{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2600Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2600Q7","canonicalUrl":"https://aoctrl.com/schneider/LC1F2600Q7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2600Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2600Q7, 3-pole contactor, 2600 A AC-1, 380 V AC 40-400 Hz coil, plate mount, EOL phase.","salesMarkdown":"## What the 2600 A AC-1 rating means for your panel At 2600 A continuous, the 0.1 mOhm average impedance per pole (at 50 Hz) means about 250 W dissipation per pole, so 40 W total heat shed to the enclosure. That heat has to go somewhere — plate-mount it on a steel backplate with enough surface area, not DIN rail, and keep ambient under 40 °C. The 3 NO power poles handle the full current; control is a 380 V AC coil (40-400 Hz) drawing 2500 VA inrush, 45 VA sealed. At 55 °C the coil holds between 0.85 and 1.1 Uc; dropout is 0.3 to 0.5 Uc. ## Mounting, wiring, and thermal derating Plate-mount only — no DIN-rail option. Dimensions: 519 mm wide, 382 mm high, 251 mm deep. Power circuit uses bar connections: three cables per pole, busbar cross-section up to 100 x 10 mm. Torque power terminals to 58 N.m; control circuit screw clamps take 1 to 4 mm² flexible or solid, torqued to 1.2 N.m. The IP20 front face (with shrouds) keeps fingers out but expects enclosure protection for anything wet. Short-time withstand: 12 kA for 10 s, 9 kA for 30 s, 7 kA for 1 min — useful for coordination studies. Associated fuse: 2500 A gG at ≤ 440 V. ## Standards and approvals — what the certs cover Certified to EN/IEC 60947-4-1 (contactors and motor-starters), EN/IEC 60947-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Overvoltage category III, rated insulation voltage 1000 V (both IEC and UL), impulse withstand 8 kV. Protective treatment TH (tropicalised). Breaking capacity 3900 A per IEC 60947-4-1. The AC-1 rating is the headline — this is not a motor-starting contactor (that would be AC-3 or AC-4). It is built for resistive load switching at high continuous current.","metaTitle":"Schneider TeSys F LC1F2600Q7 Contactor, 2600 A AC-1, 3P, EOL","metaDescription":"Schneider TeSys F LC1F2600Q7 3-pole contactor. 2600 A AC-1, 380 V AC coil, 1000 V insulation. EOL stage — sourced to order against RFQ. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"251 mm","Range":"TeSys","Width":"519 mm","Height":"382 mm","Standards":"EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"40...80 ms closing 100...200 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"40 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2600 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Inrush power in VA":"2500 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2500 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) - busbar cross section: 100 x 10 mm","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3900 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"250 W AC-1","[Uc] control circuit voltage":"380 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2600 A (at <60 °C) AC AC-1","[Ue] rated operational voltage":"<= 1000 V AC 50/60 Hz","Hold-in power consumption in VA":"45 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"12000 A 40 °C - 10 s 9000 A 40 °C - 30 s 7000 A 40 °C - 1 min 6000 A 40 °C - 3 min 4000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2600 A (at 60 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cb6e5a137ada22277e6274e9ee1ba8a6.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1F2600Q7/tesys-f-contactor-3p-3-no-ac1-1000-v-ac-2600-a-coil-380-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2600Q7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC1F2600Q7 in the TeSys F family?","answer":"The evidence does not list an official successor order code. For a drop-in replacement, verify the mounting footprint (plate mount, 519 x 382 x 251 mm), the 2600 A AC-1 rating, and the 380 V AC coil voltage with your Schneider representative or cross-reference the TeSys F catalog for a current-production equivalent."},{"question":"What compliance documentation does Schneider provide for LC1F2600Q7?","answer":"The contactor carries UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC 60947-4-1, and JIS C8201-4-1 certifications. Protective treatment is TH (tropicalised). RoHS and REACH declarations are standard from Schneider for this series — request them with your RFQ."},{"question":"Where can I buy LC1F2600Q7 and how is it quoted?","answer":"This part is sourced through independent distribution channels. Submit an RFQ for current pricing and availability — both are confirmed at quote time. No stock count or lead-time figure is carried here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2600Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2600Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}