{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G1154LSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G1154LSEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G1154LSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G1154LSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G1154LSEN 4-pole contactor, 200-500 V AC/DC coil, AC-3/AC-3e/DC-1 utilisation, IP2X front face, dark grey.","salesMarkdown":"## Coil voltage range and what it saves you No need to stock separate coil variants for different panel voltages — a single LC1G1154LSEN handles it. ## What the utilisation categories tell a panel builder Rated for AC-3, AC-3e, AC-1, AC-5a/b, AC-6a/b, and DC-1/3/5. AC-3 is the standard motor-switching duty — the 115 A rating at 400 V handles pumps, fans, and compressors. AC-3e adds energy-efficiency motor starting. AC-1 covers resistive loads like heaters. The DC ratings let it switch DC motors or DC bus circuits without a separate DC-rated contactor. Mechanical durability is 8 Mcycles. At 600 cycles/hour AC-3, that's over 13,000 hours of continuous operation at full rated switching rate — built for high-cycle packaging or material-handling lines. ## Safety circuit integration and auxiliary contacts Built-in 1 NO + 1 NC auxiliary contact provides feedback to the PLC or safety relay without an add-on block. Safety reliability is quantified: B10d = 400,000 cycles at nominal load, 3,000,000 cycles with mechanical load per EN/ISO 13849-1. That lets you calculate the PFHd for your safety function without guessing. ## Wiring and panel fit Power terminals accept bar, busbar (25 x 6 mm cross-section), or ring lugs up to 185 mm². That's enough for the full rated current without parallel cables. Mounting is plate-mount with a 35 mm connection pitch. ## Standards and approvals — one part, multiple jurisdictions Also listed under UL 60335-1 and UL 60335-2-40 Annex JJ for appliance and HVAC applications. Overvoltage category III means it's rated for fixed-installation distribution panels, not just downstream equipment. Current production stage — no end-of-life notice.","metaTitle":"Schneider Electric LC1G1154LSEN TeSys Giga Contactor","metaDescription":"Schneider Electric LC1G1154LSEN TeSys Giga contactor. 4-pole, 200-500V AC/DC coil, AC-3 rated. UL/CSA/IEC. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"7.6 in (193 mm)","Range":"TeSys","Width":"5.6 in (143 mm)","title":"LC1G1154LSEN","Height":"7.6 in (193 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","description":"Contactor, high power, TeSys Giga, 4P(4NO), AC-1, <=440V 250A, standard version, 200-500V AC/DC wide band coil","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00018 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"159.3 lbf.in (18 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5","Contactor application":"Power switching","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"125 A aM at 125 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1","inrush power in W (DC)":"215 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1040 A at 440 V","Pole contact composition":"4 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1560 A at 440 V","Power dissipation per pole":"10 W AC-1 - Ith 250 A 3 W AC-3 - Ith 115 A","[Uc] control circuit voltage":"200...500 V AC 50/60 Hz 200...500 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"115 A (at 250 A (at <104 °F (40 °C)) at <= 1000 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"295 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"8 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.1 kA - 10 s 0.64 kA - 30 s 0.52 kA - 1 min 0.4 kA - 3 min 0.32 kA - 10 min","[Ith] conventional free air thermal current":"250 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$980.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc8b5019fcd670c91b91d4a9f4112db3.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G1154LSEN/contactor-high-power-tesys-giga-4p4no-ac1-440v-250a-standard-version-200500v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What compliance documentation does Schneider Electric provide for the LC1G1154LSEN?","answer":"Overvoltage category III. The protective treatment is TH (tropicalised). RoHS and REACH declarations are standard from Schneider for this series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G1154LSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G1154LSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}