{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G400EHES207N","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G400EHES207N","canonicalUrl":"https://aoctrl.com/schneider/LC1G400EHES207N","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G400EHES207N","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga series, LC1G400EHES207N, 3-pole contactor, 200 kW at 400 V AC-3e, 48-130 V AC/DC coil, plate mount.","salesMarkdown":"The Schneider Electric TeSys Giga LC1G400EHES207N is a 3-pole power contactor rated for heavy motor switching. In AC-3e duty — the standard for squirrel-cage motor starting — it handles 200 kW at 400 V AC 50/60 Hz, and scales up to 315 kW at 690 V. The same unit also carries AC-4 ratings for reversing or inching duty: 200 kW at 400 V, 315 kW at 690 V. That means it meets the motor load where it lives, without oversizing for the occasional plug-reverse cycle. The control circuit accepts 48-130 V AC or DC, with a built-in bidirectional peak-limiting coil technology that suppresses inrush and holds at 760 W peak. Drop-out threshold sits between 0.1 and 0.45 Uc, so it releases cleanly on a sagging control bus without chatter. ## Where it fits — panel and line integration This contactor mounts to a plate, not a DIN rail — the 225 x 226 x 140 mm envelope and 45 mm pole pitch are sized for bolted busbar or lug-ring connections. Power terminals accept bar up to 32 x 10 mm or lugs up to 185 mm². Control wiring uses push-in spring terminals on 0.2-2.5 mm² flexible or solid wire. Tightening torque on the power connections is 35 N.m — a calibrated wrench is the right tool, not an impact gun. IP2X on the front face with shrouds keeps fingers out per IEC 60529. The TH protective treatment handles damp environments. Mechanical durability is 8 million cycles; maximum operating rate hits 600 cycles/hour in AC-3 or AC-3e, 150 in AC-4. That's a contactor built for a high-duty conveyor line or a pump station cycling multiple times per minute. ## Standards and compliance — what the approvals mean This contactor carries approvals across the major global regimes: EN/IEC 60947-4-1 and 60947-5-1 for contactors and control-circuit devices, UL 60947-4-1 and CSA C22.2 No 60947-4-1 for North American installations, plus JIS C8201 for Japan. It also meets IEC 60335-1 Clause 30.2 and UL 60335-1 for appliance safety — relevant if the contactor ends up inside a packaged machine that needs a household-appliance-level glow-wire test. Overvoltage category III means it is rated for fixed-installation distribution-level surges. For safety-related circuits, the B10d values under EN/ISO 13849-1 are 400,000 cycles at nominal load and 3,000,000 cycles at mechanical load — useful data if the contactor is part of a monitored safety chain and you need to calculate the PFHd.","metaTitle":"Schneider TeSys Giga LC1G400EHES207N Contactor, 200 kW at 40","metaDescription":"Schneider Electric TeSys Giga LC1G400EHES207N 3-pole contactor. 200 kW at 400 V AC-3e, 48-130 V AC/DC coil. Current production, UL/CSA/IEC certified. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"226 mm","Range":"TeSys","Width":"140 mm","title":"LC1G400EHES207N","Colour":"Dark grey","Height":"225 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ","description":"High power contactor,TeSys Giga S207,3P(3NO),AC-3 <=440V 400A,standard version,48-130V AC/DC wide band coil","Motor power hp":"125 hp at 200/208 V 60 Hz 150 hp at 230/240 V 60 Hz 300 hp at 460/480 V 60 Hz 400 hp at 575/600 V 60 Hz","Motor power kW":"110 kW at 230 V AC 50/60 Hz (AC-3e) 200 kW at 400 V AC 50/60 Hz (AC-3e) 200 kW at 415 V AC 50/60 Hz (AC-3e) 250 kW at 440 V AC 50/60 Hz (AC-3e) 250 kW at 500 V AC 50/60 Hz (AC-3e) 315 kW at 690 V AC 50/60 Hz (AC-3e) 220 kW at 1000 V AC 50/60 Hz (AC-3e) 110 kW at 230 V AC 50/60 Hz (AC-3) 200 kW at 400 V AC 50/60 Hz (AC-3) 200 kW at 415 V AC 50/60 Hz (AC-3) 250 kW at 440 V AC 50/60 Hz (AC-3) 250 kW at 500 V AC 50/60 Hz (AC-3) 315 kW at 690 V AC 50/60 Hz (AC-3) 220 kW at 1000 V AC 50/60 Hz (AC-3) 110 kW at 230 V AC 50/60 Hz (AC-4) 200 kW at 400 V AC 50/60 Hz (AC-4) 200 kW at 415 V AC 50/60 Hz (AC-4) 220 kW at 440 V AC 50/60 Hz (AC-4) 250 kW at 500 V AC 50/60 Hz (AC-4) 315 kW at 690 V AC 50/60 Hz (AC-4) 220 kW at 1000 V AC 50/60 Hz (AC-4)","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"45 mm","Mounting support":"Plate","Range of product":"TeSys Giga","Average impedance":"0.0001 Ohm","Device short name":"LC1G","Poles description":"3P","Tightening torque":"35 N.m","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8b AC-8a DC-1 DC-3 DC-5","Contactor application":"Power switching Motor control","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Associated fuse rating":"500 A aM at 315 A aM at 630 A gG at 600 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4","inrush power in W (DC)":"760 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5...1.0 mm² with cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106","Rated breaking capacity":"3480 A at 440 V","Pole contact composition":"3 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"5090 A at 440 V","Power dissipation per pole":"30 W AC-1 - Ith 550 A 16 W AC-3 - Ith 400 A","[Uc] control circuit voltage":"48...130 V AC 50/60 Hz 48...130 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)","[Ie] rated operational current":"550 A (at 400 A (at <60 °C) at <= 440 V AC-3","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"965 VA","Ambient air temperature for storage":"-60...80 °C","hold-in power consumption in W (DC)":"7.8 W","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"3.6 kA - 10 s 2.4 kA - 30 s 1.7 kA - 1 min 1.2 kA - 3 min 1.0 kA - 10 min","[Ith] conventional free air thermal current":"550 A (at 40 °C)","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1909e16e3b77460b4c587fb01c435692.pdf","sourceUrl":"https://www.se.com/be/en/product/LC1G400EHES207N/high-power-contactortesys-giga-s2073p3noac3-440v-400astandard-version48130v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What are the key motor power ratings for this contactor?","answer":"In AC-3e duty it handles 200 kW at 400 V, 315 kW at 690 V, and 220 kW at 1000 V AC. In AC-4 reversing duty the ratings are 200 kW at 400 V and 315 kW at 690 V. For North American voltages, it is rated 300 hp at 460/480 V 60 Hz."},{"question":"What control voltage does this contactor use?","answer":"The coil accepts 48-130 V AC 50/60 Hz or 48-130 V DC. It includes built-in bidirectional peak limiting to manage inrush."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets IEC 60335-1 Clause 30.2 and UL 60335-1 for appliance safety. Overvoltage category III."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G400EHES207N","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G400EHES207N when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}