{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F265V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F265V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F265V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F265V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F265V7, 3-pole contactor, 265 A AC-3 rated operational current, 400 V AC coil, end-of-life phase.","salesMarkdown":"The Schneider Electric TeSys F LC1F265V7 is a 3-pole direct on-line contactor rated for 265 A in AC-3 duty at ≤ 440 V, making it the right fit for switching motor loads up to 132 kW at 380–400 V or 160 kW at 500 V. The 400 V AC coil draws 650 VA inrush at 20 °C and holds across 0.85–1.1 Uc; dropout triggers between 0.15–0.2 Uc. This contactor is in its end-of-life phase, so sourcing is through independent distribution channels against an RFQ. AC-3 duty covers starting and running of squirrel-cage motors; the contactor also carries AC-1 (resistive) and AC-4 (plugging/inching) categories, so it covers a range of load types. The 132 kW at 400 V is the motor power you can switch in a standard 400 V three-phase system; at 500 V that climbs to 160 kW. The 400 V AC coil is fixed — no dual-voltage or DC option here — so your control circuit must supply 400 V AC at 40–400 Hz. The LC1F265V7 is designed and certified to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, and JIS C8201-4-1. The rated insulation voltage is 1000 V per IEC 60947-4-1, and the rated breaking capacity is 2120 A per the same standard. Overvoltage category III applies. The front face carries IP20 protection with shrouds, conforming to IEC 60529 and VDE 0106 — sufficient for finger-safe installation inside a panel. Mounting is plate-based — no DIN-rail clip on this frame size. The contactor measures 203 mm high, 201.5 mm wide, and 213 mm deep, so plan for a backplate footprint of roughly 200 × 200 mm plus clearance for power and control wiring. Power connections accept bar (up to 32 × 4 mm busbar), ring lugs up to 240 mm², or bolted connections. Control wiring uses screw-clamp terminals accepting 1–4 mm² flexible or solid. Tightening torque is 1.2 N·m on the control circuit and 35 N·m on the power circuit.","metaTitle":"Schneider TeSys F LC1F265V7 Contactor, 265 A AC-3, 400 V Coi","metaDescription":"Schneider Electric TeSys F LC1F265V7 3-pole contactor. 265 A AC-3 rated operational current, 132 kW at 400 V. 400 V AC coil. End-of-life phase. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"213 mm","Range":"TeSys","Width":"201.5 mm","Height":"203 mm","Standards":"IEC 60947-1 JIS C8201-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-4-1","Motor power kW":"132 kW at 380...400 V AC 50/60 Hz (AC-3) 140 kW at 415 V AC 50/60 Hz (AC-3) 140 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 660...690 V AC 50/60 Hz (AC-3) 147 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 220...230 V AC 50/60 Hz (AC-3) 51 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"8 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.3 mOhm - Ith 350 A 50 Hz","Device short name":"LC1F","Motor Power Range":"55...100 kW at 200...240 V 3 phases 110...220 kW at 480...500 V 3 phases 110...220 kW at 380...440 V 3 phases","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Inrush power in VA":"650 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Motor starter type":"Direct on-line contactor","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"315 A aM at 400 A gG at <= 440 V","Contactor coil voltage":"400 V AC standard","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: connector 1 cable(s) 240 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"37 W AC-1 21 W AC-3","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.15...0.2 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"350 A (at 265 A (at <55 °C) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 40 °C - 10 s 1230 A 40 °C - 30 s 950 A 40 °C - 1 min 620 A 40 °C - 3 min 480 A 40 °C - 10 min","[Ith] conventional free air thermal current":"350 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/03f9682df27ef424ee87b82c2e1929d3.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC1F265V7/tesys-f-contactor-3p-3-no-ac3-440-v-265-a-coil-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F265V7/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the LC1F265V7 and get a price?","answer":"The LC1F265V7 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a current quote."},{"question":"What motor power can the LC1F265V7 switch at 400 V?","answer":"At 380–400 V AC in AC-3 duty, the LC1F265V7 switches motor loads up to 132 kW. At 415 V and 440 V, the rating increases to 140 kW."},{"question":"What is the rated operational current of the LC1F265V7?","answer":"The rated operational current (Ie) is 265 A in AC-3 duty at ≤ 440 V and ≤ 55 °C. The thermal current (Ith) is 350 A at 50 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F265V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F265V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}