{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G115XXEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G115XXEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G115XXEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G115XXEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga series, LC1G115XXEN, 3-pole contactor, 115 A, 55 kW at 400 V AC-3e, dark grey.","salesMarkdown":"The 30 kW rating at 230 V AC-3e covers lower-voltage installations, while the 75 kW rating at 690 V AC-3e suits higher-voltage European or mining distribution. Built-in bidirectional peak-limiting coil technology keeps inrush power at 230 W DC, which simplifies the control transformer sizing in a panel. The contactor is rated for 8 million mechanical cycles, so it outlasts many smaller-frame contactors in high-cycle applications like conveyor transfer stations or packaging lines. The motor power ratings span AC-3e, AC-3, and AC-4 duty classes. AC-3e is the energy-efficient motor standard (IEC 60947-4-1), covering modern IE3/IE4 motors with higher inrush. AC-4 covers plugging and inching — frequent reversing or jogging — where the contactor breaks full locked-rotor current. At 400 V AC-4, the rating drops to 55 kW, so if your application requires frequent reversing of a 55 kW motor, this contactor fits; for a 75 kW motor in AC-4, step up to the next frame. The rated breaking capacity is 1040 A at 440 V, and the rated making capacity is 1560 A at 440 V. These numbers govern the contactor's ability to close into and interrupt fault currents — important for coordination with upstream protection. The associated fuse ratings are 160 A aM (motor circuit) or 315 A gG (general-purpose) at 400 V, and 300 A UL Class J at 600 V. Match these to your short-circuit protection device for Type 2 coordination. Power dissipation per pole is 10 W at Ith 250 A in AC-1 (resistive) and 5 W at Ith 115 A in AC-3 (motor). Mounts to a plate (not DIN rail — the TeSys Giga frame uses bolted mounting). The 35 mm connection pitch and bar/busbar terminals (accepting up to 25 x 6 mm busbar or 185 mm² ring lugs) are sized for the 115 A continuous rating. Tightening torque on the power terminals is 18 N·m. The contactor carries 1 NO + 1 NC built-in auxiliary contact. For additional signalling or interlocking, add a side-mount auxiliary block from the TeSys Giga range. The IP2X front-face protection (with shrouds) meets IEC 60529 and VDE 0106 for finger-safe installation inside a locked enclosure. Designed and certified to EN/IEC 60947-4-1 (contactors and motor-starters), EN/IEC 60947-5-1 (control-circuit devices), UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1 / C8201-5-1. Protective treatment TH (tropicalised) for humid environments.","metaTitle":"Schneider Electric LC1G115XXEN TeSys Giga Contactor, 115 A,","metaDescription":"Schneider Electric LC1G115XXEN TeSys Giga 3-pole contactor. Rated 115 A, 55 kW at 400 V AC-3e. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"7.6 in (193 mm)","Range":"TeSys","Width":"4.3 in (108 mm)","title":"LC1G115XXEN","Height":"7.6 in (193 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1","description":"High power contactor,TeSys Giga,3P(3NO),AC-3 <=440V 115A,standard version,600V AC/DC coil","Motor power kW":"30 kW at 230 V AC 50/60 Hz (AC-3e) 55 kW at 400 V AC 50/60 Hz (AC-3e) 55 kW at 415 V AC 50/60 Hz (AC-3e) 75 kW at 440 V AC 50/60 Hz (AC-3e) 75 kW at 500 V AC 50/60 Hz (AC-3e) 75 kW at 690 V AC 50/60 Hz (AC-3e) 30 kW at 230 V AC 50/60 Hz (AC-3) 55 kW at 400 V AC 50/60 Hz (AC-3) 55 kW at 415 V AC 50/60 Hz (AC-3) 75 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 75 kW at 690 V AC 50/60 Hz (AC-3) 30 kW at 230 V AC 50/60 Hz (AC-4) 55 kW at 400 V AC 50/60 Hz (AC-4) 55 kW at 415 V AC 50/60 Hz (AC-4) 65 kW at 440 V AC 50/60 Hz (AC-4) 65 kW at 500 V AC 50/60 Hz (AC-4) 75 kW at 690 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00018 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"159.3 lbf.in (18 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"160 A aM at 160 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"230 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1040 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1560 A at 440 V","Maximum Horse Power Rating":"30 hp at 200/208 V 60 Hz 40 hp at 230/240 V 60 Hz 75 hp at 460/480 V 60 Hz 100 hp at 575/600 V 60 Hz","Power dissipation per pole":"10 W AC-1 - Ith 250 A 5 W AC-3 - Ith 115 A","[Uc] control circuit voltage":"600 V AC 50/60 Hz 600 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"250 A (at 115 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"350 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"8 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.2 kA - 10 s 0.7 kA - 30 s 0.6 kA - 1 min 0.45 kA - 3 min 0.35 kA - 10 min","[Ith] conventional free air thermal current":"250 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$715.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/54d71f3b9bf0c5805bd21b0407b14358.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G115XXEN/high-power-contactortesys-giga3p3noac3-440v-115astandard-version600v-ac-dc-coil/"},"ai":{"faq":[{"question":"What motor power does this contactor handle at 400 V?","answer":"It is rated for 55 kW at 400 V AC in AC-3e (energy-efficient motor) and AC-3 duty, and 55 kW in AC-4 (frequent reversing)."},{"question":"What are the auxiliary contact options?","answer":"The contactor comes with 1 NO + 1 NC built-in auxiliary contacts. Additional auxiliary contact blocks can be side-mounted."},{"question":"What standards does this contactor comply with?","answer":"It complies with EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1 / C8201-5-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G115XXEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G115XXEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}