{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F225Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F225Q6","canonicalUrl":"https://aoctrl.com/schneider/LC1F225Q6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F225Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F225Q6, 3-pole contactor, 315 A AC-3 rated operational current, 110 kW motor power at 400 V, 380 V AC 60 Hz control coil, end-of-life.","salesMarkdown":"The Schneider Electric LC1F225Q6 is a TeSys F series 3-pole contactor rated for 315 A operational current in AC-3 duty (motor switching) at ≤ 440 V, with a 380 V AC 60 Hz control coil. It switches motor loads up to 110 kW at 380–400 V AC and 129 kW at 500 V, covering the common European and Asian line voltages. The 315 A AC-3 rating means it handles the inrush and breaking of squirrel-cage induction motors at that current — not just resistive loads — so it is sized for a 110 kW motor at 400 V, not a general-purpose 315 A switch. ## Standards and approvals — what the ratings certify The LC1F225Q6 is designed and tested to IEC 60947-4-1 and IEC 60947-1, the core standards for contactors and motor-starters. It also carries JIS C8201-4-1 and EN 60947-1/4-1 compliance, making it accepted in European, Japanese, and many other markets without re-certification. The rated insulation voltage is 1000 V per IEC 60947-4-1, overvoltage category III, so it is suitable for fixed-installation industrial panels with transient overvoltages up to that category. The IP20 front face with shrouds (per IEC 60529 and VDE 0106) means finger-safe when installed in an enclosure — no additional guarding needed on the front. ## Mounting and integration — plate-mount, not DIN rail Mounting is plate-only — no DIN-rail clip, so plan for a backplate or sub-panel with drilled/tapped holes. Dimensions are 197 mm high, 168.5 mm wide, 181 mm deep. Power connections are bolted bar or ring-terminal lugs accepting up to 185 mm² cable; control wiring is screw-clamp terminals accepting 1–4 mm² flexible or solid. Tightening torque is 35 N·m on the power circuit and 1.2 N·m on the control circuit — a torque wrench is needed for the power connections. Heat dissipation is 18–24 W total, with 32 W per pole in AC-1 (resistive) and 16 W per pole in AC-3 (motor) duty. That is moderate for a contactor this size — expect some thermal rise in a sealed cabinet, but not enough to force a fan in most installations. The associated fuse recommendation is 315 A gG or 250 A aM at ≤ 440 V — coordinate your upstream protection accordingly.","metaTitle":"Schneider LC1F225Q6 TeSys F Contactor, 315 A AC-3, 110 kW, E","metaDescription":"Schneider Electric LC1F225Q6 TeSys F contactor, 3-pole, 315 A AC-3 rated operational current, 110 kW motor power at 400 V. End-of-life status; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"181 mm","Range":"TeSys","Width":"168.5 mm","Height":"197 mm","Standards":"IEC 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1","Motor power kW":"110 kW at 380...400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660...690 V AC 50/60 Hz (AC-3) 63 kW at 220...230 V AC 50/60 Hz (AC-3) 40 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"20...35 ms closing 7...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"18...24 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.32 mOhm - Ith 315 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Inrush power in VA":"970 VA, 60 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 60 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"315 A gG at 250 A aM at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 185 mm² Power circuit: connector 1 cable(s) 185 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1800 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"32 W AC-1 16 W AC-3","[Uc] control circuit voltage":"380 V AC 60 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"315 A (at 225 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"66 VA, 60 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1800 A 40 °C - 10 s 1000 A 40 °C - 30 s 850 A 40 °C - 1 min 560 A 40 °C - 3 min 440 A 40 °C - 10 min","[Ith] conventional free air thermal current":"315 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d3aa2005cf5a0b9d36668c63b14119ac.pdf","sourceUrl":"https://www.se.com/th/en/product/LC1F225Q6/tesys-f-contactor-3p-3-no-ac3-440-v-225-a-coil-380-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F225Q6/alternatives.json"},"ai":{"faq":[{"question":"What motor power does the LC1F225Q6 handle at 400 V?","answer":"It handles 110 kW at 380–400 V AC in AC-3 duty. At 415 V it is also 110 kW, and at 440 V the same. At 500 V it handles 129 kW, and at 660–690 V also 129 kW. At 220–230 V it is rated 63 kW."},{"question":"What standards does the LC1F225Q6 comply with?","answer":"It complies with IEC 60947-4-1, IEC 60947-1, JIS C8201-4-1, EN 60947-1, and EN 60947-4-1. The rated insulation voltage is 1000 V per IEC 60947-4-1, overvoltage category III."},{"question":"Where can I buy the LC1F225Q6?","answer":"The LC1F225Q6 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm commitment on quantity and delivery."},{"question":"What is the depth of the LC1F225Q6?","answer":"The depth is 181 mm. Overall dimensions are 197 mm high, 168.5 mm wide, and 181 mm deep. Mounting is plate-only, not DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F225Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F225Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}