{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2600M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2600M7","canonicalUrl":"https://aoctrl.com/schneider/LC1F2600M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2600M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, contactor, LC1F2600M7, 3-pole, 2600 A AC-1, 220 VAC 40-400 Hz coil, plate mount, IP20 front face.","salesMarkdown":"## Rated Operational Current and Application The LC1F2600M7: This contactor is rated for a continuous operational current of 2600 A in AC-1 utilization category (resistive load) at up to 60 °C ambient. The AC-1 rating means it is designed for switching resistive loads such as heating elements, lighting banks, or power distribution — not for motor starting (which would be AC-3 or AC-4). The 2600 A figure governs the main power circuit sizing; the associated fuse recommendation is 2500 A gG at ≤ 440 V. For a panel-builder, this dictates busbar cross-section: the power circuit connection accepts a bar with up to 3 cables or a busbar cross-section of 100 x 10 mm. ## Control Circuit and Coil Specifications The control circuit operates on 220 V AC at 40-400 Hz. The coil draws 2500 VA inrush at 20 °C and holds at 45 VA. The operational voltage limits are 0.85 to 1.1 Uc (187 to 242 V AC) at 55 °C; dropout occurs between 0.3 and 0.5 Uc (66 to 110 V AC). The control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid wire. For a commissioning engineer, verifying the control voltage is within these limits is essential to avoid coil burn-out or failure to pick up. ## Standards Compliance and Protection The LC1F2600M7 is certified to EN 60947-4-1, IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1, which are the governing standards for contactors and motor-starters. The front face is rated IP20 with shrouds per IEC 60529 and VDE 0106, meaning it provides finger protection but is not sealed against moisture. The protective treatment is TH (tropicalized) for humid environments. For a compliance buyer, the full set of certifications is documented and verifiable. ## Mounting and Physical Integration This contactor is designed for plate mounting — not DIN-rail. The dimensions are 519 mm width, 382 mm height, and 251 mm depth. The power circuit terminals require a tightening torque of 58 N.m, which is substantial and demands a torque wrench during installation. The control circuit terminals require only 1.2 N.m. For a panel OEM, the plate-mount requirement and the large footprint mean enclosure sizing must account for this unit's physical envelope and the busbar bending radius. ## Thermal Management and Operating Limits Total heat dissipation is 40 W, with 250 W per pole in AC-1 duty. The average impedance is 0.1 mOhm at 2600 A and 50 Hz. The rated short-time withstand current (Icw) is 12,000 A for 10 seconds at 40 °C, derating to 4,000 A for 10 minutes. The maximum operating rate is 600 cycles per hour at 55 °C. Ambient temperature range for operation is -5 to 40 °C; storage range is -60 to 80 °C. For a site electrical engineer, these thermal figures determine the need for forced ventilation or derating in high-ambient enclosures.","metaTitle":"Schneider Electric LC1F2600M7 TeSys F Contactor, 2600 A AC-1","metaDescription":"Schneider Electric LC1F2600M7 TeSys F contactor, 2600 A AC-1 rated operational current, 220 VAC 40-400 Hz coil. Certified to EN/IEC/UL 60947-4-1. End-of-life status; sourced to ord","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"251 mm","Width":"519 mm","Height":"382 mm","Current":"2600 A (at <60 °C) AC AC-1","Voltage":"<= 1000 V AC 50/60 Hz","Application":"Resistive load","Coil Voltage":"220 V AC 40...400 Hz","Operating Time":"40...80 ms closing 100...200 ms opening","Product Status":"End of Life","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Breaking Capacity":"3900 A conforming to IEC 60947-4-1","Insulation Voltage Ui":"1000 V conforming to IEC 60947-4-1 1000 V conforming to UL 60947-4-1","Temp Operating Max":"40 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-60...80 °C","Control Circuit Type":"AC at 40...400 Hz","Utilization Category":"AC-1","Main Product Or Component Type":"Contactor","Ambient Air Temperature Operation":"-5...40 °C","Permissible Ambient Air Temperature Around The Device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4bef788d4896e166b30baa84641c55a.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F2600M7/tesys-f-contactor-3p-3-no-ac1-1000-v-ac-2600-a-coil-220-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2600M7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2600M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2600M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}