{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2600V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2600V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F2600V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2600V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2600V7, 3-pole contactor, 2600 A AC-1, 400 V AC 50/60 Hz coil, plate mount, IP20 front face.","salesMarkdown":"## What the 2600 A AC-1 Rating Means for Your BOM The LC1F2600V7 is a 3-pole contactor from the TeSys F range, rated for 2600 A in AC-1 utilisation category at <60 °C. That AC-1 rating governs resistive loads — heating elements, furnaces, lighting banks — where the current waveform is nearly sinusoidal and inrush is minimal. For motor duty (AC-3 or AC-4), the contactor must be derated per the manufacturer's curves; the 2600 A figure is not the motor-switching current. The coil is 400 V AC 40...400 Hz, with an inrush of 2500 VA and a hold-in of 45 VA at 20 °C. Per the specification, the control circuit voltage limits are 0.85...1.1 Uc for operation and 0.3...0.5 Uc for drop-out at 55 °C. ## Mounting and Integration — Plate-Mount, Not DIN Rail Mounting support is plate, not DIN rail. The contactor measures 519 mm wide, 382 mm high, and 251 mm deep. Power circuit connections use bar terminals accepting up to three cables per pole with a busbar cross-section of 100 x 10 mm. Control circuit connections are screw clamp terminals accepting 1...4 mm² flexible or solid cable. Tightening torque is 58 N.m on the power circuit and 1.2 N.m on the control circuit. The IP20 front face with shrouds (per IEC 60529 and VDE 0106) provides basic finger protection but is not rated for washdown environments. ## Electrical Performance and Protection Coordination Rated insulation voltage is 1000 V per IEC 60947-4-1 and UL 60947-4-1. Rated impulse withstand voltage is 8 kV, overvoltage category III. The rated breaking capacity is 3900 A per IEC 60947-4-1. Short-time withstand current (Icw) is 12,000 A for 10 s, 9000 A for 30 s, 7000 A for 1 min, 6000 A for 3 min, and 4000 A for 10 min at 40 °C. The associated fuse rating is 2500 A gG at ≤440 V. Operating time is 40...80 ms closing and 100...200 ms opening. Maximum operating rate is 600 cycles per hour at 55 °C. Heat dissipation is 40 W total, with 250 W per pole in AC-1 duty. The contactor is compliant with EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1.","metaTitle":"Schneider Electric LC1F2600V7 TeSys F Contactor, 2600 A AC-1","metaDescription":"Schneider Electric LC1F2600V7 TeSys F contactor, 2600 A AC-1 rated operational current, 3-pole, 400 V AC 50/60 Hz coil. End-of-life status; sourced to order against RFQ. Compliant","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"251 mm","Range":"TeSys","Width":"519 mm","Height":"382 mm","Standards":"EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"40...80 ms closing 100...200 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"40 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.1 mOhm - Ith 2600 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 58 N.m","Compatibility code":"LC1F","Inrush power in VA":"2500 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Associated fuse rating":"2500 A gG at <= 440 V","Maximum operating rate":"600 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 3 cable(s) - busbar cross section: 100 x 10 mm","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3900 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"250 W AC-1","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1000 V conforming to UL 60947-4-1","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"2600 A (at <60 °C) AC AC-1","[Ue] rated operational voltage":"<= 1000 V AC 50/60 Hz","Hold-in power consumption in VA":"45 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"12000 A 40 °C - 10 s 9000 A 40 °C - 30 s 7000 A 40 °C - 1 min 6000 A 40 °C - 3 min 4000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"2600 A (at 60 °C)","Permissible ambient air temperature around the device":"-40...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1e64a2ae47a33b391635dd6f6dba1046.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC1F2600V7/tesys-f-contactor-3p-3-no-ac1-1000-v-ac-2600-a-coil-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2600V7/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LC1F2600V7?","answer":"Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront for a current quotation; the part is sourced through independent distribution channels."},{"question":"What compliance documentation does Schneider Electric provide for LC1F2600V7?","answer":"The contactor is compliant with EN 60947-4-1, IEC 60947-1, IEC 60947-4-1, JIS C8201-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. The protective treatment is TH (tropicalised)."},{"question":"What are the key ratings of LC1F2600V7?","answer":"Rated operational current is 2600 A AC-1 at <60 °C. Rated operational voltage is ≤1000 V AC 50/60 Hz. Control circuit voltage is 400 V AC 40...400 Hz. Rated breaking capacity is 3900 A per IEC 60947-4-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2600V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2600V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}