{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F5002P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F5002P7","canonicalUrl":"https://aoctrl.com/schneider/LC1F5002P7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F5002P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F series, LC1F5002P7 contactor, 2 NO power poles, 700 A rated operational current AC-1 at ≤440 V, 230 V AC 40-400 Hz control circuit, plate mount.","salesMarkdown":"The Schneider Electric TeSys F LC1F5002P7 is a 2-pole contactor rated for 700 A in AC-1 duty (resistive loads) at ≤440 V, with a 230 V AC control coil. It switches and disconnects resistive heating elements, furnace banks, or similar loads where inrush is minimal and the current waveform stays sinusoidal. The 2 NO power pole configuration means it makes and breaks both line conductors — no auxiliary contacts built into the main poles. Plate-mounted, not DIN-rail — the 233 mm width and 238 mm height require a drilled backplate or sub-panel, with bolted power connections accepting up to 240 mm² cable or 40 x 5 mm busbar. The IP20 front face (with shrouds) is touch-safe once installed inside an enclosure; no washdown rating here. Tightening torque on the power circuit is 35 N.m — a torque wrench is expected, not optional. ## Key electrical characteristics Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand of 8 kV (overvoltage category III). The contactor dissipates 18 W steady-state (88 W per pole in AC-1). Certified to EN 60947-4-1, IEC 60947-4-1, EN 60947-1, IEC 60947-1, and JIS C8201-4-1. The rated breaking capacity is 4000 A per IEC 60947-4-1. Protective treatment is TH (tropicalized).","metaTitle":"TeSys F LC1F5002P7 Contactor, 700 A AC-1, 2 NO, 230 V AC","metaDescription":"Schneider TeSys F LC1F5002P7 contactor, 700 A rated operational current AC-1, 2 NO poles, 230 V AC coil. EOL phase. Sourced to order. RFQ for current availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"232 mm","Range":"TeSys","Width":"233 mm","title":"LC1F5002P7","Height":"238 mm","Standards":"EN 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-1 IEC 60947-4-1","description":"TeSys F contactor - 2P (2 NO) - AC-1 - <= 440 V 700 A - coil 230 V AC","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"18 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.18 mOhm - Ith 700 A 50 Hz","Device short name":"LC1F","Poles description":"2P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Inrush power in VA":"1100 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"500 A aM at 800 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm Power circuit: lugs-ring terminals 2 cable(s) 240 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"4000 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"88 W AC-1","[Uc] control circuit voltage":"230 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"2 NO","[Ie] rated operational current":"700 A (at <40 °C) at <= 440 V AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4200 A 40 °C - 10 s 3200 A 40 °C - 30 s 2400 A 40 °C - 1 min 1500 A 40 °C - 3 min 1200 A 40 °C - 10 min","[Ith] conventional free air thermal current":"700 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/16a1ab76420c25da61bb2e24a8cbd33b.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1F5002P7/tesys-f-contactor-2p-2-no-ac1-440-v-700-a-coil-230-v-ac/"},"ai":{"faq":[{"question":"What is LC1F5002P7's listed depth?","answer":"232 mm. Combined with a width of 233 mm and height of 238 mm, it requires a plate-mounted footprint with bolted power connections."},{"question":"What compliance documentation does Schneider provide for LC1F5002P7?","answer":"The contactor is certified to EN 60947-4-1, IEC 60947-4-1, EN 60947-1, IEC 60947-1, and JIS C8201-4-1. The front face carries IP20 protection with shrouds per IEC 60529 and VDE 0106. Protective treatment is TH (tropicalized)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F5002P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F5002P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}