{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F330M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F330M7","canonicalUrl":"https://aoctrl.com/schneider/LC1F330M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F330M7","rawCanonicalId":null},"summary":{"shortDescription":"CONTACTOR 600VAC 330AMP IEC +OPTIONS|CONTACTOR 600VAC 330AMP IEC +OPTIONS","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"8.6 in (219 mm)","Range":"TeSys","Width":"8.4 in (213 mm)","Height":"8.1 in (206 mm)","Category":"US10I1222336","Standards":"EN 60947-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1","Motor power kW":"160 kW at 380...400 V AC 50/60 Hz (AC-3) 180 kW at 415 V AC 50/60 Hz (AC-3) 200 kW at 440 V AC 50/60 Hz (AC-3) 200 kW at 500 V AC 50/60 Hz (AC-3) 220 kW at 660...690 V AC 50/60 Hz (AC-3) 160 kW at 1000 V AC 50/60 Hz (AC-3) 100 kW at 220...230 V AC 50/60 Hz (AC-3) 59 kW at 400 V AC 50/60 Hz (AC-4)","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"8 W","Mounting Support":"Plate","Range of Product":"TeSys F","Average impedance":"0.28 mOhm - Ith 400 A 50 Hz","Device short name":"LC1F","Motor Power Range":"55...100 kW 200...240 V 3 phase 110...220 kW 480...500 V 3 phase 110...220 kW 380...440 V 3 phase","Poles description":"3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)","Compatibility code":"LC1F","Inrush power in VA":"650 VA, 40...400 Hz 0.9 68 °F (20 °C))","Motor starter type":"Direct on-line contactor","Operating altitude":"9842.52 ft (3000 m) without derating","Control circuit type":"AC 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Motor control Resistive load","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A aM at 500 A gG at <= 440 V","Contactor coil voltage":"220 V AC standard","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit lugs-ring terminals 1 0.4 in² (240 mm²) Power circuit bar 2 30 x 5 mm Power circuit bolted connection","IP degree of protection":"IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106","Rated breaking capacity":"2640 A conforming to IEC 60947-4-1","Product or Component Type":"Contactor","Power dissipation per pole":"44 W AC-1 31 W AC-3","[Uc] control circuit voltage":"220 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 40...400 Hz 131 °F (55 °C))","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"400 A (at 330 A (at <131 °F (55 °C)) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"10 VA, 40...400 Hz 0.9 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2650 A 104 °F (40 °C) - 10 s 1800 A 104 °F (40 °C) - 30 s 1300 A 104 °F (40 °C) - 1 min 900 A 104 °F (40 °C) - 3 min 750 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"400 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ebf589818afd93db1bf354d9502c52b6.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F330M7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F330M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F330M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}