{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2600GD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2600GD","canonicalUrl":"https://aoctrl.com/schneider/LC1F2600GD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2600GD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2600GD, 3-pole contactor, 2600 A AC-1, 125 VDC control circuit, plate mount, EOL phase.","salesMarkdown":"The LC1F2600GD is a 3-pole TeSys F contactor rated 2600 A in AC-1 utilisation category — that's resistive loads like heaters or large lighting banks, not motor starting. The AC-1 rating is the headline number; for motor duty (AC-3) you'd need a different frame. The 125 VDC coil holds between 0.85 and 1.1 Uc at 55 °C and drops out between 0.2 and 0.35 Uc, so verify your control supply stays within that band. Closing takes 60 to 70 ms, opening 40 to 50 ms — fast enough for most resistive switching but not for arc-sensitive loads that need zero-crossing. Rated breaking capacity is 3900 A per IEC 60947-4-1, and short-time withstand (Icw) is 12 kA for 10 s at 40 °C — that tells you the contactor can ride through a fault long enough for an upstream breaker to clear. The associated fuse recommendation is 2500 A gG at ≤ 440 V. Rated insulation voltage is 1000 V, impulse withstand 8 kV, overvoltage category III. That puts it in the heavy industrial panel class. Mounts on a plate — not DIN rail. Dimensions are 519 mm wide, 382 mm high, 251 mm deep. That's a large footprint; plan the panel layout accordingly. Power circuit connections use bars with a busbar cross-section of 100 x 10 mm, three cables. Control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid. Tightening torque is 58 N.m on the power circuit, 1.2 N.m on the control circuit. IP20 front face with shrouds per IEC 60529 and VDE 0106. Heat dissipation is 40 W total, with 250 W per pole in AC-1 duty. That's significant — ensure adequate ventilation or forced cooling in the enclosure. Altitude rating is 3000 m without derating. Maximum operating rate is 600 cycles per hour at 55 °C. Complies with IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Protective treatment is TH (tropicalised). The contactor is rated for resistive load application per its AC-1 utilisation category.","metaTitle":"Schneider Electric LC1F2600GD TeSys F Contactor, 2600 A AC-1","metaDescription":"Schneider Electric LC1F2600GD TeSys F contactor. 2600 A AC-1 rated operational current, 125 VDC coil. EOL phase. Sourced to order against RFQ. Complies with IEC 60947-4-1, UL 60947","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"251 mm","Range":"TeSys","Width":"519 mm","Height":"382 mm","Standards":"EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"60...70 ms closing 40...50 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"40 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2600 A 50 Hz","Device short name":"LC1F","Inrush power in W":"2600 W (at 20 °C)","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Operating altitude":"3000 m without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2500 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) - busbar cross section: 100 x 10 mm","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3900 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"250 W AC-1","[Uc] control circuit voltage":"125 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.2...0.35 Uc (at 55 °C)","Hold-in power consumption in W":"18 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2600 A (at <60 °C) AC AC-1","[Ue] rated operational voltage":"<= 1000 V AC 50/60 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"12000 A 40 °C - 10 s 9000 A 40 °C - 30 s 7000 A 40 °C - 1 min 6000 A 40 °C - 3 min 4000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2600 A (at 60 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/41ce38f1b7ea830e0ae5ae2d1efed00b.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F2600GD/tesys-f-contactor-3p-3-no-ac1-1000-v-ac-2600-a-coil-125-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2600GD/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC1F2600GD in the TeSys F family?","answer":"The evidence does not list an official successor order code. A parametric substitute from the TeSys F range with the same frame size, pole count, and coil voltage would be the closest match, but no direct pin-compatible replacement is documented. Confirm fit with the manufacturer or a distributor before substituting."},{"question":"What compliance documentation does Schneider provide for LC1F2600GD?","answer":"The contactor complies with IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Protective treatment is TH (tropicalised). Standard documentation includes the datasheet and declaration of conformity for these standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2600GD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2600GD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}