{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G185XXEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G185XXEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G185XXEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G185XXEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G185XXEN, 3-pole contactor, AC-3e 90 kW at 400 V, built-in bidirectional peak limiting coil, IP2X front face.","salesMarkdown":"The Schneider Electric TeSys Giga LC1G185XXEN is a 3-pole contactor (3 NO main poles, 1 NO + 1 NC auxiliary) rated for power switching and motor control in utilisation categories including AC-1, AC-3, AC-3e, AC-4, and DC-1 through DC-5. It mounts on a plate with bolted power connections and push-in control wiring. The headline motor power rating is 90 kW at 400 V AC 50/60 Hz under AC-3e duty, which is the standard for squirrel-cage motor starting — that covers a 125 hp motor at 460/480 V 60 Hz on the horsepower side. For heavier duty like plugging or inching (AC-4), it still carries 90 kW at 400 V, so it's not derated for reversing applications. The built-in bidirectional peak limiting coil technology means you don't need external varistors or RC snubbers for coil suppression — it handles the inductive kick internally, which saves panel space and one wiring step. The coil holds across 600 V AC or DC control circuits, so it works on both common control voltages without a separate power supply. The maximum operating rate is 600 cycles/hour for AC-3 and AC-3e, and 150 cycles/hour for AC-4, so match your duty cycle to the utilisation category. The IP2X front face protection (with shrouds) means the live terminals are finger-safe once shrouded — standard for open panel mounting where accidental contact is a concern. The TH protective treatment adds humidity resistance for non-condensing environments. This contactor class is the workhorse for motor control centres, pump panels, compressor starters, and conveyor drives in industrial and commercial buildings. The 3-pole configuration handles three-phase motors up to 110 kW at 690 V AC-3, so it covers most medium-voltage motor applications up to 600 V class. The plate-mount design and bolted power connections (up to 185 mm² lugs) mean it's intended for fixed installation in a panel, not DIN-rail snap-on — plan for drilling and torquing to 18 N·m on the power terminals. It carries approvals to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, so it's accepted in North American, European, and Japanese installations. The B10d values (400,000 cycles at nominal load, 3,000,000 cycles at mechanical load per EN/ISO 13849-1) support safety circuit integration where contactor reliability is part of the safety function.","metaTitle":"Schneider Electric TeSys Giga LC1G185XXEN Contactor, 3P, 90","metaDescription":"TeSys Giga LC1G185XXEN 3-pole contactor, 90 kW at 400 V AC-3, 8 Mcycles mechanical durability, built-in peak limiting coil. Current lifecycle stage. UL/CSA/IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"7.6 in (193 mm)","Range":"TeSys","Width":"4.3 in (108 mm)","title":"LC1G185XXEN","Height":"7.6 in (193 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1","description":"High power contactor,TeSys Giga,3P(3NO),AC-3 <=440V 185A,standard version,600V AC/DC coil","Motor power kW":"55 kW at 230 V AC 50/60 Hz (AC-3e) 90 kW at 400 V AC 50/60 Hz (AC-3e) 90 kW at 415 V AC 50/60 Hz (AC-3e) 110 kW at 440 V AC 50/60 Hz (AC-3e) 110 kW at 500 V AC 50/60 Hz (AC-3e) 110 kW at 690 V AC 50/60 Hz (AC-3e) 75 kW at 1000 V AC 50/60 Hz (AC-3e) 55 kW at 230 V AC 50/60 Hz (AC-3) 90 kW at 400 V AC 50/60 Hz (AC-3) 90 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 110 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 690 V AC 50/60 Hz (AC-3) 75 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 230 V AC 50/60 Hz (AC-4) 90 kW at 400 V AC 50/60 Hz (AC-4) 90 kW at 415 V AC 50/60 Hz (AC-4) 100 kW at 440 V AC 50/60 Hz (AC-4) 110 kW at 500 V AC 50/60 Hz (AC-4) 110 kW at 690 V AC 50/60 Hz (AC-4) 75 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00017 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"159.3 lbf.in (18 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A aM at 160 A aM at 315 A gG at 300 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"230 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"1610 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"2310 A at 440 V","Maximum Horse Power Rating":"50 hp at 200/208 V 60 Hz 60 hp at 230/240 V 60 Hz 125 hp at 460/480 V 60 Hz 150 hp at 575/600 V 60 Hz","Power dissipation per pole":"20 W AC-1 - Ith 305 A 6 W AC-3 - Ith 185 A","[Uc] control circuit voltage":"600 V AC 50/60 Hz 600 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"305 A (at 185 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"350 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"8 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.5 kA - 10 s 0.92 kA - 30 s 0.74 kA - 1 min 0.5 kA - 3 min 0.4 kA - 10 min","[Ith] conventional free air thermal current":"305 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$935.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/23f74a2810abf83900f4f3905fd74051.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G185XXEN/high-power-contactortesys-giga3p3noac3-440v-185astandard-version600v-ac-dc-coil/"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for LC1G185XXEN?","answer":"The contactor is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Safety reliability data per EN/ISO 13849-1 is also available (B10d values)."},{"question":"What is LC1G185XXEN's listed colour?","answer":"The colour is dark grey."},{"question":"What is LC1G185XXEN's listed depth?","answer":"The depth is 7.6 inches (193 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G185XXEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G185XXEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}