{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G1504EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G1504EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G1504EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G1504EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga, LC1G1504EHES207N, 4-pole contactor, 75 kW at 400 V AC-3e, coil 48-130 V AC/DC, plate mount.","salesMarkdown":"Its AC-3e rating of 75 kW at 400 V AC 50/60 Hz means it switches three-phase induction motors up to that load without welding the main contacts — the 'e' suffix indicates enhanced electrical durability for frequent starting. At 460/480 V 60 Hz it handles 100 hp, and at 575/600 V 60 Hz it handles 125 hp, making it a fit for North American motor frames as well. The utilisation category list covers AC-1 (resistive), AC-3/AC-3e (squirrel-cage motors), AC-4 (plugging/inching), and DC-1/DC-3/DC-5 — so this contactor is not limited to motor starting; it handles resistive heating banks, DC loads, and mixed-duty panels. The 8 Mcycles mechanical durability means the actuator and spring set outlast the electrical contacts under normal switching; you replace the contact kit, not the whole device, at end of electrical life. Coil technology uses built-in bidirectional peak limiting, which suppresses voltage spikes on the control circuit — no external varistor or RC snubber needed across the coil terminals. The control circuit voltage range of 48...130 V AC 50/60 Hz and 48...130 V DC covers common control voltages in both IEC and NEMA panels, but the drop-out threshold of 0.1 Uc to 0.45 Uc at <60 °C means it releases reliably on a sagging control supply. Plate-mounted (not DIN-rail), so it goes on a backplate or sub-panel with bolted connections. The power circuit accepts bar or busbar up to 25 x 6 mm, or lugs up to 185 mm² — sized for the 150 A frame. The 193 mm cube footprint (193 x 105 x 193 mm) is compact for a 4-pole contactor at this rating; plan for a 35 mm connection pitch between phases. Certified to EN/IEC 60947-4-1 and 60947-5-1 (the core contactor and control-circuit standards), plus UL 60947-4-1 and CSA C22.2 No 60947-4-1 for North American acceptance. Also listed under UL 60335-1 and UL 60335-2-40 Annex JJ for household and HVAC equipment — relevant if this contactor lands in a packaged unit. The protective treatment 'TH' means it is tropicalised for humid environments.","metaTitle":"TeSys Giga LC1G1504EHES207N Contactor, 75 kW at 400 V AC-3e","metaDescription":"Schneider Electric TeSys Giga LC1G1504EHES207N 4-pole contactor. 75 kW at 400 V AC-3e, 100 hp at 460 V. Coil 48-130 V AC/DC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"193 mm","Range":"TeSys","Width":"105 mm","Colour":"Dark grey","Height":"193 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","Motor power hp":"40 hp at 200/208 V 60 Hz 50 hp at 230/240 V 60 Hz 100 hp at 460/480 V 60 Hz 125 hp at 575/600 V 60 Hz","Motor power kW":"37 kW at 230 V AC 50/60 Hz (AC-3e) 75 kW at 400 V AC 50/60 Hz (AC-3e) 75 kW at 415 V AC 50/60 Hz (AC-3e) 90 kW at 440 V AC 50/60 Hz (AC-3e) 90 kW at 500 V AC 50/60 Hz (AC-3e) 90 kW at 690 V AC 50/60 Hz (AC-3e) 75 kW at 1000 V AC 50/60 Hz (AC-3e) 37 kW at 230 V AC 50/60 Hz (AC-3) 75 kW at 400 V AC 50/60 Hz (AC-3) 75 kW at 415 V AC 50/60 Hz (AC-3) 90 kW at 440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 90 kW at 690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 37 kW at 230 V AC 50/60 Hz (AC-4) 75 kW at 400 V AC 50/60 Hz (AC-4) 75 kW at 415 V AC 50/60 Hz (AC-4) 80 kW at 440 V AC 50/60 Hz (AC-4) 90 kW at 500 V AC 50/60 Hz (AC-4) 90 kW at 690 V AC 50/60 Hz (AC-4) 75 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.00018 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"18 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"160 A aM at 160 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"300 cyc/h AC-1 500 cyc/h AC-3 500 cyc/h AC-3e 150 cyc/h AC-4","inrush power in W (DC)":"445 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1280 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"1890 A at 440 V","Power dissipation per pole":"10 W AC-1 - Ith 275 A 5 W AC-3 - Ith 150 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"275 A (at 150 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"640 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"7.8 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.2 kA - 10 s 0.7 kA - 30 s 0.6 kA - 1 min 0.45 kA - 3 min 0.35 kA - 10 min","[Ith] conventional free air thermal current":"275 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/176f75816be5305f2b6468b9138b0d26.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1G1504EHES207N/high-power-contactortesys-giga-s2074p4noac3-440v-150astandard-version48130v-ac-dc-wide-band-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G1504EHES207N/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for LC1G1504EHES207N?","answer":"The contactor is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, UL 60335-1, and UL 60335-2-40 Annex JJ. Protective treatment is TH (tropicalised)."},{"question":"What is the closest pin-compatible alternative in the TeSys Giga family?","answer":"Within the TeSys Giga range, the closest peer is the LC1G1504... variant with a different coil voltage. The mechanical footprint, pole configuration, and power-circuit connections are identical across the 150 A frame; only the control circuit voltage and coil technology change. Verify the coil code matches your control voltage before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G1504EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G1504EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}