{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G225EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G225EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G225EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G225EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga series, LC1G225EHES207N, 3-pole contactor, 110 kW at 400 V AC-3e, 48-130 V AC/DC coil, plate mount.","salesMarkdown":"The Schneider Electric LC1G225EHES207N is a 3-pole TeSys Giga contactor rated for motor switching at 110 kW on a 400 V AC three-phase supply under AC-3e duty. That rating covers the most common European and Asian industrial motor voltages — 400 V and 415 V — so it fits directly into a standard 400 V class panel without derating. The 48-130 V AC/DC control coil gives you flexibility across control schemes: it accepts nominal 48 V, 110 V, or 120 V control circuits without needing a separate coil change. Built-in bidirectional peak limiting on the coil means you don't need an external varistor or RC snubber for most installations. The coil holds in at 0.8 Uc minimum and drops out between 0.1 and 0.45 Uc, which is a standard dropout margin for noisy industrial environments. This is a plate-mount contactor — not DIN-rail snap-on. The 35 mm connection pitch and bolted power terminals (accepting up to 185 mm² lugs or 25 x 6 mm busbars) tell you this is sized for a motor control center or a dedicated backplate, not a crowded DIN rail. Dimensions are 193 mm deep, 108 mm wide, and 193 mm tall. The IP2X front face with shrouds meets touch-safe requirements per IEC 60529 and VDE 0106, so it can sit in a panel with the front exposed during maintenance. The TeSys Giga family is Schneider's current-generation heavy-duty contactor platform, so replacement parts and accessories (auxiliary contact blocks, surge suppressors, mechanical interlocks) are all active and available. The same contactor also carries AC-4 ratings (110 kW at 400 V), which covers plugging and inching duty where the motor is reversed or stopped electrically. That's a high-duty-cycle machine rate — think conveyor sortation or pump cycling, not a once-a-shift start. The B10d safety reliability figure of 400,000 cycles under nominal load (per EN/ISO 13849-1) means it can be used in safety-related control circuits up to that lifetime. Power dissipation per pole is 20 W at AC-1 (330 A thermal current) and 8 W at AC-3 (225 A). That's useful for thermal coordination in a sealed enclosure — you can calculate the cabinet heat load directly from these figures.","metaTitle":"Schneider Electric LC1G225EHES207N TeSys Giga Contactor, 110","metaDescription":"Schneider Electric LC1G225EHES207N TeSys Giga contactor. 3-pole, 110 kW at 400 V AC-3e. 48-130 V AC/DC coil. UL, CSA, IEC certified. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"193 mm","Range":"TeSys","Width":"108 mm","Colour":"Dark grey","Height":"193 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","Motor power hp":"60 hp at 200/208 V 60 Hz 75 hp at 230/240 V 60 Hz 150 hp at 460/480 V 60 Hz 150 hp at 575/600 V 60 Hz","Motor power kW":"55 kW at 230 V AC 50/60 Hz (AC-3e) 110 kW at 400 V AC 50/60 Hz (AC-3e) 110 kW at 415 V AC 50/60 Hz (AC-3e) 132 kW at 440 V AC 50/60 Hz (AC-3e) 132 kW at 500 V AC 50/60 Hz (AC-3e) 160 kW at 690 V AC 50/60 Hz (AC-3e) 132 kW at 1000 V AC 50/60 Hz (AC-3e) 55 kW at 230 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 132 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 690 V AC 50/60 Hz (AC-3) 132 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 230 V AC 50/60 Hz (AC-4) 110 kW at 400 V AC 50/60 Hz (AC-4) 110 kW at 415 V AC 50/60 Hz (AC-4) 129 kW at 440 V AC 50/60 Hz (AC-4) 132 kW at 500 V AC 50/60 Hz (AC-4) 132 kW at 690 V AC 50/60 Hz (AC-4) 110 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"35 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.00015 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"18 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"250 A aM at 200 A aM at 400 A gG at 400 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"445 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"2050 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"2720 A at 440 V","Power dissipation per pole":"20 W AC-1 - Ith 330 A 8 W AC-3 - Ith 225 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"330 A (at 225 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"640 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"7.8 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.8 kA - 10 s 1.0 kA - 30 s 0.85 kA - 1 min 0.56 kA - 3 min 0.44 kA - 10 min","[Ith] conventional free air thermal current":"330 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f663fb7966b9e5050589fab48c642ea7.pdf","sourceUrl":"https://www.se.com/be/en/product/LC1G225EHES207N/high-power-contactortesys-giga-s2073p3noac3-440v-225astandard-version48130v-ac-dc-wide-band-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G225EHES207N/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this contactor?","answer":"The LC1G225EHES207N carries EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, IEC 60335-1 Clause 30.2, IEC 60335-2-40 Annex JJ, UL 60335-1, and UL 60335-2-40 Annex JJ certifications. RoHS and REACH declarations are standard with the factory documentation package."},{"question":"What is the control voltage range for this contactor?","answer":"The coil accepts 48-130 V AC at 50/60 Hz and 48-130 V DC. The operational limits are 0.8 Uc minimum to 1.1 Uc maximum, with dropout between 0.1 and 0.45 Uc at temperatures below 60 °C."},{"question":"What are the physical dimensions of the LC1G225EHES207N?","answer":"The contactor measures 193 mm deep, 108 mm wide, and 193 mm tall. It is plate-mounted with a 35 mm connection pitch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G225EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G225EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}