{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F400VD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F400VD","canonicalUrl":"https://aoctrl.com/schneider/LC1F400VD","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F400VD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor, LC1F400VD, 3-pole, 400 VDC coil, 500 A AC-3 rated, 200 kW at 400 V AC-3, plate mount, EOL hot.","salesMarkdown":"The Schneider Electric LC1F400VD is a TeSys F three-pole contactor with a 400 VDC coil, rated for motor and resistive loads across AC-1, AC-3, and AC-4 utilisation categories. It switches up to 500 A in AC-3 duty at 440 V, translating to 200 kW at 400 V or 220 kW at 415 V — a heavy-duty machine-tool or pump contactor for a 200 kW class motor. The 400 VDC coil is uncommon; most TeSys F contactors run AC or lower DC coils, so verify your control voltage matches before committing the BOM line. This part carries an EOL hot lifecycle marker. The manufacturer has flagged end-of-life but the part is still in the supply chain for last-time buys. The 500 A AC-3 rating (at 440 V, 55 °C) is the headline number for motor switching — it governs the contactor's ability to make and break locked-rotor current. The AC-4 rating (75 kW at 400 V) matters if you need to reverse or plug the motor in-cycle, where the contactor must interrupt full-load current repeatedly. Plate-mount only — no DIN-rail clip on this frame size. The power circuit uses bolted connections or ring lugs (up to 150 mm² cable or 30 x 5 mm busbar). Control circuit terminals are screw clamp, accepting 1 to 4 mm² flexible or solid. Tightening torque for the power circuit is 35 N.m — substantial, so a torque wrench is expected. IP20 with shrouds on the front face, so it needs a panel or enclosure to meet touch-safe requirements. Certified to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1, overvoltage category III. The 400 VDC coil has operational limits of 0.85 to 1.1 Uc and drop-out at 0.2 to 0.35 Uc — ensure your DC supply stays within that window, especially under brownout conditions.","metaTitle":"Schneider LC1F400VD TeSys F Contactor, 400 VDC Coil, 500 A A","metaDescription":"Schneider Electric LC1F400VD TeSys F contactor. 400 VDC coil, 500 A AC-3 rated, 200 kW at 400 V. EOL hot – sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"219 mm","Range":"TeSys","Width":"213 mm","Height":"206 mm","Standards":"JIS C8201-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1","Motor power kW":"75 kW at 400 V AC 50/60 Hz (AC-4) 200 kW at 380...400 V AC 50/60 Hz (AC-3) 220 kW at 415 V AC 50/60 Hz (AC-3) 250 kW at 440 V AC 50/60 Hz (AC-3) 257 kW at 500 V AC 50/60 Hz (AC-3) 280 kW at 660...690 V AC 50/60 Hz (AC-3) 185 kW at 1000 V AC 50/60 Hz (AC-3) 110 kW at 220...230 V AC 50/60 Hz (AC-3)","Operating time":"50...60 ms closing 45...60 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"6 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.26 mOhm - Ith 500 A 50 Hz","Device short name":"LC1F","Inrush power in W":"1000 W (at 20 °C)","Poles description":"3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Operating altitude":"3000 m without derating","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Associated fuse rating":"400 A aM at 500 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm Power circuit: lugs-ring terminals 2 cable(s) 150 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3200 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"65 W AC-1 42 W AC-3","[Uc] control circuit voltage":"400 V DC","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at 55 °C) Drop-out: 0.2...0.35 Uc (at 55 °C)","Hold-in power consumption in W":"6 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"500 A (at 400 A (at <55 °C) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 460 V DC","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"3600 A 40 °C - 10 s 2400 A 40 °C - 30 s 1700 A 40 °C - 1 min 1200 A 40 °C - 3 min 1000 A 40 °C - 10 min","[Ith] conventional free air thermal current":"500 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f7534604155f283cc03ba4cbae3d86fe.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1F400VD/tesys-f-contactor-3p-3-no-ac3-440-v-400-a-coil-400-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F400VD/alternatives.json"},"ai":{"faq":[{"question":"What is LC1F400VD's listed depth?","answer":"The depth is 219 mm."},{"question":"What compliance documentation does this brand provide for LC1F400VD?","answer":"The part is certified to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. The evidence does not list RoHS or REACH declarations specifically, but Schneider Electric typically provides these on request for TeSys products. Contact us with your RFQ for documentation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F400VD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F400VD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}