{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G265XXEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G265XXEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G265XXEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G265XXEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys Giga LC1G265XXEN, 3-pole contactor, 265 A AC-3, 200 kW at 690 V, 3 NO + 1 NO + 1 NC, dark grey.","salesMarkdown":"The Schneider TeSys Giga LC1G265XXEN is a 3-pole power contactor rated for motor switching and general power control. Its headline AC-3 rating of 265 A translates to 132 kW at 400 V and 200 kW at 690 V — the numbers that decide whether it carries your motor load through the duty cycle. The AC-3e rating (optimized for energy-efficient motors) mirrors the same power figures, so it handles modern IE3/IE4 machines without derating. AC-4 duty (plugging, inching) drops to 132 kW at 400 V; that's the figure to watch if your application reverses or jogs the load frequently. Built into the TeSys Giga family, this contactor uses a built-in bidirectional peak-limiting coil circuit that cuts inrush draw to 350 W DC — useful when the control transformer is already loaded with PLCs and relays. For AC-1 resistive loads, the thermal current (Ith) is 385 A with 20 W dissipation per pole. Mounts on a plate (not DIN rail — this is a bolted-frame contactor sized for a 45 mm pole pitch). Power connections accept bar busbars up to 32 x 10 mm or ring lugs up to 185 mm²; control wiring uses push-in terminals for 0.2–2.5 mm² solid or ferrule-ended stranded. The 226 mm depth and 140 mm width mean you need a clear 8.9 x 5.5 inch footprint on the backplate, plus swing clearance for the arc chutes. Auxiliary contacts are built in: 1 NO + 1 NC. That covers feedback to the PLC and a seal-in circuit without an add-on block. For more aux contacts or a mechanical interlock, the TeSys Giga range uses clip-on side-mounts — verify the order code suffix if you need extra poles. Certified to EN/IEC 60947-4-1 (contactor/motor starter), EN/IEC 60947-5-1 (control circuit devices), UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1/5-1. Overvoltage category III. Protective treatment TH (tropicalized — resists humidity and condensation). Safety reliability data is published: B10d = 400,000 cycles at nominal load per EN/ISO 13849-1, and 3,000,000 cycles with mechanical load only.","metaTitle":"Schneider TeSys Giga LC1G265XXEN Contactor, 265 A AC-3, 200","metaDescription":"Schneider TeSys Giga LC1G265XXEN 3-pole contactor. 265 A AC-3, 200 kW at 690 V. Active production. IEC/UL/CSA. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"8.9 in (226 mm)","Range":"TeSys","Width":"5.5 in (140 mm)","title":"LC1G265XXEN","Height":"8.9 in (225 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1","description":"High power contactor,TeSys Giga,3P(3NO),AC-3 <=440V 265A,standard version,600V AC/DC coil","Motor power kW":"75 kW at 230 V AC 50/60 Hz (AC-3e) 132 kW at 400 V AC 50/60 Hz (AC-3e) 132 kW at 415 V AC 50/60 Hz (AC-3e) 160 kW at 440 V AC 50/60 Hz (AC-3e) 160 kW at 500 V AC 50/60 Hz (AC-3e) 200 kW at 690 V AC 50/60 Hz (AC-3e) 160 kW at 1000 V AC 50/60 Hz (AC-3e) 75 kW at 230 V AC 50/60 Hz (AC-3) 132 kW at 400 V AC 50/60 Hz (AC-3) 132 kW at 415 V AC 50/60 Hz (AC-3) 160 kW at 440 V AC 50/60 Hz (AC-3) 160 kW at 500 V AC 50/60 Hz (AC-3) 200 kW at 690 V AC 50/60 Hz (AC-3) 160 kW at 1000 V AC 50/60 Hz (AC-3) 75 kW at 230 V AC 50/60 Hz (AC-4) 132 kW at 400 V AC 50/60 Hz (AC-4) 132 kW at 415 V AC 50/60 Hz (AC-4) 150 kW at 440 V AC 50/60 Hz (AC-4) 160 kW at 500 V AC 50/60 Hz (AC-4) 160 kW at 690 V AC 50/60 Hz (AC-4) 160 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.8 in (45 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.000144 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"309.8 lbf.in (35 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"315 A aM at 250 A aM at 400 A gG at 450 A UL Type J at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"350 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Power circuit: bolted connection Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"2380 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"3320 A at 440 V","Maximum Horse Power Rating":"75 hp at 200/208 V 60 Hz 100 hp at 230/240 V 60 Hz 200 hp at 460/480 V 60 Hz 200 hp at 575/600 V 60 Hz","Power dissipation per pole":"20 W AC-1 - Ith 385 A 11 W AC-3 - Ith 265 A","[Uc] control circuit voltage":"600 V AC 50/60 Hz 600 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"385 A (at 265 A (at <140 °F (60 °C)) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"550 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"9 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2.2 kA - 10 s 1.23 kA - 30 s 0.95 kA - 1 min 0.62 kA - 3 min 0.48 kA - 10 min","[Ith] conventional free air thermal current":"385 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,500.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8842eeb8a6a872c03bd3096534381311.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G265XXEN/high-power-contactortesys-giga3p3noac3-440v-265astandard-version600v-ac-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative within the same family?","answer":"Within the TeSys Giga LC1G family, the power pole and mounting footprint are shared across current ratings. A lower or higher AC-3 current rating (e.g., LC1G205 or LC1G330) uses the same 45 mm pitch and bolted busbar connections. The deciding factor is your motor full-load current and available control voltage — the coil and aux block are order-code-suffix options, not a different frame."},{"question":"What compliance documentation is available?","answer":"The contactor carries IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1 certifications. Protective treatment is TH (tropicalized). Safety data per EN/ISO 13849-1 is published for B10d values. RoHS/REACH declarations are standard for Schneider TeSys products but are not itemized in this listing — request them with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G265XXEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G265XXEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}