{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1F5002V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1F5002V7","canonicalUrl":"https://aoctrl.com/schneider/LC1F5002V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC1F5002V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC1F5002V7 contactor, 2-pole, 700 A AC-1, 400 V AC 50/60 Hz coil, plate mount, end-of-life status.","salesMarkdown":"That AC-1 rating means it's designed for resistive loads — heaters, ovens, lighting banks — where the current stays steady through the switching cycle, not the inductive inrush of a motor start. The coil pulls 400 V AC at 40 to 400 Hz, with an inrush of 1100 VA and a hold-in draw of 18 VA once the armature seals. This is a plate-mount contactor, not a DIN-rail snap-on. At 233 mm wide, 238 mm tall, and 232 mm deep, it needs a bolted-down footprint in the panel — plan for the 35 N·m torque spec on the power circuit connections and the bar or ring-lug terminations that handle the 700 A path. The headline number is 700 A at ≤40 °C in AC-1 duty. The associated fuse sizing is 500 A aM or 800 A gG at up to 440 V — a useful guardrail for the upstream protection. The closing time is 40 to 65 ms, opening 100 to 170 ms — that opening delay is inherent to the AC coil dropout characteristic. Heat dissipation runs 18 W for the coil and 88 W per pole in AC-1 service, so factor that into your enclosure thermal budget. The control circuit is screw-clamp terminals accepting 1 to 4 mm² flexible or solid wire. The power circuit uses bolted bar connections or ring lugs for up to 240 mm² cable — this is a high-current interface that needs proper lug crimping and the specified 35 N·m torque. ## Standards and environmental limits The contactor is certified to IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, with an impulse withstand voltage of 8 kV. Overvoltage category III. The front face with shrouds carries IP20 protection. Operating temperature range is -5 to 55 °C, storage from -60 to 80 °C, and it can operate at altitudes up to 3000 m without derating.","metaTitle":"Schneider TeSys F LC1F5002V7 Contactor, 700 A AC-1, 400 V Co","metaDescription":"Schneider Electric TeSys F LC1F5002V7 contactor. 700 A rated operational current (AC-1), 400 V AC 50/60 Hz coil. End-of-life status. Sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"232 mm","Range":"TeSys","Width":"233 mm","title":"LC1F5002V7","Height":"238 mm","Standards":"IEC 60947-1 IEC 60947-4-1 EN 60947-4-1 EN 60947-1 JIS C8201-4-1","description":"TeSys F contactor - 2P (2 NO) - AC-1 - <= 440 V 700 A - coil 400 V AC","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"eol_hot","Heat dissipation":"18 W","Mounting support":"Plate","Range of product":"TeSys F","Average impedance":"0.18 mOhm - Ith 700 A 50 Hz","Device short name":"LC1F","Poles description":"2P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Compatibility code":"LC1F","Inrush power in VA":"1100 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Control circuit type":"AC at 40...400 Hz","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"500 A aM at 800 A gG at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm Power circuit: lugs-ring terminals 2 cable(s) 240 mm² Power circuit: bolted connection","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"4000 A conforming to IEC 60947-4-1","Product or component type":"Contactor","Power dissipation per pole":"88 W AC-1","[Uc] control circuit voltage":"400 V AC 40...400 Hz","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)","Power Pole Contact Composition":"2 NO","[Ie] rated operational current":"700 A (at <40 °C) at <= 440 V AC AC-1","[Ue] rated operational voltage":"<= 460 V DC","Hold-in power consumption in VA":"18 VA, 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4200 A 40 °C - 10 s 3200 A 40 °C - 30 s 2400 A 40 °C - 1 min 1500 A 40 °C - 3 min 1200 A 40 °C - 10 min","[Ith] conventional free air thermal current":"700 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/76ae8791aa139f143fd0379d74577d93.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC1F5002V7/tesys-f-contactor-2p-2-no-ac1-440-v-700-a-coil-400-v-ac/"},"ai":{"faq":[{"question":"Where can I buy the LC1F5002V7?","answer":"The LC1F5002V7 is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position."},{"question":"What is the LC1F5002V7 rated for?","answer":"The LC1F5002V7 is rated for 700 A in AC-1 utilisation category (resistive loads) at up to 440 V AC, with a 400 V AC control coil. It is a 2-pole normally open contactor with a mechanical durability of 10 million cycles."},{"question":"What compliance documentation does Schneider provide for the LC1F5002V7?","answer":"The LC1F5002V7 is certified to IEC 60947-1, IEC 60947-4-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. The front face with shrouds carries IP20 protection per IEC 60529 and VDE 0106."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1F5002V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1F5002V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}