{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F225R6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F225R6","canonicalUrl":"https://aoctrl.com/schneider/LC1F225R6","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F225R6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, LC1F225R6, 3-pole contactor, 315 A AC-3, 110 kW at 400 V, plate mount, IEC 60947-4-1.","salesMarkdown":"Its headline rating is 315 A in AC-3 duty at ≤440 V, which means it switches three-phase induction motors up to 110 kW at 400 V AC — the figure that decides fit for a pump, fan, or compressor BOM line. The same contactor also carries AC-1 (resistive) and AC-4 (plugging/inching) utilisation categories, so it covers both distribution and heavy-duty reversing applications. The control circuit is 440 V AC 60 Hz, with a hold-in consumption of 66 VA at 60 Hz. Closing time runs 20–35 ms, opening 7–15 ms — fast enough for most motor-starting sequences but not a high-speed DC switching contactor. This contactor mounts to a plate, not a DIN rail — factor that into your panel layout. Dimensions are 197 mm high, 168.5 mm wide, 181 mm deep. Power connections are bolted bar or ring-terminal lugs accepting up to 185 mm² cable; control wiring uses screw-clamp terminals accepting 1–4 mm² flexible or solid. Tightening torque is 35 N·m on the power circuit, 1.2 N·m on the control circuit. IP20 on the front face with shrouds fitted. Heat dissipation runs 18–24 W total, with per-pole dissipation of 32 W in AC-1 and 16 W in AC-3. Ambient operating range is –5 to 55 °C, storage –60 to 80 °C. The contactor complies with IEC 60947-4-1 and EN 60947-4-1, plus JIS C8201-4-1. Rated breaking capacity is 1800 A per IEC 60947-4-1. Associated fuse ratings are 315 A gG or 250 A aM at ≤440 V. Overvoltage category III, protective treatment TH (tropicalised). Mechanical durability is 10 million cycles.","metaTitle":"Schneider Electric LC1F225R6 TeSys F Contactor, 315 A AC-3,","metaDescription":"Schneider Electric LC1F225R6 TeSys F contactor, 315 A rated operational current (AC-3), 110 kW motor power at 400 V. End-of-life hot status; sourced to order against RFQ. IEC 60947","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"181 mm","Range":"TeSys","Width":"168.5 mm","Height":"197 mm","Standards":"IEC 60947-1 EN 60947-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-4-1","Motor power kW":"110 kW at 380...400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660...690 V AC 50/60 Hz (AC-3) 63 kW at 220...230 V AC 50/60 Hz (AC-3) 40 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"20...35 ms closing 7...15 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"18...24 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.32 mOhm - Ith 315 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Inrush power in VA":"970 VA, 60 Hz cos phi 0.3 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 60 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"315 A gG at 250 A aM at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 185 mm² Power circuit: connector 1 cable(s) 185 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1800 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"32 W AC-1 16 W AC-3","[Uc] control circuit voltage":"440 V AC 60 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"315 A (at 225 A (at <55 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 690 V AC 50/60 Hz","Hold-in power consumption in VA":"66 VA, 60 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1800 A 40 °C - 10 s 1000 A 40 °C - 30 s 850 A 40 °C - 1 min 560 A 40 °C - 3 min 440 A 40 °C - 10 min","[Ith] conventional free air thermal current":"315 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bdc32563130a39e53616ce27c0bd91b1.pdf","sourceUrl":"https://www.se.com/nz/en/product/LC1F225R6/tesys-f-contactor-3p-3-no-ac3-440-v-225-a-coil-440-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F225R6/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LC1F225R6?","answer":"Submit an RFQ through this listing. Pricing and availability are confirmed at quote time through independent distribution channels — no manufacturer stock or lead-time applies since the part is end-of-life."},{"question":"What is the closest alternative to LC1F225R6 in the TeSys F family?","answer":"No official successor order code is listed in the available lifecycle data. A parametric match within the TeSys F range would need the same 315 A AC-3 rating, 110 kW at 400 V, and plate-mount footprint — but without a published cross-reference, verify fit against your specific BOM before substituting."},{"question":"What compliance documentation does Schneider provide for LC1F225R6?","answer":"The contactor is certified to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. It carries IP20 front-face protection with shrouds. RoHS and REACH compliance documentation is typically available from Schneider's documentation portal for the TeSys F series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F225R6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F225R6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}