{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2600FD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2600FD","canonicalUrl":"https://aoctrl.com/schneider/LC1F2600FD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2600FD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F2600FD, 3-pole contactor, 2600 A rated operational current AC-1, 110 V DC control circuit, plate mount.","salesMarkdown":"The Schneider Electric TeSys F LC1F2600FD is a 3-pole contactor rated 2600 A in AC-1 utilisation category — that's resistive load switching (heaters, lighting banks, large transformer primaries), not motor starting. The AC-1 rating is the headline number: at 2600 A and up to 1000 V AC 50/60 Hz, this contactor handles continuous resistive loads without derating up to 40 °C ambient. Control is 110 V DC, with a pickup range of 0.85 to 1.1 Uc and dropout at 0.2 to 0.35 Uc at 55 °C. Closing takes 60 to 70 ms; opening 40 to 50 ms. Plate-mount only — no DIN rail at this frame size. ## Lifecycle reality — EOL phase, sourced to order This part is in end-of-life (EOL) phase per the manufacturer. The 2600 A AC-1 rating governs the continuous current through the power poles. Short-time withstand (Icw) is 12,000 A for 10 s, 9,000 A for 30 s — this tells you the contactor can ride through a fault long enough for an upstream fuse or breaker to clear, provided the associated fuse is rated 2500 A gG at ≤440 V. Breaking capacity is 3,900 A per IEC 60947-4-1. Heat dissipation is 40 W total (250 W per pole in AC-1 duty), so panel ventilation matters at this current level. Rated impulse withstand voltage is 8 kV, overvoltage category III — suitable for fixed-installation distribution boards. ## Mounting and wiring — plate mount, bar terminals Mounts on a plate (not DIN rail). Dimensions: 519 mm wide, 382 mm high, 251 mm deep. Power connections are via bar — three cables or busbar cross-section 100 x 10 mm, torqued to 58 N.m. Control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid, torqued to 1.2 N.m. IP20 front face with shrouds per IEC 60529 and VDE 0106. TH protective treatment for tropical environments. Operating altitude up to 3,000 m without derating. Listed to EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Rated insulation voltage 1000 V per both IEC and UL. The standards package covers most global markets — Europe (EN/IEC), North America (UL/CSA), and Japan (JIS). No RoHS/REACH statement is in the evidence, but Schneider typically provides declarations on request.","metaTitle":"Schneider TeSys F LC1F2600FD Contactor, 2600 A AC-1, 110 VDC","metaDescription":"Schneider Electric TeSys F LC1F2600FD 3-pole contactor. 2600 A AC-1 resistive load rating, 110 VDC coil. EOL phase. Sourced to order against RFQ. EN/IEC/UL/CSA listed.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"251 mm","Range":"TeSys","Width":"519 mm","Height":"382 mm","Standards":"EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"60...70 ms closing 40...50 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"40 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2600 A 50 Hz","Device short name":"LC1F","Inrush power in W":"2600 W (at 20 °C)","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Operating altitude":"3000 m without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2500 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) - busbar cross section: 100 x 10 mm","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3900 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"250 W AC-1","[Uc] control circuit voltage":"110 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.2...0.35 Uc (at 55 °C)","Hold-in power consumption in W":"18 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2600 A (at <60 °C) AC AC-1","[Ue] rated operational voltage":"<= 1000 V AC 50/60 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"12000 A 40 °C - 10 s 9000 A 40 °C - 30 s 7000 A 40 °C - 1 min 6000 A 40 °C - 3 min 4000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2600 A (at 60 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ce6799e1277690eba852949c02450789.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F2600FD/tesys-f-contactor-3p-3-no-ac1-1000-v-ac-2600-a-coil-110-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2600FD/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2600FD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2600FD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}