{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G1504LSEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G1504LSEA","canonicalUrl":"https://aoctrl.com/schneider/LC1G1504LSEA","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G1504LSEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G1504LSEA 4-pole contactor, 150 A AC-3, coil 200-500 V AC/DC, mechanically durable 8 Mcycles.","salesMarkdown":"## Integration brief – LC1G1504LSEA 4-pole TeSys Giga contactor in the LC1G family, set up for power switching of motor loads up to 150 A in AC-3 duty. Built-in bidirectional peak limiting on the coil suppresses switching transients – no external surge suppressor needed on the control circuit. Rated breaking capacity 1280 A at 440 V and making capacity 1890 A – numbers that confirm the contactor can handle inrush and fault clearing within the panel's protection coordination. Mechanical durability rated to 8 million cycles; for safety-rated applications the B10d is 400,000 cycles at nominal load per EN/ISO 13849-1. ## Lifecycle & compliance status Standards coverage includes EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, plus UL 60335 household appliance references. That's a single part that satisfies IEC, UL, and CSA panel builds without variant splits. ## Mounting & wiring notes Plate mount only – no DIN rail option. 4-hole pattern with 35 mm connection pitch on the power terminals; busbars sized for 25 x 6 mm cross-section or ring terminals up to 185 mm². Tightening torque on power connections is 18 N.m – tool selection matters for consistent clamping. IP2X with shrouds on the front face, so finger-safe termination if covers are fitted. Operating time: closing 40-70 ms, opening 15-50 ms – falls within typical contactor response for coordinated starter setups. Maximum electrical operating rate 600 cycles/h for AC-3, 300 cycles/h for AC-1. ## Sourcing & order recommendation Active, current-production part. No escalation needed for supply – confirm the BOM line and we can place an order against your RFQ. The 4-pole format with 1 NO + 1 NC auxiliary block built in covers most interlocking and feedback requirements; no auxiliary kit required for basic status. If the panel operates near 40°C ambient, note the rated current table: 150 A AC-3 at <= 440 V, but the AC-1 current is 275 A at <40°C – observe derating if the panel runs hot. The power dissipation per pole is 10 W in AC-1 at 275 A and 5 W in AC-3 at 150 A, so enclosure heat load is predictable.","metaTitle":"Schneider LC1G1504LSEA Contactor, 150A AC-3, 200-500V","metaDescription":"Current production TeSys Giga 4-pole contactor. 150 A AC-3 rated operational current, 200-500 V AC/DC coil. 8 Mcycles mechanical durability. Complies with UL, CSA, IEC, JIS. RFQ fo","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"193 mm","Range":"TeSys","Width":"143 mm","Colour":"Dark grey","Height":"255 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","Operating time":"40...70 ms closing 15...50 ms opening","Product weight":"5.1 kg","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.00018 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"18 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5","Contactor application":"Power switching","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"160 A aM at 160 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1","inrush power in W (DC)":"215 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"1280 A at 440 V","Pole contact composition":"4 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"1890 A at 440 V","Power dissipation per pole":"10 W AC-1 - Ith 275 A 5 W AC-3 - Ith 150 A","[Uc] control circuit voltage":"200...500 V AC 50/60 Hz 200...500 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"150 A (at 275 A (at <40 °C) at <= 1000 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"295 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"8.0 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.2 kA - 10 s 0.7 kA - 30 s 0.6 kA - 1 min 0.45 kA - 3 min 0.35 kA - 10 min","[Ith] conventional free air thermal current":"275 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,353.10","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/176f75816be5305f2b6468b9138b0d26.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G1504LSEA/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the LC1G1504LSEA?","answer":"The listed depth is 193 mm. Combined with a width of 143 mm and height of 255 mm, the footprint fits standard TeSys Giga panel layouts."},{"question":"What range is the LC1G1504LSEA from?","answer":"It belongs to the TeSys Giga range (TeSys family). The series code is LC1G."},{"question":"What compliance documentation does the LC1G1504LSEA carry?","answer":"The contactor is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and UL 60335-1/60335-2-40. Protective treatment TH (tropical) is also applied. RoHS and REACH declarations are typically included with shipments but are not specified in the core listing; request through the RFQ if needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G1504LSEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G1504LSEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}