{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G225KUEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G225KUEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G225KUEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G225KUEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga, Contactor, 3P, LC1G225KUEN, 110 kW at 400 V AC-3e, coil 100-250 V AC/DC, 8 Mcycles mechanical durability.","salesMarkdown":"It switches 110 kW at 400 V AC-3e (motor duty) and covers up to 160 kW at 690 V in the same category. The coil is 100-250 V AC/DC with built-in bidirectional peak limiting — no external suppressor needed on the control circuit. AC-3e is the motor-switching category with improved lifetime for modern energy-efficient motors. At 400 V, that 110 kW rating is the number you care about for a typical 400 V three-phase line. AC-1 resistive rating is higher (330 A thermally) but for motor loads AC-3 and AC-3e govern. The utilisation list also covers AC-4 (plugging/reversing) and DC loads, so this contactor handles mixed duty. Mechanical durability: 8 Mcycles. Operating rate: 600 cyc/h AC-3, 150 cyc/h AC-4. Average impedance: 0.00015 Ohm per pole; dissipation: 20 W per pole at 330 A AC-1. ## Integration notes Mounts on a plate (not DIN rail) — the 35 mm connection pitch is for the power terminals, not the mounting rail. Power connection is bolted or via ring lugs up to 185 mm². Control circuit uses push-in terminals for 0.2-2.5 mm² wire. Tightening torque for power is 18 N·m. The grey housing size: 193 mm deep, 108 mm wide, 193 mm tall. IP2X with shrouds on the front face. Overvoltage category III. Associated fuse recommendations: 250 A aM or 400 A gG at 400 V, or UL Type J at ≤600 V.","metaTitle":"Schneider TeSys Giga LC1G225KUEN Contactor, 110 kW at 400 V","metaDescription":"Active 3-pole contactor from TeSys Giga series. Rated 110 kW at 400 V AC-3e, coil 100-250 V AC/DC. Mechanical durability 8 Mcycles. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"7.6 in (193 mm)","Range":"TeSys","Width":"4.3 in (108 mm)","Height":"7.6 in (193 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","Motor power kW":"55 kW at 230 V AC 50/60 Hz (AC-3e) 110 kW at 400 V AC 50/60 Hz (AC-3e) 110 kW at 415 V AC 50/60 Hz (AC-3e) 132 kW at 440 V AC 50/60 Hz (AC-3e) 132 kW at 500 V AC 50/60 Hz (AC-3e) 160 kW at 690 V AC 50/60 Hz (AC-3e) 132 kW at 1000 V AC 50/60 Hz (AC-3e) 55 kW at 230 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 132 kW at 440 V AC 50/60 Hz (AC-3) 132 kW at 500 V AC 50/60 Hz (AC-3) 160 kW at 690 V AC 50/60 Hz (AC-3) 132 kW at 1000 V AC 50/60 Hz (AC-3) 55 kW at 230 V AC 50/60 Hz (AC-4) 110 kW at 400 V AC 50/60 Hz (AC-4) 110 kW at 415 V AC 50/60 Hz (AC-4) 129 kW at 440 V AC 50/60 Hz (AC-4) 132 kW at 500 V AC 50/60 Hz (AC-4) 132 kW at 690 V AC 50/60 Hz (AC-4) 110 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.4 in (35 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00015 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"159.3 lbf.in (18 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"250 A aM at 200 A aM at 400 A gG at 400 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"380 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"2050 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"2720 A at 440 V","Maximum Horse Power Rating":"60 hp at 200/208 V 60 Hz 75 hp at 230/240 V 60 Hz 150 hp at 460/480 V 60 Hz 150 hp at 575/600 V 60 Hz","Power dissipation per pole":"20 W AC-1 - Ith 330 A 8 W AC-3 - Ith 225 A","[Uc] control circuit voltage":"100...250 V AC 50/60 Hz 100...250 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"330 A (at 225 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"540 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"7.8 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"1.8 kA - 10 s 1.0 kA - 30 s 0.85 kA - 1 min 0.56 kA - 3 min 0.44 kA - 10 min","[Ith] conventional free air thermal current":"330 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$318.77","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/46ac3abe631ae2c273ef50f0c970a124.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G225KUEN/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for motor control?","answer":"It switches 110 kW at 400 V AC-3e, 110 kW at 400 V AC-3, and up to 160 kW at 690 V AC-3e. The coil accepts 100-250 V AC or DC."},{"question":"What compliance documentation does Schneider provide for this contactor?","answer":"It conforms to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1, among others. RoHS and REACH declarations are available from Schneider."},{"question":"What colour is the LC1G225KUEN?","answer":"Dark grey housing."},{"question":"What is the depth of this contactor?","answer":"193 mm (7.6 in)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G225KUEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G225KUEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}