{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC1G5004LSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC1G5004LSEN","canonicalUrl":"https://aoctrl.com/schneider/LC1G5004LSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LC1G5004LSEN","rawCanonicalId":null},"summary":{"shortDescription":"TeSys Giga LC1G5004LSEN 4-pole contactor, 700A AC-1 / 500A AC-3, 200-500V AC/DC coil, built-in peak limiting.","salesMarkdown":"## Integrator's note: what this contactor brings to the panel The TeSys Giga LC1G5004LSEN is a 4-pole power contactor rated 700 A in AC-1 (resistive) and 500 A in AC-3 (motor) duty, with a control voltage range of 200–500 V AC or DC. That dual-voltage coil, combined with built-in bidirectional peak limiting, removes the need for an external MOV or RC snubber — one less component to fail and one less wiring point to check during commissioning. Mechanical durability is 8 million cycles, and the contactor stays closed under vibration up to 4 gn. For a concurrently maintainable installation, that means fewer unplanned swaps over the facility's life. Operating times are 40–70 ms closing and 15–50 ms opening — fast enough for most transfer schemes, but verify coordination if your logic demands sub-cycle break-before-make. ## Mounting and wiring — panel integration checklist Mounts on a plate (plate mounting specified). Overall footprint: 8.9 in deep (226 mm), 8.9 in high (225 mm), 7.3 in wide (185 mm). Connection pitch is 45 mm — verify spacing if replacing an existing contactor in a tight layout. Power circuit terminals accept bar (2 x 32×10 mm cross-section) or ring lugs up to 185 mm². Tightening torque 35 N·m (309.8 lbf·in). Strip to 8–10 mm; spring-cage retention eliminates screw torque verification. IP2X front face achieved with supplied shrouds — fit them before energizing. Auxiliary contacts: 1 NO + 1 NC integrated. Safety reliability B10d = 400,000 cycles at nominal load per EN/ISO 13849-1.","metaTitle":"TeSys Giga LC1G5004LSEN Contactor, 4-Pole, 700A AC-1","metaDescription":"Active production 4-pole contactor from TeSys Giga range. Rated 700A AC-1 / 500A AC-3. Built-in peak limiting coil. Meets EN/IEC 60947-4-1, UL, CSA. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Color":"Dark grey","Depth":"8.9 in (226 mm)","Range":"TeSys","Width":"7.3 in (185 mm)","title":"LC1G5004LSEN","Height":"8.9 in (225 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ","description":"Contactor, high power, TeSys Giga, 4P(4NO), AC-1, <=440V 700A, standard version, 200-500V AC/DC wide band coil","Operating time":"40...70 ms closing 15...50 ms opening","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Connection pitch":"1.8 in (45 mm)","Mounting Support":"Plate","Range of Product":"TeSys Giga","Average impedance":"0.00008 Ohm","Device short name":"LC1G","Poles description":"4P","Tightening torque":"309.8 lbf.in (35 N.m)","Compatibility code":"LC1G","Overvoltage category":"III","Protective treatment":"TH","Utilisation category":"AC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5","Contactor application":"Power switching","Mechanical durability":"8 Mcycles","Mechanical robustness":"Vibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed","Nbr. of units in pkg.":"1","Associated fuse rating":"500 A aM at 400 A aM at 800 A gG at 600 A UL Type L at <= 600 V","Maximum operating rate":"600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1","inrush power in W (DC)":"300 W","Connections - terminals":"Power circuit: bar 2 - busbar cross section: 32 x 10 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Control circuit: push-in 1 0.0003...0.004 in² (0.2...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004...0.004 in² (0.25...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008...0.002 in² (0.5...1.0 mm²) with cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: solid stranded without cable end Control circuit: push-in 0.001...0.004 in² (0.75...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106","Rated breaking capacity":"4600 A at 440 V","Pole contact composition":"4 NO","Safety reliability level":"B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1 B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"5090 A at 440 V","Power dissipation per pole":"40 W AC-1 - Ith 700 A 20 W AC-3 - Ith 500 A","[Uc] control circuit voltage":"200...500 V AC 50/60 Hz 200...500 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"1000 V","Control circuit voltage limits":"Operational: 0.8 Uc Min...1.1 Uc Max (at Drop-out: 0.1 Uc Max...0.45 Uc Min (at <140 °F (60 °C))","[Ie] rated operational current":"500 A (at 700 A (at <104 °F (40 °C)) at <= 1000 V AC-1","[Ue] rated operational voltage":"<= 460 V DC","inrush power in VA (50/60 Hz, AC)":"535 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","hold-in power consumption in W (DC)":"8.6 W","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"4.0 kA - 10 s 2.8 kA - 30 s 2.2 kA - 1 min 1.5 kA - 3 min 1.2 kA - 10 min","[Ith] conventional free air thermal current":"700 A (at 104 °F (40 °C))","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c1f98a26d6c7daceb546a2a487ac2bb.pdf","sourceUrl":"https://www.se.com/us/en/product/LC1G5004LSEN/contactor-high-power-tesys-giga-4p4no-ac1-440v-700a-standard-version-200500v-ac-dc-wide-band-coil/"},"ai":{"faq":[{"question":"What is the listed color of LC1G5004LSEN?","answer":"Dark grey."},{"question":"What is the depth of LC1G5004LSEN?","answer":"8.9 in (226 mm)."},{"question":"What compliance standards does this contactor meet?","answer":"It meets EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, UL 60335-1, and UL 60335-2-40 Annex JJ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC1G5004LSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC1G5004LSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}