC1F225P5 is a 3-pole TeSys F contactor rated for 315 A operational current in AC-3 duty, switching motor loads up to 110 kW at 380–400 V AC. Rated breaking capacity is 1800 A per IEC 60947-4-1, and the contactor is listed for utilisation categories AC-1 (resistive), AC-3 (squirrel-cage motor start/run), and AC-4 (plugging/inching). That means it handles both steady resistive loads and the inductive inrush of motor starting, but AC-4 duty — frequent reversing or jogging — will wear the contacts faster; the mechanical durability of 10 Mcycles gives a sense of the base life before contact maintenance. The 315 A AC-3 rating is the headline number, but the real fit check is the motor power at your line voltage: 110 kW at 400 V, 129 kW at 500 V, and 63 kW at 230 V. If your motor is 110 kW at 400 V, this contactor lands right on the rating — no headroom for derating if ambient hits 55 °C (the max operating temp). The coil hold-in draw is 55 VA at 50 Hz; the inrush is 805 VA, so the control transformer needs to handle that surge without dropping below 0.85 Uc (196 V for a 230 V coil). Power connections accept bar or lug terminals up to 185 mm² cable; control wiring is screw-clamp, 1–4 mm² flexible or solid. Tightening torque is 35 N·m on the power side and 1.2 N·m on the control side — a torque wrench is non-negotiable for the power lugs to avoid hot spots at 315 A. ## Deployment context Plate-mounted in a motor control centre or panel, this contactor is sized for a 3-pole motor branch circuit. The 181 mm depth and 168.5 mm width mean it fits a standard backplate with generous side clearance for arc flash and cable bending radius.","metaTitle":"Schneider Electric LC1F225P5 TeSys F Contactor, 315 A AC-3,","metaDescription":"Schneider Electric LC1F225P5 TeSys F contactor. 315 A rated operational current (AC-3), 110 kW motor power at 400 V. End-of-life status; sourced to order against RFQ. IEC 60947-4-1","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"181 mm","Range":"TeSys","Width":"168.5 mm","Height":"197 mm","Standards":"IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1 IEC 60947-1","Motor power kW":"110 kW at 380...400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660...690 V AC 50/60 Hz (AC-3) 63 kW at 220...230 V AC 50/60 Hz (AC-3) 40 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"20...35 ms closing 7...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"18...24 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.32 mOhm - Ith 315 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Inrush power in VA":"805 VA, 50 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 50 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"315 A gG at 250 A aM at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 185 mm² Power circuit: connector 1 cable(s) 185 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1800 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"32 W AC-1 16 W AC-3","[Uc] control circuit voltage":"230 V AC 50 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"315 A (at 225 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"55 VA, 50 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1800 A 40 °C - 10 s 1000 A 40 °C - 30 s 850 A 40 °C - 1 min 560 A 40 °C - 3 min 440 A 40 °C - 10 min","[Ith] conventional free air thermal current":"315 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d7546b755680bc82fa712d40038d60d3.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F225P5/tesys-f-contactor-3p-3-no-ac3-440-v-225-a-coil-230-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F225P5/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LC1F225P5 and how do I get a price?","answer":"We source LC1F225P5 to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to LC1F225P5?","answer":"No official successor order code is listed for this part. Any alternative would need to be validated against the original panel design for footprint, coil voltage, and current rating."},{"question":"What is LC1F225P5's listed depth?","answer":"The depth is 181 mm."},{"question":"What compliance documentation does this brand provide for LC1F225P5?","answer":"The contactor is certified to IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Protective treatment is TH (tropicalised)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F225P5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F225P5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}