{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G3304EHEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G3304EHEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G3304EHEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G3304EHEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G3304EHEN, 4-pole contactor, 48-130 V AC/DC control, 330 A AC-3 conventional thermal current.","salesMarkdown":"## Contactor ratings and duty The LC1G3304EHEN is a 4-pole TeSys Giga contactor from Schneider Electric, rated for AC-3 motor switching with a conventional thermal current of 330 A. Its control circuit accepts 48–130 V AC or DC, a wide-span coil that simplifies stocking across mixed-voltage plants. Mechanical durability hits 8 million cycles, and the coil incorporates built-in bidirectional peak limiting, so it handles furnace damper cycling or conveyor indexing without external suppression. Operating time runs 40–70 ms closing, 15–50 ms opening – fast enough for sequence interlocks, with a maximum operating rate of 600 cycles per hour in AC-3 duty. ## Mounting and power wiring Mounts on a plate (not DIN rail), sized at 8.9 in depth, 7.3 in width, 8.9 in height. Connection pitch is 1.8 in on the power side, accepting bar or ring lugs up to 185 mm². Tightening torque for power terminals is 35 Nm. Control circuit uses push-in terminals for 0.2–2.5 mm² stranded or solid, keeping wiring quick on the panel line. Power dissipation per pole is 30 W in AC-1 (440 A Ith) and 16 W in AC-3 (330 A Ith). ## Coil inrush and control limits DC inrush power is 695 W. Dropout occurs between 0.1 Uc max and 0.45 Uc min. Auxiliary contacts are 1 NO + 1 NC, enough for a feedback loop to the PLC without an add-on block. ## Production status and compliance Standards compliance covers EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and UL 60335-1/2-40 for appliance applications. Overvoltage category III, pollution degree data not in this summary.","metaTitle":"LC1G3304EHEN TeSys Giga 4P Contactor, 48-130VAC/DC, 330A AC-","metaDescription":"LC1G3304EHEN TeSys Giga 4-pole contactor, active production. 330A AC-3 conventional thermal current, 48-130VAC/DC coil, 1000V insulation. Compliance: IEC, UL, CSA. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Dark grey","Depth":"8.9 in (226 mm)","Range":"TeSys","Width":"7.3 in (185 mm)","Height":"8.9 in (225 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.8 in (45 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.000144 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5","Contactor application":"Power switching","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A aM at 250 A aM at 500 A gG at 600 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1","inrush power in W (DC)":"695 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"2940 A at 440 V","Pole contact composition":"4 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"3830 A at 440 V","Power dissipation per pole":"30 W AC-1 - Ith 440 A 16 W AC-3 - Ith 330 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"330 A (at 440 A (at <104 °F (40 °C)) at <= 1000 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"780 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"7.8 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2.65 kA - 10 s 1.8 kA - 30 s 1.3 kA - 1 min 0.9 kA - 3 min 0.75 kA - 10 min","[Ith] conventional free air thermal current":"440 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/40f89a62fedca12d0bb29c50081c1379.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC1G3304EHEN/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does the LC1G3304EHEN meet?","answer":"It is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and UL 60335-1/2-40."},{"question":"What is the control voltage range for this contactor?","answer":"The coil accepts 48–130 V AC at 50/60 Hz or 48–130 V DC."},{"question":"How many auxiliary contacts are included?","answer":"It comes with 1 normally open and 1 normally closed auxiliary contact."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G3304EHEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G3304EHEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}