{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G2254EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G2254EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G2254EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G2254EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G2254EHES207N, 4-pole contactor, 110 kW at 400 V AC-3e, 48-130 V AC/DC coil, plate mount.","salesMarkdown":"The Schneider Electric LC1G2254EHES207N is a 4-pole power contactor from the TeSys Giga range, rated for motor control and power switching across AC-1 through AC-6b and DC-1 through DC-5 utilisation categories. Its headline motor rating is 110 kW at 400 V AC-3e, with the same figure at 415 V and stepping up to 160 kW at 690 V AC-3e. The control circuit accepts 48 to 130 V AC or DC, with built-in bidirectional peak limiting on the coil. That coil technology means you don't need external suppression on the control side — the contactor handles its own inrush (445 W peak) and holds in with low dissipation. At 400 V, 110 kW translates to roughly 225 A continuous in AC-3e duty, and the contactor's power dissipation per pole is 8 W at that current. The mechanical durability of 8 million cycles is high for this frame size, and the maximum operating rate of 500 cycles per hour in AC-3e matches a fast cycling conveyor or pump station. The 4-pole configuration (3 NO main poles + 1 NO + 1 NC auxiliary built in) gives you the third pole for a star-delta transition or for switching a second load, and the auxiliary set covers feedback to the PLC without an add-on block. This contactor mounts to a plate, not a DIN rail — the 105 mm width and 193 mm depth mean it takes up a dedicated footprint in the enclosure. The power connections are bolted: bar or busbar up to 25 x 6 mm, or ring lugs up to 185 mm². The tightening torque on the main terminals is 18 N·m, so a torque wrench is part of the install. The front face with shrouds gives IP2X finger protection per IEC 60529. The protective treatment (TH) means it's coated for tropical humidity — relevant if the panel sits in an unconditioned space.","metaTitle":"TeSys Giga LC1G2254EHES207N Contactor, 4P, 110 kW at 400 V A","metaDescription":"TeSys Giga LC1G2254EHES207N 4-pole contactor. 110 kW at 400 V AC-3e, 48-130 V AC/DC coil. UL/CSA/IEC listed. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"193 mm","Range":"TeSys","Width":"105 mm","title":"LC1G2254EHES207N","Colour":"Dark grey","Height":"193 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","description":"High power contactor,TeSys Giga S207,4P(4NO),AC-3 <=440V 225A,standard version,48-130V AC/DC wide band coil","Motor power hp":"60 hp at 200/208 V 60 Hz 75 hp at 230/240 V 60 Hz 150 hp at 460/480 V 60 Hz 150 hp at 575/600 V 60 Hz","Motor power kW":"55 kW at 230 V AC 50/60 Hz (AC-3e) 110 kW at 400 V AC 50/60 Hz (AC-3e) 110 kW at 415 V AC 50/60 Hz (AC-3e) 132 kW at 440 V AC 50/60 Hz (AC-3e) 132 kW at 500 V AC 50/60 Hz (AC-3e) 160 kW at 690 V AC 50/60 Hz (AC-3e) 132 kW at 1000 V AC 50/60 Hz (AC-3e) 55 kW at 230 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 132 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 690 V AC 50/60 Hz (AC-3) 132 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 230 V AC 50/60 Hz (AC-4) 110 kW at 400 V AC 50/60 Hz (AC-4) 110 kW at 415 V AC 50/60 Hz (AC-4) 129 kW at 440 V AC 50/60 Hz (AC-4) 132 kW at 500 V AC 50/60 Hz (AC-4) 132 kW at 690 V AC 50/60 Hz (AC-4) 110 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.00015 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"18 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"250 A aM at 200 A aM at 400 A gG at 400 A UL Type J at <= 600 V","Maximum operating rate":"300 cyc/h AC-1 500 cyc/h AC-3 500 cyc/h AC-3e 150 cyc/h AC-4","inrush power in W (DC)":"445 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"2050 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"2720 A at 440 V","Power dissipation per pole":"20 W AC-1 - Ith 330 A 8 W AC-3 - Ith 225 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"330 A (at 225 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"640 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"7.8 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.8 kA - 10 s 1.0 kA - 30 s 0.85 kA - 1 min 0.56 kA - 3 min 0.44 kA - 10 min","[Ith] conventional free air thermal current":"330 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/46ac3abe631ae2c273ef50f0c970a124.pdf","sourceUrl":"https://www.se.com/za/en/product/LC1G2254EHES207N/high-power-contactortesys-giga-s2074p4noac3-440v-225astandard-version48130v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for LC1G2254EHES207N?","answer":"The contactor is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, UL 60335-1, and UL 60335-2-40 Annex JJ. These cover the main power switching and control circuit standards for industrial and appliance applications."},{"question":"What is the closest alternative to LC1G2254EHES207N in the TeSys Giga family?","answer":"Within the TeSys Giga range, the closest peer is a 4-pole contactor with the same frame size but a different coil voltage. The LC1G2254EHES207N uses a 48-130 V AC/DC coil; a variant with a 24 V DC or 220-240 V AC coil would be the same physical fit and same power ratings, differing only in control voltage. No pin-compatible alternative exists outside the TeSys Giga platform — the mounting plate, busbar connections, and push-in control terminals are specific to this series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G2254EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G2254EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}