{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G3304EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G3304EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G3304EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G3304EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LC1G3304EHES207N, 4-pole contactor, 160 kW at 400 V AC-3e, 48-130 V AC/DC coil, plate mount.","salesMarkdown":"The Schneider Electric LC1G3304EHES207N is a TeSys Giga 4-pole contactor rated for 160 kW at 400 V AC in AC-3e duty — that's the motor-switching rating that governs real-world pump, fan, and conveyor loads. It also carries AC-1 (resistive), AC-4 (plugging/inching), and DC-1/DC-3/DC-5 ratings, so it covers resistive heating banks and DC loads too. Drop-out threshold is 0.1 to 0.45 Uc, so it releases reliably on a sagging control bus. Plate-mounted, not DIN-rail — the 225 mm depth and 140 mm width need a backplate or sub-panel. Power connections are bolted: bar up to 32 x 10 mm busbar, or lugs up to 185 mm². Tightening torque on the power terminals is 35 N·m — that's substantial; use a torque wrench. Mechanical durability is 8 million cycles. The maximum operating rate is 500 cycles/hour in AC-3/AC-3e duty, 300 in AC-1, 150 in AC-4. For safety circuits, the B10d value is 400,000 cycles at nominal load per EN/ISO 13849-1. Certified to EN/IEC 60947-4-1 and -5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1 and -5-1, plus UL 60335-1 and UL 60335-2-40 Annex JJ for appliance applications. Overvoltage category III. Protective treatment TH (tropicalized).","metaTitle":"TeSys Giga LC1G3304EHES207N Contactor, 160 kW at 400 V AC-3e","metaDescription":"Schneider Electric TeSys Giga LC1G3304EHES207N contactor. 160 kW at 400 V AC-3e, 4-pole, 48-130 V AC/DC coil. UL/CSA/IEC. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"225 mm","Range":"TeSys","Width":"140 mm","title":"LC1G3304EHES207N","Colour":"Dark grey","Height":"225 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","description":"High power contactor,TeSys Giga S207,4P(4NO),AC-3 <=440V 330A,standard version,48-130V AC/DC wide band coil","Motor power hp":"100 hp at 200/208 V 60 Hz 125 hp at 230/240 V 60 Hz 250 hp at 460/480 V 60 Hz 300 hp at 575/600 V 60 Hz","Motor power kW":"90 kW at 230 V AC 50/60 Hz (AC-3e) 160 kW at 400 V AC 50/60 Hz (AC-3e) 160 kW at 415 V AC 50/60 Hz (AC-3e) 185 kW at 440 V AC 50/60 Hz (AC-3e) 200 kW at 500 V AC 50/60 Hz (AC-3e) 220 kW at 690 V AC 50/60 Hz (AC-3e) 185 kW at 1000 V AC 50/60 Hz (AC-3e) 90 kW at 230 V AC 50/60 Hz (AC-3) 160 kW at 400 V AC 50/60 Hz (AC-3) 160 kW at 415 V AC 50/60 Hz (AC-3) 200 kW at 440 V AC 50/60 Hz (AC-3) 200 kW at 500 V AC 50/60 Hz (AC-3) 220 kW at 690 V AC 50/60 Hz (AC-3) 185 kW at 1000 V AC 50/60 Hz (AC-3) 90 kW at 230 V AC 50/60 Hz (AC-4) 160 kW at 400 V AC 50/60 Hz (AC-4) 160 kW at 415 V AC 50/60 Hz (AC-4) 185 kW at 440 V AC 50/60 Hz (AC-4) 200 kW at 500 V AC 50/60 Hz (AC-4) 220 kW at 690 V AC 50/60 Hz (AC-4) 185 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"45 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.000144 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"35 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"400 A aM at 250 A aM at 500 A gG at 600 A UL Type L at <= 600 V","Maximum operating rate":"300 cyc/h AC-1 500 cyc/h AC-3 500 cyc/h AC-3e 150 cyc/h AC-4","inrush power in W (DC)":"695 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"2940 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"3830 A at 440 V","Power dissipation per pole":"30 W AC-1 - Ith 440 A 16 W AC-3 - Ith 330 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"440 A (at 330 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"780 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"7.8 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2.65 kA - 10 s 1.8 kA - 30 s 1.3 kA - 1 min 0.9 kA - 3 min 0.75 kA - 10 min","[Ith] conventional free air thermal current":"440 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/40f89a62fedca12d0bb29c50081c1379.pdf","sourceUrl":"https://www.se.com/ae/en/product/LC1G3304EHES207N/high-power-contactortesys-giga-s2074p4noac3-440v-330astandard-version48130v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"In AC-3e duty, it handles 160 kW at 400 V AC, 160 kW at 415 V, 200 kW at 500 V, and 220 kW at 690 V. In horsepower terms: 250 hp at 460/480 V 60 Hz and 300 hp at 575/600 V 60 Hz."},{"question":"What control voltage does this contactor use?","answer":"The coil accepts 48-130 V AC 50/60 Hz or 48-130 V DC, with built-in peak limiting. Drop-out occurs between 0.1 and 0.45 Uc."},{"question":"What compliance documentation is available for this part?","answer":"It is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, UL 60335-1, and UL 60335-2-40 Annex JJ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G3304EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G3304EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}