{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F2654X7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F2654X7","canonicalUrl":"https://aoctrl.com/schneider/LC1F2654X7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F2654X7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F2654X7, 4-pole contactor, 350 A AC-1 at ≤440 V, AC control 550-600 V, end-of-life phase.","salesMarkdown":"## What the 350 A AC-1 rating means for fit The LC1F2654X7 is a 4-pole (4 NO) contactor from the TeSys F range, rated 350 A at ≤440 V in utilisation category AC-1 — that is the resistive-load curve, not motor starting. The AC-1 rating governs continuous current through resistive heaters, lighting banks, or transformer primaries where inrush is low. For motor duty (AC-3), this contactor is not the right pick; the 350 A figure applies only to the AC-1 band per IEC 60947-4-1. Power dissipation runs 37 W per pole in AC-1 service, with total heat rejection of 8 W from the coil at hold-in. The control circuit is AC 550-600 V at 40-400 Hz, with an inrush of 650 VA dropping to 10 VA sealed. ## Mounting and integration constraints Mounts to a plate — no DIN-rail clip on this frame. Dimensions are 8.4 in deep by 9.6 in wide by 8.0 in high (213 x 244.5 x 203 mm). Power connections are bolted bar (32 x 4 mm) or lug-ring terminals accepting up to 240 mm² cable. Control wiring uses screw-clamp terminals sized for 1-4 mm² flexible or solid. Tightening torque: 1.2 N·m on the control circuit, 35 N·m on the power circuit. Operating altitude is 3000 m without derating; storage temperature range -60 to 80 °C. ## Protection coordination and ratings Associated fuse rating is 315 A aM or 400 A gG at ≤440 V. Rated breaking capacity is 2120 A per IEC 60947-4-1. Insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 group C. Overvoltage category III. Mechanical durability is 10 million cycles; maximum operating rate is 2400 cycles per hour at 55 °C. Operating time: 40-65 ms closing, 100-170 ms opening. Protective treatment is TH (tropicalised) for humid environments.","metaTitle":"Schneider LC1F2654X7 TeSys F Contactor, 350 A AC-1, 4P, EOL","metaDescription":"Schneider Electric LC1F2654X7 TeSys F contactor, 350 A rated operational current AC-1 at ≤440 V, 4 NO poles. End-of-life phase; sourced to order against RFQ. IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"8.4 in (213 mm)","Range":"TeSys","Width":"9.6 in (244.5 mm)","Height":"8.0 in (203 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Standards":"IEC 60947-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1 IEC 60947-4-1","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"8 W","Mounting Support":"Plate","Range of Product":"TeSys F","Average impedance":"0.3 mOhm - Ith 350 A 50 Hz","Device short name":"LC1F","Poles description":"4P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)","Compatibility code":"LC1F","Inrush power in VA":"650 VA, 40...400 Hz 0.9 68 °F (20 °C))","Operating altitude":"9842.52 ft (3000 m) without derating","Control circuit type":"AC 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"315 A aM at 400 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bar 2 32 x 4 mm Power circuit lugs-ring terminals 1 0.4 in² (240 mm²) Power circuit connector 1 0.4 in² (240 mm²) Power circuit bolted connection","IP degree of protection":"IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Product or Component Type":"Contactor","Power dissipation per pole":"37 W AC-1","[Uc] control circuit voltage":"550...600 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.15...0.2 Uc 40...400 Hz 131 °F (55 °C))","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"10 VA, 40...400 Hz 0.9 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e0003caab18089935f0a590e8570f245.pdf","sourceUrl":"https://www.se.com/th/en/product/LC1F2654X7/tesys-f-contactor-4p-4-no-ac1-440-v-350-a-coil-550-600-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F2654X7/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications of LC1F2654X7?","answer":"Rated operational current 350 A at ≤440 V AC in utilisation category AC-1 (resistive load). Four normally open poles. Control circuit voltage 550-600 V AC at 40-400 Hz. Rated insulation voltage 1000 V per IEC 60947-4-1. Mechanical durability 10 million cycles. Dimensions 8.4 x 9.6 x 8.0 in (213 x 244.5 x 203 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F2654X7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F2654X7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}