{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F400X722L","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F400X722L","canonicalUrl":"https://aoctrl.com/schneider/LC1F400X722L","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F400X722L","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F400X722L, 3-pole contactor, 500 A rated operational current (AC-3), 550-600 VAC 40-400 Hz coil, plate mount.","salesMarkdown":"The Schneider Electric TeSys F LC1F400X722L is a 3-pole contactor rated for 500 A in AC-3 duty at ≤ 440 V, meaning it switches motor loads up to that current — in practice, a 200 kW motor at 400 V (AC-3) or a 75 kW motor in the heavier AC-4 category (plugging/reversing). It carries a 550-600 VAC 40-400 Hz coil, so it's built for 575 V control circuits common in North American panels. The contactor is plate-mounted, not DIN-rail, and measures 219 mm deep × 213 mm wide × 375 mm tall — plan for a backplate footprint roughly 8.4 × 14.8 inches. The 500 A AC-3 rating is the headline number, but the real-world motor capacity depends on voltage: 200 kW at 380-400 V, 220 kW at 415 V, 250 kW at 440 V, 257 kW at 500 V, 280 kW at 660-690 V, and 185 kW at 1000 V. For UL/CSA circuits, it's rated 250 hp at 460 V and 300 hp at 575 V. Mechanical durability is 10 million cycles, so it's built for high-cycle applications like conveyor or pump stations. Heat dissipation runs 14 W holding, 65 W per pole in AC-1 and 42 W per pole in AC-3 — account for that in enclosure thermal calculations. ## Mounting, connections, and environment Mounts on a plate (not DIN rail). Power connections are bolted, accepting two 30 × 5 mm bars or ring terminals up to 150 mm². Control circuit terminals are screw clamp, 1-4 mm² flexible or solid. Tightening torque: 35 N·m on the power side, 1.2 N·m on control. Protective treatment TH (tropicalized) for humid environments. Compliant with EN/IEC 60947-4-1 and EN/IEC 60947-1, plus JIS C8201-4-1. Rated insulation voltage 1000 V per IEC, 1500 V per VDE 0110 group C. Overvoltage category III. UL/CSA motor power ratings are listed, so it carries North American approvals for 200 V through 575 V systems.","metaTitle":"Schneider TeSys F LC1F400X722L Contactor, 500 A AC-3, 550-60","metaDescription":"Schneider TeSys F LC1F400X722L 3-pole contactor, 500 A AC-3, 200 kW at 400 V. End-of-life hot. Sourced to order against RFQ. UL/CSA, IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"8.6 in (219 mm)","Width":"8.4 in (213 mm)","Height":"14.8 in (375 mm)","Category":"39997-CANADIAN PRODUCTS","Standards":"EN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1","Motor power kW":"75 kW at 400 V AC 50/60 Hz (AC-4) 200 kW at 380...400 V AC 50/60 Hz (AC-3) 220 kW at 415 V AC 50/60 Hz (AC-3) 250 kW at 440 V AC 50/60 Hz (AC-3) 257 kW at 500 V AC 50/60 Hz (AC-3) 280 kW at 660...690 V AC 50/60 Hz (AC-3) 185 kW at 1000 V AC 50/60 Hz (AC-3) 110 kW at 220...230 V AC 50/60 Hz (AC-3)","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"14 W","Mounting Support":"Plate","Range of Product":"TeSys F","Average impedance":"0.26 mOhm - Ith 500 A 50 Hz","Device short name":"LC1F","Poles description":"3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)","Inrush power in VA":"1075 VA, 40...400 Hz 0.9 68 °F (20 °C))","Operating altitude":"9842.52 ft (3000 m) without derating","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Resistive load Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 11 ms Vibrations contactor open1.5 Gn, 5...300 Hz","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A aM at 500 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bolted connection Power circuit 2 bars 30 x 5 mm Power circuit lugs-ring terminals 2 0.2 in² (150 mm²)","IP degree of protection":"IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106","Rated breaking capacity":"3200 A conforming to IEC 60947-4-1","Product or Component Type":"Contactor","motor power HP (UL / CSA)":"100 hp at 200 V AC 125 hp at 230 V AC 250 hp at 460 V AC 300 hp at 575 V AC","Power dissipation per pole":"65 W AC-1 42 W AC-3","[Uc] control circuit voltage":"550...600 V AC 40...400 Hz","Auxiliary contact composition":"2 NO + 2 NC","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))","Power Pole Contact Composition":"3 NO","[Ie] rated operational current":"500 A (at 400 A (at <131 °F (55 °C)) at <= 440 V AC AC-3","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"15 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"3600 A 104 °F (40 °C) - 10 s 2400 A 104 °F (40 °C) - 30 s 1700 A 104 °F (40 °C) - 1 min 1200 A 104 °F (40 °C) - 3 min 1000 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"500 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/df21d3e0f2d65444c225564bc805f4a1.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1F400X722L/tesys-f-nonreversing-contactor-3p-open-600v-400a-600vac-40400hz-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1F400X722L/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of LC1F400X722L?","answer":"500 A rated operational current in AC-3 at ≤ 440 V, 550-600 VAC coil, 200 kW motor power at 400 V AC-3, 250 hp at 460 V UL/CSA, and a mechanical durability of 10 million cycles."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F400X722L","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F400X722L when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}