{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G185BEEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G185BEEA","canonicalUrl":"https://aoctrl.com/schneider/LC1G185BEEA","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G185BEEA","rawCanonicalId":null},"summary":{"shortDescription":"TeSys Giga 3-pole contactor, LC1G185BEEA, motor power 90 kW at 400 V AC-3e, control 24-48 V AC/DC, built-in peak limiting coil.","salesMarkdown":"The LC1G185BEEA is a 3-pole contactor from the TeSys Giga range, rated for motor power up to 90 kW at 400 V AC in AC-3e duty. Control coil accepts 24-48 V AC or DC with built-in bidirectional peak limiting, so no external suppression network is needed on this terminal set. ## Mounting & connection data Mounts on a plate using the four fixing holes with a connection pitch of 1.4 in (35 mm). Power terminals accept bar (25 x 6 mm cross-section) or lug ring terminals up to 185 mm²; control wiring is push-in type accepting 0.2…2.5 mm² solid or stranded with ferrule. Tightening torque for power connections is 159.3 lbf·in (18 N·m). Overall dimensions: depth 7.6 in (193 mm), width 4.3 in (108 mm), height 10.04 in (255 mm). ## Auxiliary contacts & operating characteristics The contactor ships with one normally-open and one normally-closed auxiliary contact (1 NO + 1 NC), sufficient for basic feedback. Closing time is 40…70 ms, opening 15…50 ms. Mechanical durability is rated at 8 million cycles. For thermal dissipation, expect 20 W per pole at full rated thermal current (305 A AC-1) and 6 W per pole under typical AC-3 load (185 A).","metaTitle":"LC1G185BEEA TeSys Giga Contactor, 3-Pole, 24-48V AC/DC Coil","metaDescription":"Active-production 3-pole contactor from TeSys Giga range. Rated 90 kW at 400 V AC-3e, control circuit 24-48 V AC/DC. UL, CSA, IEC 60947-4-1 compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"7.6 in (193 mm)","Range":"TeSys","Width":"4.3 in (108 mm)","Height":"10.04 in (255 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","Motor power kW":"55 kW at 230 V AC 50/60 Hz (AC-3e) 90 kW at 400 V AC 50/60 Hz (AC-3e) 90 kW at 415 V AC 50/60 Hz (AC-3e) 110 kW at 440 V AC 50/60 Hz (AC-3e) 110 kW at 500 V AC 50/60 Hz (AC-3e) 110 kW at 690 V AC 50/60 Hz (AC-3e) 75 kW at 1000 V AC 50/60 Hz (AC-3e) 55 kW at 230 V AC 50/60 Hz (AC-3) 90 kW at 400 V AC 50/60 Hz (AC-3) 90 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 110 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 230 V AC 50/60 Hz (AC-4) 90 kW at 400 V AC 50/60 Hz (AC-4) 90 kW at 415 V AC 50/60 Hz (AC-4) 100 kW at 440 V AC 50/60 Hz (AC-4) 110 kW at 500 V AC 50/60 Hz (AC-4) 110 kW at 690 V AC 50/60 Hz (AC-4) 75 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00017 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"159.3 lbf.in (18 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A aM at 160 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"220 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1610 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"2310 A at 440 V","Maximum Horse Power Rating":"50 hp at 200/208 V 60 Hz 60 hp at 230/240 V 60 Hz 125 hp at 460/480 V 60 Hz 150 hp at 575/600 V 60 Hz","Power dissipation per pole":"20 W AC-1 - Ith 305 A 6 W AC-3 - Ith 185 A","[Uc] control circuit voltage":"24...48 V AC 50/60 Hz 24...48 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"305 A (at 185 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"290 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"5.7 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.5 kA - 10 s 0.92 kA - 30 s 0.74 kA - 1 min 0.5 kA - 3 min 0.4 kA - 10 min","[Ith] conventional free air thermal current":"305 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,179.95","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/95632ca7a5e84c7924b3d132d994a0d9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G185BEEA/alternatives.json"},"ai":{"faq":[{"question":"What color is the LC1G185BEEA?","answer":"It is dark grey per the manufacturer listing."},{"question":"What is the depth of the LC1G185BEEA?","answer":"7.6 in (193 mm)."},{"question":"What compliance documentation does this contactor carry?","answer":"It is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and JIS C8201-5-1, among those listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G185BEEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G185BEEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}