{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2600RD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2600RD","canonicalUrl":"https://aoctrl.com/schneider/LC1F2600RD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2600RD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2600RD, 3-pole contactor, 2600 A AC-1, 440 VDC control, plate mount, EOL phase-out.","salesMarkdown":"## What the 2600 A AC-1 rating means for your load For motor duty you'd need an AC-3 or AC-4 rated device; this one is spec'd for continuous resistive switching at up to 1000 V AC 50/60 Hz. The 440 V DC control coil pulls 18 W hold-in power at 20 °C, with an operating range of 0.85...1.1 Uc and drop-out between 0.2...0.35 Uc at 55 °C. ## Integration — plate mount, bar terminals, thermal management Mounting is plate-only — no DIN-rail option on this frame size. The power circuit uses bar terminals accepting up to three 100 x 10 mm busbars per pole; control circuit uses screw clamp terminals accepting 1...4 mm² flexible or solid. At 2600 A AC-1, heat dissipation runs 40 W total (250 W per pole), so panel ventilation or forced air is expected. The IP20 front face with shrouds meets IEC 60529 and VDE 0106 for finger-safe touch protection. ## Breaking capacity and short-time withstand Rated breaking capacity is 3900 A per IEC 60947-4-1. Short-time withstand (Icw) is 12 kA for 10 s, 9 kA for 30 s, 7 kA for 1 min, 6 kA for 3 min, and 4 kA for 10 min — all at 40 °C. Associated fuse rating is 2500 A gG at ≤ 440 V. These numbers define the upstream protection coordination: the contactor can ride through a fault for the listed durations without welding, but the fuse must clear before the Icw limit is exceeded. Certified to EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. Rated insulation voltage (Ui) is 1000 V per IEC and UL. Impulse withstand (Uimp) is 8 kV, overvoltage category III. Protective treatment is TH (tropicalised).","metaTitle":"Schneider Electric LC1F2600RD TeSys F Contactor, 2600 A AC-1","metaDescription":"Schneider Electric LC1F2600RD TeSys F contactor, 2600 A AC-1 rated operational current, 440 VDC control, 3-pole. EOL phase-out; sourced to order against RFQ. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"251 mm","Range":"TeSys","Width":"519 mm","Height":"382 mm","Standards":"EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"60...70 ms closing 40...50 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"40 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2600 A 50 Hz","Device short name":"LC1F","Inrush power in W":"2600 W (at 20 °C)","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Operating altitude":"3000 m without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2500 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) - busbar cross section: 100 x 10 mm","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3900 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"250 W AC-1","[Uc] control circuit voltage":"440 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.2...0.35 Uc (at 55 °C)","Hold-in power consumption in W":"18 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2600 A (at <60 °C) AC AC-1","[Ue] rated operational voltage":"<= 1000 V AC 50/60 Hz","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"12000 A 40 °C - 10 s 9000 A 40 °C - 30 s 7000 A 40 °C - 1 min 6000 A 40 °C - 3 min 4000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2600 A (at 60 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/77866f1ea418de0c524fa6c2bc62de65.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1F2600RD/tesys-f-contactor-3p-3-no-ac1-1000-v-ac-2600-a-coil-440-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2600RD/alternatives.json"},"ai":{"faq":[{"question":"What is LC1F2600RD's depth?","answer":"The listed depth is 251 mm, width 519 mm, height 382 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2600RD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2600RD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}