{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G150BEEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G150BEEA","canonicalUrl":"https://aoctrl.com/schneider/LC1G150BEEA","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G150BEEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga contactor, 3P, LC1G150BEEA, 24-48 V AC/DC coil, motor power 75 kW at 400 V AC-3e.","salesMarkdown":"## Contactor role and key ratings The Schneider LC1G150BEEA is a 3-pole TeSys Giga contactor rated for motor switching in AC-3e duty at 75 kW on a 400 V line, with a 24–48 V AC/DC coil. Built-in bidirectional peak limiting holds the coil inrush to 220 W DC, and the drop-out range (15–50 ms opening) avoids nuisance chatter during dips. Mechanical durability is 8 million cycles; the contactor can cycle 600 times per hour in AC-3 and AC-3e, 150 per hour in AC-4. That tells you it can handle high-rate motor starts without wearing out early. ## Where and how it fits Mounts on a plate (not rail). Power terminals accept bars (25x6 mm) or ring lugs up to 185 mm²; control circuit uses push-in terminals for 0.2–2.5 mm² stranded or solid. Tightening torque for power connections is 18 N·m. Front face with shrouds gives IP2X protection (IEC 60529). The TH protective treatment (tropicalization) handles humid environments. Associated fuse recommendation: 160 A aM or 315 A gG for short-circuit coordination. ## Compliance and sourcing posture Lifecycle stage is current — no end-of-life notice. It carries UL 60947-4-1, CSA, IEC, and JIS certifications, qualifying it for panels in North America, Europe, and Japan. Sourced to order against RFQ. This is an active catalog part; lead time and pricing depend on your volume and preferred region. Submit an RFQ to lock a line for your BOM.","metaTitle":"Schneider Electric LC1G150BEEA TeSys Giga, 3P 24-48V","metaDescription":"TeSys Giga contactor LC1G150BEEA, 3P, 24-48V coil, 75 kW@400V AC-3e, in production, UL/IEC. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"7.6 in (193 mm)","Range":"TeSys","Width":"4.3 in (108 mm)","Height":"10.04 in (255 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","Motor power kW":"37 kW at 230 V AC 50/60 Hz (AC-3e) 75 kW at 400 V AC 50/60 Hz (AC-3e) 75 kW at 415 V AC 50/60 Hz (AC-3e) 90 kW at 440 V AC 50/60 Hz (AC-3e) 90 kW at 500 V AC 50/60 Hz (AC-3e) 90 kW at 690 V AC 50/60 Hz (AC-3e) 75 kW at 1000 V AC 50/60 Hz (AC-3e) 37 kW at 230 V AC 50/60 Hz (AC-3) 75 kW at 400 V AC 50/60 Hz (AC-3) 75 kW at 415 V AC 50/60 Hz (AC-3) 90 kW at 440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 90 kW at 690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 37 kW at 230 V AC 50/60 Hz (AC-4) 75 kW at 400 V AC 50/60 Hz (AC-4) 75 kW at 415 V AC 50/60 Hz (AC-4) 80 kW at 440 V AC 50/60 Hz (AC-4) 90 kW at 500 V AC 50/60 Hz (AC-4) 90 kW at 690 V AC 50/60 Hz (AC-4) 75 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00018 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"159.3 lbf.in (18 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"160 A aM at 160 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"220 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1280 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1890 A at 440 V","Maximum Horse Power Rating":"40 hp at 200/208 V 60 Hz 50 hp at 230/240 V 60 Hz 100 hp at 460/480 V 60 Hz 125 hp at 575/600 V 60 Hz","Power dissipation per pole":"10 W AC-1 - Ith 275 A 5 W AC-3 - Ith 150 A","[Uc] control circuit voltage":"24...48 V AC 50/60 Hz 24...48 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"275 A (at 150 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"290 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"5.7 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.2 kA - 10 s 0.7 kA - 30 s 0.6 kA - 1 min 0.45 kA - 3 min 0.35 kA - 10 min","[Ith] conventional free air thermal current":"275 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,013.09","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/176f75816be5305f2b6468b9138b0d26.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G150BEEA/alternatives.json"},"ai":{"faq":[{"question":"What is the listed color of the LC1G150BEEA?","answer":"Dark grey."},{"question":"What is the depth of this contactor?","answer":"7.6 in (193 mm)."},{"question":"What compliance documentation does this contactor meet?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2, JIS C8201, and related standards. The front face achieves IP2X with shrouds."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G150BEEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G150BEEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}